Literature DB >> 27120192

PSI kinematic versus non-PSI mechanical alignment in total knee arthroplasty: a prospective, randomized study.

Tilman Calliess1, Kamil Bauer1, Christina Stukenborg-Colsman1, Henning Windhagen1, Stefan Budde1, Max Ettinger2.   

Abstract

PURPOSE: Kinematic alignment in TKA is supposed to restore function by aligning the components to the premorbid flexion-extension axis instead of altering the joint line and natural kinematic axes of the knee. The purpose of this study was to compare mechanically aligned TKA to kinematic alignment.
METHODS: In this study, 200 patients underwent TKA and were randomly assigned to 2 groups: 100 TKAs were performed using kinematic alignment with custom-made cutting guides in order to complete cruciate-retaining TKA; the other 100 patients underwent TKA that was manually performed using mechanical alignment. The WOMAC and combined Knee Society Score (KSS), as well as radiological alignment, were determined as outcome parameters at the 12-month endpoint.
RESULTS: WOMAC and KSS significantly improved in both groups. There was a significant difference in both scores between groups in favour of kinematic alignment. Although the kinematic alignment group demonstrated significantly better overall results, more outliers with poor outcomes were also seen in this group. A correlation between post-operative alignment deviation from the initial plan and poor outcomes was also noted. The most important finding of this study is that applying kinematic alignment in TKA achieves comparable results to mechanical alignment in TKA. This study also shows that restoring the premorbid flexion-extension axis of the knee joint leads to better overall functional results.
CONCLUSION: Kinematic alignment is a favourable technique for TKA. CLINICAL RELEVANCE: The kinematic alignment idea might be a considerable alternative to mechanical alignment in the future. LEVEL OF EVIDENCE: II.

Entities:  

Keywords:  Kinematic alignment; PSI; Shape match; TKA; TKR; Total knee arthroplasty; Total knee replacement

Mesh:

Year:  2016        PMID: 27120192     DOI: 10.1007/s00167-016-4136-8

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  25 in total

1.  Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality.

Authors:  Donald G Eckhoff; Joel M Bach; Victor M Spitzer; Karl D Reinig; Michelle M Bagur; Todd H Baldini; Nicolas M P Flannery
Journal:  J Bone Joint Surg Am       Date:  2005       Impact factor: 5.284

Review 2.  Accuracy of patient-specific instrumentation compared with conventional instrumentation in total knee arthroplasty.

Authors:  Jin Jiang; Xin Kang; Qiao Lin; Yuanjun Teng; Liping An; Jingling Ma; Jing Wang; Yayi Xia
Journal:  Orthopedics       Date:  2015-04       Impact factor: 1.390

3.  Should we aim at undercorrection when doing a total knee arthroplasty?

Authors:  T Luyckx; F Vanhoorebeeck; J Bellemans
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-07-24       Impact factor: 4.342

Review 4.  [Kinematic alignment in total knee arthroplasty : Concept, evidence base and limitations].

Authors:  T Calliess; M Ettinger; C Stukenborg-Colsmann; H Windhagen
Journal:  Orthopade       Date:  2015-04       Impact factor: 1.087

5.  The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus.

Authors:  Johan Bellemans; William Colyn; Hilde Vandenneucker; Jan Victor
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

6.  A randomised controlled trial of kinematically and mechanically aligned total knee replacements: two-year clinical results.

Authors:  H G Dossett; N A Estrada; G J Swartz; G W LeFevre; B G Kwasman
Journal:  Bone Joint J       Date:  2014-07       Impact factor: 5.082

7.  Residual varus alignment does not compromise results of TKAs in patients with preoperative varus.

Authors:  Robert A Magnussen; Florent Weppe; Guillaume Demey; Elvire Servien; Sébastien Lustig
Journal:  Clin Orthop Relat Res       Date:  2011-07-26       Impact factor: 4.176

8.  Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement.

Authors:  Georg Matziolis; Joern Adam; Carsten Perka
Journal:  Arch Orthop Trauma Surg       Date:  2010-02-18       Impact factor: 3.067

9.  Comparison between patient-specific instruments and conventional instruments and computer navigation in total knee arthroplasty: a randomized controlled trial.

Authors:  Chun Hoi Yan; Kwong Yuen Chiu; Fu Yuen Ng; Ping Keung Chan; Christian Xinshuo Fang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-13       Impact factor: 4.342

10.  Accurate alignment and high function after kinematically aligned TKA performed with generic instruments.

Authors:  Stephen M Howell; Stelios Papadopoulos; Kyle T Kuznik; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-15       Impact factor: 4.342

View more
  38 in total

1.  Is There a Force Target That Predicts Early Patient-reported Outcomes After Kinematically Aligned TKA?

Authors:  Trevor J Shelton; Stephen M Howell; Maury L Hull
Journal:  Clin Orthop Relat Res       Date:  2019-05       Impact factor: 4.176

2.  Kinematic versus mechanical alignment for primary total knee replacement: A systematic review and meta-analysis.

Authors:  Joshua Xu; Jacob Y Cao; Jason K Luong; Jonathan J Negus
Journal:  J Orthop       Date:  2019-02-28

3.  Kinematically aligned total knee arthroplasty: alternative standardized technique?

Authors:  Tomoyuki Matsumoto; Koji Takayama; Kazunari Ishida; Shinya Hayashi; Shingo Hashimoto; Ryosuke Kuroda
Journal:  Ann Transl Med       Date:  2017-05

4.  Kinematic alignment more closely restores the groove location and the sulcus angle of the native trochlea than mechanical alignment: implications for prosthetic design.

Authors:  Rocio Lozano; Valentina Campanelli; Stephen Howell; Maury Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-24       Impact factor: 4.342

Review 5.  [Robotics-mechanical bridge between imaging and patient].

Authors:  M Ettinger; P Savov; T Calliess; H Windhagen
Journal:  Orthopade       Date:  2018-10       Impact factor: 1.087

6.  Kinematically aligned TKA restores physiological patellofemoral biomechanics in the sagittal plane during a deep knee bend.

Authors:  Stephanie Nicolet-Petersen; Augustine Saiz; Trevor Shelton; Stephen Howell; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-05-30       Impact factor: 4.342

7.  What mechanisms are associated with tibial component failure after kinematically-aligned total knee arthroplasty?

Authors:  Alexander J Nedopil; Stephen M Howell; Maury L Hull
Journal:  Int Orthop       Date:  2017-05-11       Impact factor: 3.075

Review 8.  Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty.

Authors:  Yong Seuk Lee; Stephen M Howell; Ye-Yeon Won; O-Sung Lee; Seung Hoon Lee; Hamed Vahedi; Seow Hui Teo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

9.  What clinical characteristics and radiographic parameters are associated with patellofemoral instability after kinematically aligned total knee arthroplasty?

Authors:  Alexander J Nedopil; Stephen M Howell; Maury L Hull
Journal:  Int Orthop       Date:  2016-09-12       Impact factor: 3.075

10.  Kinematically aligned total knee arthroplasty reproduces native patellofemoral biomechanics during deep knee flexion.

Authors:  In Jun Koh; Il Jung Park; Charles C Lin; Nilay A Patel; Christen E Chalmers; Mauro Maniglio; Michelle H McGarry; Thay Q Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-28       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.