Literature DB >> 25056740

Should we aim at undercorrection when doing a total knee arthroplasty?

T Luyckx1, F Vanhoorebeeck, J Bellemans.   

Abstract

PURPOSE: Restoration of neutral mechanical alignment is traditionally considered as one of the prerequisites for successful total knee replacement. The purpose of this study was to investigate whether a certain bias towards undercorrection exists with conventional total knee arthroplasty (TKA) instruments.
METHODS: A cohort of 456 consecutive patients, who underwent the same standardised TKA with restoration of neutral mechanical alignment as target, was studied. Based on the preoperative alignment, patients were stratified into three categories: valgus, neutral and varus. Component and limb alignment were compared between these groups.
RESULTS: The mean post-operative hip-knee-ankle angle was -0.7° (SD 2.5) in valgus knees, 0.2° (SD 1.9) in neutral knees and 2.4° (SD 3.9) in varus knees (p < 0.001). About 39.8% of the varus knees remained in >3° of varus post-operative and 20.2% of the valgus knees remained in <-3° of valgus. A systematic unintentional undercorrection was noted in varus knees, which was proportional to the preoperative varus deformity and which was caused by varus positioning of both the femoral and tibial components. In valgus knees, the undercorrection was caused almost exclusively by valgus bias of the femoral component's position.
CONCLUSION: This study showed that conventional TKA instruments are associated with a systematic unintentional bias towards undercorrection of the pre-existing deformity. The clinical relevance of this study is that intentionally aiming at slight undercorrection of the deformity may lead to excessive undercorrection in reality in case the surgeon does not recognise the automatic bias that already exists with standard instruments. LEVEL OF EVIDENCE: Therapeutic study, Level III.

Entities:  

Mesh:

Year:  2014        PMID: 25056740     DOI: 10.1007/s00167-014-3185-0

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  12 in total

1.  Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements.

Authors:  Sebastien Parratte; Mark W Pagnano; Robert T Trousdale; Daniel J Berry
Journal:  J Bone Joint Surg Am       Date:  2010-09-15       Impact factor: 5.284

2.  Pitfalls in determining knee alignment: a radiographic cadaver study.

Authors:  R W Brouwer; T S C Jakma; K H Brouwer; J A N Verhaar
Journal:  J Knee Surg       Date:  2007-07       Impact factor: 2.757

3.  Effective measurement of knee alignment using AP knee radiographs.

Authors:  Alexandra N Colebatch; Deborah J Hart; Guangju Zhai; F M Williams; Tim D Spector; Nigel K Arden
Journal:  Knee       Date:  2008-09-14       Impact factor: 2.199

4.  Frontal plane knee alignment: a call for standardized measurement.

Authors:  T Derek V Cooke; Elizabeth A Sled; R Allan Scudamore
Journal:  J Rheumatol       Date:  2007-09       Impact factor: 4.666

5.  Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties.

Authors:  J H Lonner; M T Laird; S A Stuchin
Journal:  Clin Orthop Relat Res       Date:  1996-10       Impact factor: 4.176

6.  The effect of alignment and BMI on failure of total knee replacement.

Authors:  Merrill A Ritter; Kenneth E Davis; John B Meding; Jeffery L Pierson; Michael E Berend; Robert A Malinzak
Journal:  J Bone Joint Surg Am       Date:  2011-09-07       Impact factor: 5.284

7.  The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus.

Authors:  Johan Bellemans; William Colyn; Hilde Vandenneucker; Jan Victor
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

8.  Residual varus alignment does not compromise results of TKAs in patients with preoperative varus.

Authors:  Robert A Magnussen; Florent Weppe; Guillaume Demey; Elvire Servien; Sébastien Lustig
Journal:  Clin Orthop Relat Res       Date:  2011-07-26       Impact factor: 4.176

9.  Lower limb alignment in children: reference values based on a full-length standing radiograph.

Authors:  Sanjeev Sabharwal; Caixia Zhao; Michele Edgar
Journal:  J Pediatr Orthop       Date:  2008 Oct-Nov       Impact factor: 2.324

10.  Coronal alignment in total knee arthroplasty: just how important is it?

Authors:  David M Fang; Merrill A Ritter; Kenneth E Davis
Journal:  J Arthroplasty       Date:  2009-06-24       Impact factor: 4.757

View more
  7 in total

1.  Clinical usefulness of hindfoot assessment for total knee arthroplasty: persistent post-operative hindfoot pain and alignment in pre-existing severe knee deformity.

Authors:  Yoshinori Okamoto; Shuhei Otsuki; Tsuyoshi Jotoku; Mikio Nakajima; Masashi Neo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-07       Impact factor: 4.342

2.  Predicting knee rotation by the projection overlap of the proximal fibula and tibia in long-leg radiographs.

Authors:  Günther Maderbacher; Jens Schaumburger; Clemens Baier; Florian Zeman; Hans-Robert Springorum; Christian Dornia; Joachim Grifka; Armin Keshmiri
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-26       Impact factor: 4.342

3.  Effects of total knee arthroplasty on ankle alignment in patients with varus gonarthrosis: Do we sacrifice ankle to the knee?

Authors:  Sarper Gursu; Hakan Sofu; Peter Verdonk; Vedat Sahin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-21       Impact factor: 4.342

4.  PSI kinematic versus non-PSI mechanical alignment in total knee arthroplasty: a prospective, randomized study.

Authors:  Tilman Calliess; Kamil Bauer; Christina Stukenborg-Colsman; Henning Windhagen; Stefan Budde; Max Ettinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-27       Impact factor: 4.342

Review 5.  Kinematically Aligned Total Knee Arthroplasty with Patient-Specific Instrument.

Authors:  Kwang Kyoun Kim; Stephen M Howell; Ye Yeon Won
Journal:  Yonsei Med J       Date:  2020-03       Impact factor: 2.759

6.  Custom total knee arthroplasty facilitates restoration of constitutional coronal alignment.

Authors:  Michel P Bonnin; Lucas Beckers; Augustin Leon; Jules Chauveau; Jacobus H Müller; Carsten O Tibesku; Tarik Aït-Si-Selmi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-07-17       Impact factor: 4.114

7.  Slight femoral under-correction versus neutral alignment in total knee arthroplasty with preoperative varus knees: a comparative study.

Authors:  Kai Lei; Li-Ming Liu; Peng-Fei Yang; Ran Xiong; De-Jie Fu; Liu Yang; Lin Guo
Journal:  Arthroplasty       Date:  2022-01-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.