Literature DB >> 27117264

Cardiovascular magnetic resonance as a reliable alternative to cardiovascular computed tomography and transesophageal echocardiography for aortic annulus valve sizing.

Riccardo Faletti1, Marco Gatti2, Stefano Salizzoni3, Laura Bergamasco4, Rodolfo Bonamini4, Domenica Garabello5, Walter Grosso Marra6, Michele La Torre3, Mara Morello6, Simona Veglia5, Paolo Fonio2, Mauro Rinaldi3.   

Abstract

To assess the accuracy and reproducibly of cardiovascular magnetic resonance (CMR) in the measurement of the aortic annulus and in process of valve sizing as compared to intra-operative sizing, cardiovascular computed tomography (CCT) and transesophageal echocardiography (TEE). Retrospective study on 42 patients who underwent aortic valve replacement from September 2010 to September 2015, with available records of pre surgery annulus assessment by CMR, CCT and TEE and of peri-operative assessment. In CCT and CMR, the annular plane was considered a virtual ring formed by the lowest hinge points of the valvular attachments to the aorta. In TEE the annulus was measured at the base of leaflet insertion in the mid-esophageal long-axis view using the X-plane technique. Two double-blinded operators performed the assessments for each imaging technique. Intra-operative evaluation was performed using Hegar dilators. Continuous variables were studied with within-subject ANOVA, Bland-Altman (BA) plots, Wilcoxon's and Friedman's tests; trends were explored with scatter plots. Categorical variables were studied with Fisher's exact test. The intra- and inter-operator reliability was satisfying. There were no significant differences between the annulus dimensions measured by CMR and either one of the three references. Valve sizing for CoreValve by CMR had the same good agreement with CCT and TEE, with a 78 % match rate; for SAPIEN XT the agreement was slightly better (82 %) for CCT than for TEE (66 %). MR performs well when compared to the surgical reference of intra-operative sizing and stands up to the level of the most used imaging references (CCT and TEE).

Entities:  

Keywords:  Aortic stenosis; Cardiovascular computed tomography; Cardiovascular magnetic resonance; Transcatheter aortic valve implantation; Transesophageal echocardiography

Mesh:

Year:  2016        PMID: 27117264     DOI: 10.1007/s10554-016-0899-8

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  34 in total

1.  Aortic annulus sizing: echocardiographic versus computed tomography derived measurements in comparison with direct surgical sizing.

Authors:  Jörg Kempfert; Arnaud Van Linden; Lukas Lehmkuhl; Ardawan J Rastan; David Holzhey; Johannes Blumenstein; Friedrich W Mohr; Thomas Walther
Journal:  Eur J Cardiothorac Surg       Date:  2012-03-07       Impact factor: 4.191

2.  Transcatheter versus surgical aortic-valve replacement in high-risk patients.

Authors:  Craig R Smith; Martin B Leon; Michael J Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; Mathew Williams; Todd Dewey; Samir Kapadia; Vasilis Babaliaros; Vinod H Thourani; Paul Corso; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Jodi J Akin; William N Anderson; Duolao Wang; Stuart J Pocock
Journal:  N Engl J Med       Date:  2011-06-05       Impact factor: 91.245

3.  Preoperative assessment of aortic annulus dimensions: comparison of noninvasive and intraoperative measurement.

Authors:  Alexey Dashkevich; Philipp Blanke; Matthias Siepe; Gregor Pache; Mathias Langer; Christian Schlensak; Friedhelm Beyersdorf
Journal:  Ann Thorac Surg       Date:  2011-03       Impact factor: 4.330

Review 4.  Moderate and severe preoperative chronic kidney disease worsen clinical outcomes after transcatheter aortic valve implantation: meta-analysis of 4992 patients.

Authors:  Giuseppe Gargiulo; Davide Capodanno; Anna Sannino; Cinzia Perrino; Piera Capranzano; Eugenio Stabile; Bruno Trimarco; Corrado Tamburino; Giovanni Esposito
Journal:  Circ Cardiovasc Interv       Date:  2015-02       Impact factor: 6.546

5.  Comparison of aortic annulus size by transesophageal echocardiography and computed tomography angiography with direct surgical measurement.

Authors:  Hanghang Wang; Jennifer M Hanna; Asvin Ganapathi; Jeffrey E Keenan; Lynne M Hurwitz; John P Vavalle; Todd L Kiefer; Andrew Wang; J Kevin Harrison; G Chad Hughes
Journal:  Am J Cardiol       Date:  2015-03-12       Impact factor: 2.778

6.  Two-year outcomes after transcatheter or surgical aortic-valve replacement.

Authors:  Susheel K Kodali; Mathew R Williams; Craig R Smith; Lars G Svensson; John G Webb; Raj R Makkar; Gregory P Fontana; Todd M Dewey; Vinod H Thourani; Augusto D Pichard; Michael Fischbein; Wilson Y Szeto; Scott Lim; Kevin L Greason; Paul S Teirstein; S Chris Malaisrie; Pamela S Douglas; Rebecca T Hahn; Brian Whisenant; Alan Zajarias; Duolao Wang; Jodi J Akin; William N Anderson; Martin B Leon
Journal:  N Engl J Med       Date:  2012-03-26       Impact factor: 91.245

7.  MSCT guided sizing of the Edwards Sapien XT TAVI device: impact of different degrees of oversizing on clinical outcome.

Authors:  A W Leber; W Eichinger; J Rieber; M Lieber; S Schleger; U Ebersberger; M Deichstetter; J Vogel; T Helmberger; D Antoni; G Riess; E Hoffmann; A M Kasel
Journal:  Int J Cardiol       Date:  2013-04-12       Impact factor: 4.164

8.  Aortic annulus and ascending aorta: comparison of preoperative and periooperative measurement in patients with aortic stenosis.

Authors:  Michal Smíd; Jirí Ferda; Jan Baxa; Jakub Cech; Tomás Hájek; Boris Kreuzberg; Richard Rokyta
Journal:  Eur J Radiol       Date:  2009-02-23       Impact factor: 3.528

9.  Diffuse myocardial fibrosis in severe aortic stenosis: an equilibrium contrast cardiovascular magnetic resonance study.

Authors:  Andrew S Flett; Daniel M Sado; Giovanni Quarta; Mariana Mirabel; Denis Pellerin; Anna S Herrey; Derek J Hausenloy; Cono Ariti; John Yap; Shyam Kolvekar; Andrew M Taylor; James C Moon
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2012-05-25       Impact factor: 6.875

10.  Cardiovascular magnetic resonance for the assessment of patients undergoing transcatheter aortic valve implantation: a pilot study.

Authors:  Alessio La Manna; Alessandra Sanfilippo; Davide Capodanno; Antonella Salemi; Gesualdo Polizzi; Wanda Deste; Glauco Cincotta; Alessandra Cadoni; Anna Marchese; Michele Figuera; Gian P Ussia; Rosetta Pittalà; Carmelo Privitera; Corrado Tamburino
Journal:  J Cardiovasc Magn Reson       Date:  2011-12-27       Impact factor: 5.364

View more
  7 in total

1.  Multi-parametric approach to predict prosthetic valve size using CMR and clinical data: insights from SAVR.

Authors:  Federico E Mordini; Conor F Hynes; Richard L Amdur; Jeffrey Panting; Dominic A Emerson; Jason Morrissette; Erin Goheen-Thomas; Michael D Greenberg; Gregory D Trachiotis
Journal:  Int J Cardiovasc Imaging       Date:  2021-03-10       Impact factor: 2.357

Review 2.  The contemporary role of echocardiography in the assessment and management of aortic stenosis.

Authors:  Takeshi Kitai; Rayji S Tsutsui
Journal:  J Med Ultrason (2001)       Date:  2019-12-02       Impact factor: 1.314

3.  Accuracy of cardiac magnetic resonance generated 3D models of the aortic annulus compared to cardiovascular computed tomography generated 3D models.

Authors:  Marco Gatti; Aurelio Cosentino; Erik Cura Stura; Laura Bergamasco; Domenica Garabello; Giovanni Pennisi; Mattia Puppo; Stefano Salizzoni; Simona Veglia; Ottavio Davini; Mauro Rinaldi; Paolo Fonio; Riccardo Faletti
Journal:  Int J Cardiovasc Imaging       Date:  2020-05-30       Impact factor: 2.357

Review 4.  Multimodality Imaging for Left Ventricular Hypertrophy Severity Grading: A Methodological Review.

Authors:  Maaike Alkema; Ernest Spitzer; Osama I I Soliman; Christian Loewe
Journal:  J Cardiovasc Ultrasound       Date:  2016-12-28

Review 5.  3D transoesophageal echocardiography in the TAVI sizing arena: should we do it and how do we do it?

Authors:  Caroline Bleakley; Mehdi Eskandari; Mark Monaghan
Journal:  Echo Res Pract       Date:  2017-03

6.  Cardiovascular imaging 2016 in the International Journal of Cardiovascular Imaging.

Authors:  Johan H C Reiber; Johan De Sutter; Paul Schoenhagen; Arthur E Stillman; Nico R L Vande Veire
Journal:  Int J Cardiovasc Imaging       Date:  2017-06       Impact factor: 2.357

Review 7.  The Pivotal Role of Imaging in TAVR Procedures.

Authors:  Caroline Bleakley; Mark J Monaghan
Journal:  Curr Cardiol Rep       Date:  2018-02-12       Impact factor: 2.931

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.