BACKGROUND: Preoperative assessment of aortic annulus diameter is crucial for valve sizing in patients scheduled for transcatheter aortic valve replacement. Computed tomographic (CT) measurements of the aortic annulus are not standardized and may yield different results depending on view due to its elliptic shape. The purpose of this study was to compare the measurement of the aortic annulus during surgery in patients undergoing conventional aortic valve replacement with noninvasive methods.
METHODS: In 33 patients with aortic valve stenosis (18 males, mean age 77.2 ± 7.9), aortic annulus diameter was measured with cardiac CT and TEE (transesophageal echocardiography) prior to open aortic valve replacement. In CT, aortic annulus diameter was assessed as the calculated average diameter of luminal area at the level of basal attachments of the leaflets by means of planimetry. Operative measurements were performed with a Hegar dilator. A Pearson analysis was applied to test for degree of correlation.
RESULTS: Calculated average diameter by CT correlated significantly with intraoperative measurements (r = 0.923, p < 0.001) and with the size of implanted valve (r = 0.867, p < 0.001), while correlation of TEE and intraoperative measurements was weak (r = 0.523, p = 0.002). The TEE tends to underestimate the dimensions of aortic annulus.
CONCLUSIONS: The CT-measured aortic annulus diameter, assessed as the calculated average diameter of planimetric annulus area, seems to provide adequate dimensions similar to operative measurements with a Hegar dilator. This approach may minimize the dependency of single-view CT measurement on the elliptic shape of the aortic annulus and appears to be a feasible alternative for aortic annulus assessment in terms of candidates' selection for transcatheter aortic valve replacement.
Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21352983     DOI: 10.1016/j.athoracsur.2010.09.038

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  13 in total

1.  Cyclic changes in area- and perimeter-derived effective dimensions of the aortic annulus measured with multislice computed tomography and comparison with metric intraoperative sizing.

Authors:  Won-Keun Kim; Alexander Meyer; Helge Möllmann; Andreas Rolf; Susanne Möllmann; Johannes Blumenstein; Arnaud Van Linden; Christian W Hamm; Thomas Walther; Jörg Kempfert
Journal:  Clin Res Cardiol       Date:  2016-02-18       Impact factor: 5.460

2.  Sizing the aortic annulus.

Authors:  Alfredo G Cerillo; Massimiliano Mariani; Sergio Berti; Mattia Glauber
Journal:  Ann Cardiothorac Surg       Date:  2012-07

3.  Multi-parametric approach to predict prosthetic valve size using CMR and clinical data: insights from SAVR.

Authors:  Federico E Mordini; Conor F Hynes; Richard L Amdur; Jeffrey Panting; Dominic A Emerson; Jason Morrissette; Erin Goheen-Thomas; Michael D Greenberg; Gregory D Trachiotis
Journal:  Int J Cardiovasc Imaging       Date:  2021-03-10       Impact factor: 2.357

4.  Cardiovascular magnetic resonance as a reliable alternative to cardiovascular computed tomography and transesophageal echocardiography for aortic annulus valve sizing.

Authors:  Riccardo Faletti; Marco Gatti; Stefano Salizzoni; Laura Bergamasco; Rodolfo Bonamini; Domenica Garabello; Walter Grosso Marra; Michele La Torre; Mara Morello; Simona Veglia; Paolo Fonio; Mauro Rinaldi
Journal:  Int J Cardiovasc Imaging       Date:  2016-04-27       Impact factor: 2.357

Review 5.  Multidetector Computed Tomography (MDCT) Angiography in the Pre-Procedural Assessment of Patients Undergoing Transcatheter Aortic Valve Replacement.

Authors:  Cihan Duran; Irfan Masood; Alper Duran; Luba Frank; Arsalan Saleem; Raja Muthupillai; Benjamin Y C Cheong
Journal:  Eurasian J Med       Date:  2020-02

6.  Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation.

Authors:  Mohammad A Sherif; Hüseyin Ince; Octavian Maniuc; Therese Reiter; Wolfram Voelker; Georg Ertl; Alper Öner
Journal:  BMC Cardiovasc Disord       Date:  2015-12-29       Impact factor: 2.298

7.  Preoperative aortic annulus size assessment by transthoracic echocardiography compared to the size of surgically implanted aortic prostheses.

Authors:  I J Ingimarsdóttir; L Hellgren Johansson; F A Flachskampf
Journal:  Echo Res Pract       Date:  2019-06-01

8.  Transesophageal echocardiography measurements of aortic annulus diameter using biplane mode in patients undergoing transcatheter aortic valve implantation.

Authors:  Kambiz Shahgaldi; Cristina da Silva; Magnus Bäck; Andreas Rück; Aristomenis Manouras; Anders Sahlén
Journal:  Cardiovasc Ultrasound       Date:  2013-01-30       Impact factor: 2.062

9.  Comparison of aortic annulus diameter measurement between multi-detector computed tomography and echocardiography: a meta-analysis.

Authors:  Ruifang Zhang; Yi Song; Yuanyuan Zhou; Lulu Sun
Journal:  PLoS One       Date:  2013-03-14       Impact factor: 3.240

10.  Feasibility of a new method using two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation; a case-control study.

Authors:  Mohammad A Sherif; Joerg Herold; Wolfram Voelker; Octavian Maniuc; Georg Ertl; Christian Praast; Ruediger Christian Braun-Dullaeus
Journal:  BMC Cardiovasc Disord       Date:  2015-07-28       Impact factor: 2.298

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.