Literature DB >> 23587400

MSCT guided sizing of the Edwards Sapien XT TAVI device: impact of different degrees of oversizing on clinical outcome.

A W Leber1, W Eichinger, J Rieber, M Lieber, S Schleger, U Ebersberger, M Deichstetter, J Vogel, T Helmberger, D Antoni, G Riess, E Hoffmann, A M Kasel.   

Abstract

AIMS: Prospective data on the usage of 3-dimensional imaging based annulus sizing on the outcome of TAVI is not available yet and there is general uncertainty about the optimal degree of oversizing. In the current study we therefore assessed a 3-D MSCT guided over-sizing approach and evaluated the clinical outcome of different degrees of oversizing.
METHODS: TAVI-size-selection was done using systolic MSCT-annulus cross-sectional-area (CSA) measurements in 107 patients with severe aortic stenosis with the goal to oversize the 3rd generation balloon expandable Edwards Sapien XT (ESTV) device in relation to the native aortic annulus CSA.
RESULTS: Among different degrees of oversizing there were no differences in the occurrence of stroke, myocardial infarction and death. No aortic injuries were observed. The overall rate of >mild postprocedural aortic regurgitation (PAR) was 7.6%. Increasing oversizing ratios are associated with lower rates of >mild PAR (r = -0.236, p<0.02) with the lowest rate of >mild PAR in patients with area based oversizing ratios >25% and the highest rate in patients with oversizing ratios <15% (0% vs. 15.8%, p<0.02). The rate of postprocedural permanent pacemakers tended to be lower in patients with <15% oversizing compared to those with >25% oversizing (5.3 vs. 16.7%, p<0.23).
CONCLUSIONS: MSCT guided ESTV-device sizing is safe and is associated with significantly lower than previously reported rates for PAR. A device/annulus oversizing ratio of 15-25% based on area and 7-12% based on mean diameter appears to provide the best risk-benefit ratio in terms of PAR reduction and conduction disorders.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  AR; Aortic stenosis; CSA; ESTV; Edwards Sapien Transcatheter Heart Valve; MSCT; PAR; PM; TAVI; TEE; Transcatheter valve therapy; aortic regurgitation; cross sectional area; multi slice CT; pacemaker; postprocedural aortic regurgitation; transcatheter aortic valve implantation; transesophageal echocardiography

Mesh:

Year:  2013        PMID: 23587400     DOI: 10.1016/j.ijcard.2013.03.030

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  11 in total

1.  Cardiovascular magnetic resonance as a reliable alternative to cardiovascular computed tomography and transesophageal echocardiography for aortic annulus valve sizing.

Authors:  Riccardo Faletti; Marco Gatti; Stefano Salizzoni; Laura Bergamasco; Rodolfo Bonamini; Domenica Garabello; Walter Grosso Marra; Michele La Torre; Mara Morello; Simona Veglia; Paolo Fonio; Mauro Rinaldi
Journal:  Int J Cardiovasc Imaging       Date:  2016-04-27       Impact factor: 2.357

Review 2.  On the Mechanics of Transcatheter Aortic Valve Replacement.

Authors:  Lakshmi P Dasi; Hoda Hatoum; Arash Kheradvar; Ramin Zareian; S Hamed Alavi; Wei Sun; Caitlin Martin; Thuy Pham; Qian Wang; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-11-21       Impact factor: 3.934

Review 3.  Permanent pacemaker insertion in patients with conduction abnormalities post transcatheter aortic valve replacement: a review and proposed guidelines.

Authors:  Tamunoinemi Bob-Manuel; Amit Nanda; Samuel Latham; Issa Pour-Ghaz; William Paul Skelton; Rami N Khouzam
Journal:  Ann Transl Med       Date:  2018-01

4.  Applicability of next generation balloon-expandable transcatheter heart valves in aortic annuli exceeding formally approved dimensions.

Authors:  Andreas Schaefer; Matthias Linder; Hendrik Treede; Florian Deuschl; Niklas Schofer; Moritz Seiffert; Yvonne Schneeberger; Stefan Blankenberg; Hermann Reichenspurner; Ulrich Schaefer; Lenard Conradi
Journal:  Clin Res Cardiol       Date:  2015-12-17       Impact factor: 5.460

5.  Impact of Transcatheter Aortic Valve Size on Leaflet Stresses: Implications for Durability and Optimal Grey Zone Sizing.

Authors:  Yue Xuan; Danny Dvir; Andrew D Wisneski; Zhongjie Wang; Jian Ye; Julius M Guccione; Liang Ge; Elaine E Tseng
Journal:  AsiaIntervention       Date:  2020-12

6.  Imaging in Transcatheter Aortic Valve Replacement (TAVR): role of the radiologist.

Authors:  Diana E Litmanovich; Eduard Ghersin; David A Burke; Jeffrey Popma; Maryam Shahrzad; Alexander A Bankier
Journal:  Insights Imaging       Date:  2014-01-21

7.  Prognostic value of the ratio between prosthesis area and indexed annulus area measured by MultiSlice-CT for transcatheter aortic valve implantation procedures.

Authors:  Nicolas Debry; Arnaud Sudre; Ibrahim Elquodeimat; Cédric Delhaye; Guillaume Schurtz; Antoine Bical; Mohamad Koussa; Khalil Fattouch; Thomas Modine
Journal:  J Geriatr Cardiol       Date:  2016-09       Impact factor: 3.327

Review 8.  Rate and Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation: Current Status.

Authors:  Eleonora Russo; Domenico R Potenza; Michela Casella; Raimondo Massaro; Giulio Russo; Maurizio Braccio; Antonio Dello Russo; Mauro Cassese
Journal:  Curr Cardiol Rev       Date:  2019

9.  Transcatheter aortic valve implantation in patients with bicuspid aortic valve stenosis utilizing the next-generation fully retrievable and repositionable valve system: mid-term results from a prospective multicentre registry.

Authors:  Janusz Kochman; Karol Zbroński; Łukasz Kołtowski; Radosław Parma; Andrzej Ochała; Zenon Huczek; Bartosz Rymuza; Radosław Wilimski; Maciej Dąbrowski; Adam Witkowski; Piotr Scisło; Marek Grygier; Maciej Lesiak; Grzegorz Opolski
Journal:  Clin Res Cardiol       Date:  2019-09-02       Impact factor: 5.460

10.  Comparison of SAPIEN 3 and SAPIEN XT transcatheter heart valve stent-frame expansion: evaluation using multi-slice computed tomography.

Authors:  Yoshio Kazuno; Yoshio Maeno; Hiroyuki Kawamori; Nobuyuki Takahashi; Yigal Abramowitz; Hariri Babak; Mohammad Kashif; Tarun Chakravarty; Mamoo Nakamura; Wen Cheng; John Friedman; Daniel Berman; Raj R Makkar; Hasan Jilaihawi
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2016-03-21       Impact factor: 6.875

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.