| Literature DB >> 27087974 |
Majella Russo1, Rebecca Owen2, Anne Bernard3, Vaughan Moutrie1, Matthew Foote4.
Abstract
INTRODUCTION: Accurate localisation is an essential component for the delivery of intracranial stereotactic treatment. For fractionated stereotactic radiotherapy, we compared the daily localisation accuracy of a standard thermoplastic mask with a new maxillary fixation device (MFD).Entities:
Keywords: Intracranial; radiotherapy; stereotactic
Mesh:
Year: 2015 PMID: 27087974 PMCID: PMC4775825 DOI: 10.1002/jmrs.142
Source DB: PubMed Journal: J Med Radiat Sci ISSN: 2051-3895
Figure 1(A) Components of the Elekta Fraxion stabilisation system. PCU, headframe and frontpiece with mouthpiece and inflated vacuum headrest (image courtesy of Princess Alexandra Hospital Radiation Oncology Department). (B) Elekta Fraxion system in place for patient set up (image courtesy of Elekta, Elekta catalogue).
Proportion of CBCT images outside imaging action thresholds for the standard mask and new MFD conditions
| Imaging action threshold | Condition | Number of images | |||||
|---|---|---|---|---|---|---|---|
| Translation | Rotation | ||||||
| Left/right | Superior/inferior | Anterior/posterior | Left/right | Superior/inferior | Anterior/posterior | ||
| ≥1 mm/1° | Standard | 128/326 | 180/326 | 171/326 | 121/326 | 138/326 | 105/326 |
| (%) | 39.26 | 55.21 | 52.45 | 37.12 | 42.33 | 32.21 | |
| New | 201/356 | 167/356 | 143/356 | 50/356 | 65/356 | 67/356 | |
| (%) | 56.46 | 46.91 | 40.17 | 14.04 | 18.26 | 18.82 | |
| ≥2 mm/2° | Standard | 67/326 | 71/326 | 64/326 | 22/326 | 33/326 | 15/326 |
| (%) | 20.55 | 21.78 | 19.63 | 6.75 | 10.12 | 4.6 | |
| New | 61/356 | 49/356 | 71/356 | 5/356 | 0/356 | 0/356 | |
| (%) | 17.13 | 13.76 | 19.94 | 1.4 | 0 | 0 | |
MFD, maxillary fixation device; CBCT, cone‐beam computed tomography.
Errors for individuals in standard mask versus new MFD conditions
| Mean systematic error ( | Mean random error ( | |||||
|---|---|---|---|---|---|---|
| Direction | Standard mask | MFD |
| Standard mask | MFD |
|
| Trans (L/R) | 0.5 | −0.3 | 0.43 | 0.3 | 0.2 | 0.52 |
| Trans (S/I) | 0.5 | 0.5 | 0.91 | 0.3 | 0.3 | 0.55 |
| Trans (A/P) | −0.8 | 0.6 | 0.02 | 0.2 | 0.2 | 0.16 |
Indicates statistical significance.
MFD, maxillary fixation device; L/R, left/right; S/I, superior/inferior; A/P, anterior/posterior; trans, translational planes; rot, rotation.
Figure 2Individual mean set up errors for rotation in the standard mask and new MFD conditions. rot, rotation; stand, standard; X rotation, pitch; Y rotation, roll; Z rotation, yaw.
Summarised data of errors and margin calculations in the standard mask and new MFD devices
| Condition | Direction | Population set up errors | Van Herk's (2.5 | Stroom's (2 | |
|---|---|---|---|---|---|
| Systematic ( | Random ( | ||||
| Standard | Trans L/R (mm) | 0.8 | 0.3 | 2.2 | 1.8 |
| Trans S/I (mm) | 0.2 | 0.3 | 0.7 | 0.6 | |
| Trans A/P (mm) | 0.2 | 0.2 | 0.6 | 0.5 | |
| Rot pitch (degrees) | 1.02 | 0.21 | |||
| Rot roll (degrees) | 0.47 | 0.30 | |||
| Rot yaw (degrees) | 0.39 | 0.18 | |||
| New | Trans L/R (mm) | 0.2 | 0.2 | 0.6 | 0.5 |
| Trans S/I (mm) | 0.1 | 0.3 | 0.5 | 0.4 | |
| Trans A/P (mm) | 0.2 | 0.2 | 0.6 | 0.5 | |
| Rot pitch (degrees) | 0.21 | 0.16 | |||
| Rot roll (degrees) | 0.19 | 0.07 | |||
| Rot yaw (degrees) | 0.21 | 0.09 | |||
MFD, maxillary fixation device; L/R, left/right; S/I, superior/inferior; A/P, anterior/posterior; trans, translational planes; rot, rotation.