Literature DB >> 19131299

Minimally redundant 2-D array designs for 3-D medical ultrasound imaging.

Mustafa Karaman1, Ira O Wygant, Omer Oralkan, Butrus T Khuri-Yakub.   

Abstract

In real-time ultrasonic 3-D imaging, in addition to difficulties in fabricating and interconnecting 2-D transducer arrays with hundreds of elements, there are also challenges in acquiring and processing data from a large number of ultrasound channels. The coarray (spatial convolution of the transmit and receive arrays) can be used to find efficient array designs that capture all of the spatial frequency content (a transmit-receive element combination corresponds to a spatial frequency) with a reduced number of active channels and firing events. Eliminating the redundancies in the transmit-receive element combinations and firing events reduces the overall system complexity and improves the frame rate. Here we explore four reduced redundancy 2-D array configurations for miniature 3-D ultrasonic imaging systems. Our approach is based on 1) coarray design with reduced redundancy using different subsets of linear arrays constituting the 2-D transducer array, and 2) 3-D scanning using fan-beams (narrow in one dimension and broad in the other dimension) generated by the transmit linear arrays. We form the overall array response through coherent summation of the individual responses of each transmit-receive array pairs. We present theoretical and simulated point spread functions of the array configurations along with quantitative comparison in terms of the front-end complexity and image quality.

Mesh:

Year:  2009        PMID: 19131299     DOI: 10.1109/TMI.2008.2010936

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  16 in total

1.  Beamforming of sound from two-dimensional arrays using spatial matched filters.

Authors:  Jesse T Yen
Journal:  J Acoust Soc Am       Date:  2013-11       Impact factor: 1.840

2.  Design Optimization for a 2-D Sparse Transducer Array for 3-D Ultrasound Imaging.

Authors:  Jung Woo Choe; Omer Oralkan; Pierre T Khuri-Yakub
Journal:  Proc IEEE Ultrason Symp       Date:  2010-10-11

3.  Improving beamforming performance by phased synthetic aperture imaging in medical ultrasound.

Authors:  Masume Sadeghi; Ali Mahloojifar
Journal:  J Med Ultrason (2001)       Date:  2016-10-28       Impact factor: 1.314

4.  Volumetric imaging using single chip integrated CMUT-on-CMOS IVUS array.

Authors:  Coskun Tekes; Jaime Zahorian; Gokce Gurun; Sarp Satir; Toby Xu; Michael Hochman; F Levent Degertekin
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

5.  Optimizing circular ring arrays for forward-looking IVUS imaging.

Authors:  Coskun Tekes; Mustafa Karaman; F Levent Degertekin
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-12       Impact factor: 2.725

6.  A novel adaptive apodization to improve the resolution of phased subarray imaging in medical ultrasound.

Authors:  Masume Sadeghi; Ali Mahloojifar
Journal:  J Med Ultrason (2001)       Date:  2019-09-20       Impact factor: 1.314

7.  Application of X-Y separable 2-D array beamforming for increased frame rate and energy efficiency in handheld devices.

Authors:  Kevin Owen; Michael Fuller; John Hossack
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-07       Impact factor: 2.725

8.  Gap-filling method for suppressing grating lobes in ultrasound imaging: Experimental study with deep-learning approach.

Authors:  Viksit Kumar; Po-Yang Lee; Bae-Hyung Kim; Mostafa Fatemi; Azra Alizad
Journal:  IEEE Access       Date:  2020-04-21       Impact factor: 3.367

9.  Gap-filling method for suppressing grating lobes in ultrasound imaging: Theory and simulation results.

Authors:  Bae-Hyung Kim; Viksit Kumar; Azra Alizad; Mostafa Fatemi
Journal:  J Acoust Soc Am       Date:  2019-03       Impact factor: 1.840

10.  Singulation for imaging ring arrays of capacitive micromachined ultrasonic transducers.

Authors:  Chienliu Chang; Azadeh Moini; Amin Nikoozadeh; Ali Fatih Sarioglu; Nikhil Apte; Xuefeng Zhuang; Butrus T Khuri-Yakub
Journal:  J Micromech Microeng       Date:  2014-09-17       Impact factor: 1.881

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.