Literature DB >> 18212212

Gas bubble motion artifact in MDCT.

Franklin Liu1, Carlos Cuevas, Albert A Moss, Orpheus Kolokythas, Theodore J Dubinsky, Paul E Kinahan.   

Abstract

OBJECTIVE: The purpose of our study was to characterize the imaging features of an MDCT artifact caused by gas bubble motion.
MATERIALS AND METHODS: For the period 2002-2006, the CT images of 10 patients that revealed a curvilinear artifact thought to be due to a gas bubble moving during CT acquisition were retrospectively identified and reviewed by an attending body radiologist. The clinical images were acquired on MDCT scanners. A phantom containing water and moving air bubbles (gas injection rates of 0.1 and 0.5 mL/s) was designed, built, and scanned using a 16-MDCT scanner. Computer simulation was used to test our hypothesis that these observed artifacts originated from moving gas bubbles.
RESULTS: Semicircular tubular CT artifacts with attenuation close to that of air were observed in all 10 clinical cases. The acquired MDCT images from the phantom and the computer simulations showed tubular air-attenuation semicircular artifacts that closely matched the imaging findings on the 10 clinical cases. Increased rates of bubble injection multiplied the artifact. Based on the computer simulation, the precise appearance of the artifact depends on the bubble location and velocity relative to the rotation of the CT scanner.
CONCLUSION: Gas bubble motion during CT generates a semicircular air-attenuation artifact that has not been previously described to our knowledge. The artifact is typically found in bowel and other liquid-containing structures in which a bubble of gas floats up through a liquid medium during CT.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18212212     DOI: 10.2214/AJR.07.2702

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  Reduction of peristalsis-related gastrointestinal streak artifacts with dual-energy CT: a patient and phantom study.

Authors:  Sebastian Winklhofer; Jack W Lambert; Zhen Jane Wang; Yuxin Sun; Robert G Gould; Ronald J Zagoria; Benjamin M Yeh
Journal:  Abdom Radiol (NY)       Date:  2016-08

2.  Motion Induced Artifact Mimicking Cervical Dens Fracture on the CT Scan: A Case Report.

Authors:  Yoshihisa Sugimoto; Yasuo Ito; Yasuyuki Shiozaki; Tetsuya Shimokawa; Tetsuro Mazaki
Journal:  Asian Spine J       Date:  2012-08-21

3.  Reduction of Peristalsis-Related Streak Artifacts on the Liver with Dual-Layer Spectral CT.

Authors:  Sergio Grosu; Zhen J Wang; Markus M Obmann; Mark D Sugi; Yuxin Sun; Benjamin M Yeh
Journal:  Diagnostics (Basel)       Date:  2022-03-23
  3 in total