Sergio Grosu1,2, Zhen J Wang1, Markus M Obmann1,3, Mark D Sugi1, Yuxin Sun1, Benjamin M Yeh1.
Abstract
BACKGROUND: Peristalsis-related streak artifacts on the liver compromise image quality and diagnostic accuracy.Entities:
Keywords: DECT; X-ray computed; abdomen; artifacts; humans; liver; peristalsis; tomography
Year: 2022 PMID: 35453830 PMCID: PMC9028529 DOI: 10.3390/diagnostics12040782
Source DB: PubMed Journal: Diagnostics (Basel) ISSN: 2075-4418
Figure 1Flow diagram of the study population. CT (Computed tomography).
Figure 2Axial contrast-enhanced CT scan of a 65-year-old man. Streak artifact (indicated by arrows) on the left liver lobe originating from peristaltic motion of the stomach visible in the (A) conventional 120 kVp image and (B) virtual non-contrast (VNC) image reconstruction. The streak artifact is markedly reduced in the (C) iodine image reconstruction, resulting in a better visibility of the underlying liver tissue.
Figure 3Axial contrast-enhanced CT scan of a 67-year-old man. Hyperdensity (indicated by arrows) on the left liver lobe in the (A,B) conventional 120 kVp image using an (A) abdomen window and (B) liver window, which might be interpreted as a hyperenhancing liver lesion. The (C) virtual non-contrast (VNC) image reconstruction and (D) iodine image reconstruction reveal that it is not a hyperenhancing liver lesion, but a streak artifact originating from the stomach antrum.
Figure 4Axial contrast-enhanced CT scan of an 86-year-old man. Hyperdensity (indicated by arrows) on the left liver lobe in the (A) conventional 120 kVp image, which might be interpreted as a peristalsis-related streak artifact originating from the stomach. The (B) virtual non-contrast (VNC) image reconstruction and (C) iodine image reconstruction reveal that it is not a streak artifact, but a hyperenhancing liver lesion.
Qualitative score of peristalsis-related streak artifact severity on the liver of Reader A and B in conventional 120 kVp images, 40 keV monoenergetic images, 200 keV monoenergetic images, virtual non-contrast (VNC) images, and iodine images.
| Reader A | |||||
|---|---|---|---|---|---|
| Image Reconstructions | Score | ||||
| 1 | 2 | 3 | 4 | 5 | |
| 120 kVp | 0/51 (0%) | 22/51 (43%) | 18/51 (35%) | 9/51 (18%) | 2/51 (4%) |
| 40 keV | 3/51 (6%) | 19/51 (37%) | 17/51 (33%) | 5/51 (10%) | 7/51 (14%) |
| 200 keV | 0/51 (0%) | 23/51 (45%) | 15/51 (29%) | 11/51 (22%) | 2/51 (4%) |
| VNC | 1/51 (2%) | 22/51 (43%) | 14/51 (27%) | 12/51 (24%) | 2/51 (4%) |
| iodine | 33/51 (65%) | 14/51 (27%) | 4/51 (8%) | 0/51 (0%) | 0/51 (0%) |
|
| |||||
|
|
| ||||
|
|
|
|
|
| |
| 120 kVp | 0/51 (0%) | 9/51 (18%) | 19/51 (37%) | 11/51 (22%) | 12/51 (24%) |
| 40 keV | 10/51 (20%) | 11/51 (22%) | 16/51 (31%) | 4/51 (8%) | 10/51 (20%) |
| 200 keV | 1/51 (2%) | 4/51 (8%) | 16/51 (31%) | 12/51 (24%) | 18/51 (35%) |
| VNC | 1/51 (2%) | 5/51 (10%) | 16/51 (31%) | 12/51 (24%) | 17/51 (33%) |
| iodine | 42/51 (82%) | 4/51 (8%) | 2/51 (4%) | 3/51 (6%) | 0/51 (0%) |
Score 1 = Absence of streak artifact on the liver; Score 2 = Visible streak artifact with no effect on diagnosis on the liver; Score 3 = Moderate streak artifact that may decrease confidence in diagnosing a 0.5 to 0.9 cm liver lesion; Score 4 = Distinct streak artifact that prevents the diagnosis of a 0.5 to 0.9 cm liver lesion and may decrease confidence in diagnosing a ≥1.0 cm liver lesion; Score 5 = Severe streak artifact that prevents the diagnosis of a ≥1.0 cm liver lesion.
Figure 5Depth of extension of peristalsis-related streak artifacts into the liver parenchyma measured on axial conventional 120 kVp images, 40 keV monoenergetic images, 200 keV monoenergetic images, virtual non-contrast (VNC) images, and iodine images.
Quantitative measurements of peristalsis-related streak artifacts on the liver on conventional 120 kVp images, 40 keV monoenergetic images, 200 keV monoenergetic images, virtual non-contrast (VNC) images, and iodine images.
| Image Reconstructions | Quantitative Artifact Measurements | ||||
|---|---|---|---|---|---|
| Mean ROImax | Mean ROImin | Mean ROIref | Mean ROImax Compared with Mean ROIref | Mean ROImin Compared with Mean ROIref | |
| 120 kVp | 129 HU | 80 HU | 101 HU | ||
| 40 keV | 232 HU | 168 HU | 201 HU | ||
| 200 keV | 91 HU | 48 HU | 67 HU | ||
| VNC | 87 HU | 45 HU | 61 HU | ||
| iodine | 1.72 mg/mL | 1.44 mg/mL | 1.68 mg/mL | ||
ROImax (regions of interest measurement in the most visibly bright area of the streak artifact). ROImin (regions of interest measurement in the most visibly dark area of the streak artifact). ROIref (regions of interest measurement in the neighboring liver parenchyma not affected by artifacts).