Literature DB >> 26956876

Comparison of biventricular ejection fractions using cadmium-zinc-telluride SPECT and planar equilibrium radionuclide angiography.

Yi-Chieh Chen1, Chi-Lun Ko2, Rouh-Fang Yen1, Mei-Fang Lo1, Yih-Hwen Huang1,3, Pei-Ying Hsu2, Yen-Wen Wu4,5,6,7, Mei-Fang Cheng8,9.   

Abstract

BACKGROUND: We compared biventricular ejection fractions (EFs) from gated blood-pool single-photon emission computed tomography (SPECT) using a cadmium-zinc-telluride camera (CZT-SPECT) with planar equilibrium radionuclide angiography (ERNA) using a NaI gamma camera (NaI-planar). We also evaluated whether imaging time can be reduced without compromising image quality using the CZT camera.
METHODS: Forty-eight patients underwent NaI-planar and CZT-SPECT on the same day. CZT-SPECT datasets were re-projected at an LAO orientation similar to ERNA acquisition, forming CZT-repro planar datasets. The resulting biventricular volumetric measurements and EFs were compared.
RESULTS: LVEF calculated from CZT-SPECT and CZT-repro correlated better with NaI-planar (r = 0.93 and 0.99, respectively) than RVEF (r = 0.76 and 0.82, respectively). Excellent intra-class correlation and low bias in intra-observer comparisons were observed for the biventricular EFs derived from three datasets. A wider limit of agreement in CZT-SPECT-derived LVEFs, lower correlation and significant bias for NaI-planar, and CZT-repro-derived RVEFs was found in the inter-observer analyses. Nonetheless, the imaging time can be reduced to 4 minutes without increasing variability in EFs using the CZT camera (P = NS).
CONCLUSIONS: LVEFs calculated from CZT-SPECT and CZT-repro correlated well with NaI-planar. CZT camera may reduce imaging time while preserving image quality in the assessment of biventricular EFs.

Entities:  

Keywords:  Cadmium-zinc-telluride camera; gated blood-pool SPECT; planar equilibrium radionuclide angiography; ventricular ejection fractions

Mesh:

Substances:

Year:  2016        PMID: 26956876     DOI: 10.1007/s12350-015-0367-1

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  26 in total

1.  Planar imaging versus gated blood-pool SPECT for the assessment of ventricular performance: a multicenter study.

Authors:  M W Groch; E G DePuey; A C Belzberg; W D Erwin; M Kamran; C A Barnett; R C Hendel; S M Spies; A Ali; R C Marshall
Journal:  J Nucl Med       Date:  2001-12       Impact factor: 10.057

2.  Equilibrium radionuclide angiocardiography.

Authors:  James R Corbett; Olakunle O Akinboboye; Stephen L Bacharach; Jeffrey S Borer; Elias H Botvinick; E Gordon DePuey; Edward P Ficaro; Christopher L Hansen; Milena J Henzlova; Serge Van Kriekinge
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

3.  Influence of CT-based attenuation correction in assessment of left and right ventricular functions with count-based gated blood-pool SPECT.

Authors:  Louis Sibille; Fayçal Ben Bouallegue; Aurélie Bourdon; Denis Mariano-Goulart
Journal:  J Nucl Cardiol       Date:  2011-06-07       Impact factor: 5.952

4.  Interstudy repeatability of left and right ventricular volume estimations by serial-gated tomographic radionuclide angiographies using a cadmium-zinc-telluride detector gamma camera.

Authors:  Maria M Jensen; Christine Haase; Bo Zerahn
Journal:  Clin Physiol Funct Imaging       Date:  2014-06-30       Impact factor: 2.273

5.  Comparative values of gated blood-pool SPECT and CMR for ejection fraction and volume estimation.

Authors:  Louis Sibille; Fayçal Ben Bouallegue; Aurélie Bourdon; Antoine Micheau; Hélène Vernhet-Kovacsik; Denis Mariano-Goulart
Journal:  Nucl Med Commun       Date:  2011-02       Impact factor: 1.690

6.  Low-dose thallium-201 protocol with a cadmium-zinc-telluride cardiac camera.

Authors:  Bernard Songy; Mohamed Guernou; David Lussato; Mathieu Queneau; Ricardo Geronazzo
Journal:  Nucl Med Commun       Date:  2012-05       Impact factor: 1.690

7.  Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT.

Authors:  Seong-Jang Kim; In-Ju Kim; Yun-Seong Kim; Yong-Ki Kim
Journal:  Int J Cardiovasc Imaging       Date:  2005 Apr-Jun       Impact factor: 2.357

8.  Assessment of an intermediate reprojection technique transitioning from planar to SPECT radionuclide ventriculography.

Authors:  Jim O'Doherty; Bruno Rojas Fisher; Jonathan Mark Price; Kshama Wechalekar
Journal:  J Nucl Cardiol       Date:  2014-08-01       Impact factor: 5.952

Review 9.  Scintigraphic techniques for early detection of cancer treatment-induced cardiotoxicity.

Authors:  Lioe-Fee de Geus-Oei; Annelies M C Mavinkurve-Groothuis; Louise Bellersen; Martin Gotthardt; Wim J G Oyen; Livia Kapusta; Hanneke W M van Laarhoven
Journal:  J Nucl Med Technol       Date:  2013-08-08

10.  Congestive heart failure and left ventricular dysfunction complicating doxorubicin therapy. Seven-year experience using serial radionuclide angiocardiography.

Authors:  R G Schwartz; W B McKenzie; J Alexander; P Sager; A D'Souza; A Manatunga; P E Schwartz; H J Berger; J Setaro; L Surkin
Journal:  Am J Med       Date:  1987-06       Impact factor: 4.965

View more
  4 in total

1.  Equilibrium gated radionuclide angiocardiography: Its invention, rise, and decline and … comeback?

Authors:  Frans J Th Wackers
Journal:  J Nucl Cardiol       Date:  2016-01-27       Impact factor: 5.952

2.  Left ventricular ejection fraction determined with the simulation of a very low-dose CZT-SPECT protocol and an additional count-calibration on planar radionuclide angiographic data.

Authors:  Hubert Tissot; Véronique Roch; Olivier Morel; Nicolas Veran; Mathieu Perrin; Marine Claudin; Antoine Verger; Gilles Karcher; Pierre-Yves Marie; Laetitia Imbert
Journal:  J Nucl Cardiol       Date:  2019-02-27       Impact factor: 5.952

3.  Applying a correction factor to gated blood pool SPECT left ejection fraction value: Can this approach be used to get around a longstanding hurdle?

Authors:  Sylvain Prévost; Etienne Rousseau
Journal:  J Nucl Cardiol       Date:  2019-03-04       Impact factor: 5.952

4.  Low-dose dobutamine stress gated blood pool SPECT assessment of left ventricular contractile reserve in ischemic cardiomyopathy: a feasibility study.

Authors:  Vladimir V Shipulin; Sergey L Andreev; Andrew S Pryakhin; Andrew V Mochula; Alina N Maltseva; Svetlana I Sazonova; Vladimir M Shipulin; Samia Massalha; Konstantin V Zavadovsky
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-02-12       Impact factor: 10.057

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.