Planar imaging versus gated blood-pool SPECT for the assessment of ventricular performance: a multicenter study.

M W Groch1, E G DePuey, A C Belzberg, W D Erwin, M Kamran, C A Barnett, R C Hendel, S M Spies, A Ali, R C Marshall.   

Abstract

UNLABELLED: Gated blood-pool SPECT (GBPS), inherently 3-dimensional (3D), has the potential to replace planar equilibrium radionuclide angiography (ERNA) for computation of left ventricular ejection fraction (LVEF), analysis of regional wall motion (RWM), and analysis of right heart function. The purpose of this study was to compare GBPS and ERNA for the assessment of ventricular function in a large, multicenter cohort of patients.
METHODS: One hundred seventy-eight patients referred in the usual manner for nuclear medicine studies underwent ERNA followed by GBPS. Each clinical site followed a GBPS acquisition protocol that included 180 degrees rotation, a 64 by 64 matrix, and 64 or 32 views using single- or double-head cameras. Transverse GBPS images were reconstructed with a Butterworth filter (cutoff frequency, 0.45-0.55 Nyquist; order, 7), and short-axis images were created. All GBPS studies were processed with a new GBPS program, and LVEF was computed from the isolated left ventricular chamber and compared with standard ERNA LVEF. Reproducibility of GBPS LVEF was evaluated, and right ventricular ejection fraction (RVEF) was computed in a subset of patients (n = 33). Using GBPS, RWM and image quality from 3D surface-shaded and volume-rendered cine displays were evaluated qualitatively in a subset of patients (n = 30).
RESULTS: The correlation between GBPS LVEF and planar LVEF was excellent (r = 0.92). Mean LVEF was 62.2% for GBPS and 54.1% for ERNA. The line of linear regression was GBPS LVEF = (1.04 x ERNA LVEF) + 6.1. Bland-Altman plotting revealed an increasing bias in GBPS LVEF with increasing LVEF (Y = 0.13x + 0.61; r = 0.30; mean difference = 8.1% +/- 7.0%). Interoperator reproducibility of GBPS LVEF was good (r = 0.92). RVEF values averaged 59.8%. RWM assessment using 3D cine display was enhanced in 27% of the studies, equivalent in 67%, and inferior in 7%.
CONCLUSION: GBPS LVEF was reproducible and correlated well with planar ERNA. GBPS LVEF values were somewhat higher than planar ERNA, likely because of the exclusion of the left atrium.

Entities:  

Mesh:

Year:  2001        PMID: 11752072

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  26 in total

1.  Gated blood pool tomoscintigraphy with 4-dimensional optical flow motion analysis quantifies left ventricular mechanical activation and synchronization.

Authors:  Claudia Dinu; Gregory Klein; Sophie Morestin-Cadet; Marc Froissart; Benoît Diebold; Jean-Yves LeHeuzey; Michel Paillard; Thomas Lavergne; Jean-François Toussaint
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

2.  SPECT versus planar gated blood pool imaging for left ventricular evaluation.

Authors:  François Harel; Vincent Finnerty; Quam Ngo; Jean Grégoire; Paul Khairy; Bernard Thibault
Journal:  J Nucl Cardiol       Date:  2007-06-27       Impact factor: 5.952

3.  Clinical validation of the gated blood pool SPECT QBS processing software in congestive heart failure patients: correlation with MUGA, first-pass RNV and 2D-echocardiography.

Authors:  Marcus Hacker; Xaver Hoyer; Sandra Kupzyk; Christian La Fougere; Johann Kois; Hans-Ulrich Stempfle; Reinhold Tiling; Klaus Hahn; Stefan Störk
Journal:  Int J Cardiovasc Imaging       Date:  2005-11-22       Impact factor: 2.357

Review 4.  SPECT radionuclide angiography: it is time for a consensus statement.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-11       Impact factor: 9.236

5.  Gated tomographic radionuclide angiography using cadmium-zinc-telluride detector gamma camera; comparison to traditional gamma cameras.

Authors:  Maria Maj Jensen; Ulla Schmidt; Chenxi Huang; Bo Zerahn
Journal:  J Nucl Cardiol       Date:  2013-12-24       Impact factor: 5.952

Review 6.  Cardiotoxicity due to chemotherapy: role of cardiac imaging.

Authors:  Frédéric Poulin; Paaladinesh Thavendiranathan
Journal:  Curr Cardiol Rep       Date:  2015-03       Impact factor: 2.931

7.  Comparative study of quantitative blood pool SPECT imaging with 180 degrees and 360 degrees acquisition orbits on accuracy of cardiac function.

Authors:  Itaru Adachi; Tatsuya Umeda; Hiroaki Shimomura; Michihiro Suwa; Tsuyoshi Komori; Yasuharu Ogura; Keita Utsunomiya; Yasushi Kitaura; Isamu Narabayashi
Journal:  J Nucl Cardiol       Date:  2005 Mar-Apr       Impact factor: 5.952

8.  Dose-optimization in nuclear cardiac imaging, time for the next step?

Authors:  Joris D van Dijk
Journal:  J Nucl Cardiol       Date:  2018-09-14       Impact factor: 5.952

9.  Comparison of biventricular ejection fractions using cadmium-zinc-telluride SPECT and planar equilibrium radionuclide angiography.

Authors:  Yi-Chieh Chen; Chi-Lun Ko; Rouh-Fang Yen; Mei-Fang Lo; Yih-Hwen Huang; Pei-Ying Hsu; Yen-Wen Wu; Mei-Fang Cheng
Journal:  J Nucl Cardiol       Date:  2016-03-08       Impact factor: 5.952

10.  Comparison of interstudy reproducibility of equilibrium electrocardiography-gated SPECT radionuclide angiography versus planar radionuclide angiography for the quantification of global left ventricular function.

Authors:  Doumit Daou; Carlos Coaguila; Abdel Benada
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.