Literature DB >> 16015439

Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT.

Seong-Jang Kim1, In-Ju Kim, Yun-Seong Kim, Yong-Ki Kim.   

Abstract

UNLABELLED: Gated blood pool SPECT (GBPS) is an alternative to planar radionuclide ventriculography (PRNV) and offers potential advantages. The aim of this study was to compare 8 and 16 frame GBPS for the determination of left ventricular ejection fraction(LVEF) and left ventricular volumes (LV) in subjects underwent two consecutive GBPS.
METHOD: About 66 consecutive patients (30 men, 36 women; mean age 62.3 +/- 10.4 years) referred for PRNV for evaluation of preoperative cardiac risk stratification (n = 40), prechemotherapy cardiac function evaluation (n = 18, breast cancer), and congestive heart failure patients (n = 8). All patients underwent PRNV of 16 frame and GBPS with both of 8 and 16 frame.
RESULTS: The mean LVEF calculated with PRNV (58.3 +/- 16.8), showed statistically lower than 8-GBPS (70.6 +/- 17.7), and 16-GBPS (69.9 +/- 16.8) (PRNV vs. 8-GBPS, p < 0.01; PRNV vs 16-GBPS, p < 0.01; 8-GBPS vs 16-GBPS, p > 0.05). The correlation of LVEFS between 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9194 (p < 0.01, 95% CI = 0.8712-0.9500). The mean left ventricular end-diastolic volumes (EDV) calculated with 8-GBPS (83.2 +/- 33.5 ml), and 16-GBPS (88.4 +/- 36.8 ml) showed no statistical differences (p > 0.05). The mean left ventricular end-systolic volumes (ESV) calculated with 8-GBPS (28.1 +/- 31.4 ml), and 16-GBPS (30.5 +/- 33 ml) showed also no statistical differences (p > 0.05). Comparison of EDV from 8 and 16-GBPS yielded a correlation coefficient of 0.7430 (p < 0.01, 95% CI = 0.6108-0.8349). The correlation between ESV of 8-GBPS and 16-GBPS showed a correlation coefficient of 0.9522 (p < 0.01, 95% CI = 0.9228-0.9705).
CONCLUSION: This study demonstrated that the LVEFs of 8-GBPS correlated well with that of 16-GBPS. The LVEF of PRNV was significantly lower than those of 8 and 16-GBPS. Also, left ventricular EDV and ESV of 8-GBPS correlated well with those of 16-GBPS. Also, further studies, involving large lumber patients, should be performed to validate the usefulness of GBPS for the evaluation of left ventricular diastolic function.

Entities:  

Mesh:

Year:  2005        PMID: 16015439     DOI: 10.1007/s10554-004-6133-0

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  12 in total

1.  Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT.

Authors:  S D Van Kriekinge; D S Berman; G Germano
Journal:  J Nucl Cardiol       Date:  1999 Sep-Oct       Impact factor: 5.952

2.  Electrocardiographically gated blood-pool SPECT and left ventricular function: comparative value of 3 methods for ejection fraction and volume estimation.

Authors:  D Daou; F Harel; B O Helal; T Fourme; P Colin; R Lebtahi; D Mariano-Goulart; M Faraggi; M Slama; D Le Guludec
Journal:  J Nucl Med       Date:  2001-07       Impact factor: 10.057

3.  Left ventricular ejection fraction and volumes from gated blood-pool SPECT: comparison with planar gated blood-pool imaging and assessment of repeatability in patients with heart failure.

Authors:  Graham A Wright; Simon Thackray; Syd Howey; John G Cleland
Journal:  J Nucl Med       Date:  2003-04       Impact factor: 10.057

4.  Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function.

Authors:  Doumit Daou; Didier Vilain; Patrice Colin; Rachida Lebtahi; Thierry Fourme; Carlos Coaguila; Abdel Benada; Ilana Idy-Peretti; Michel Slama; Dominique Le Guludec
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-04       Impact factor: 9.236

5.  Left ventricular ejection fraction: comparison of results from planar and SPECT gated blood-pool studies.

Authors:  M L Bartlett; G Srinivasan; W C Barker; A N Kitsiou; V Dilsizian; S L Bacharach
Journal:  J Nucl Med       Date:  1996-11       Impact factor: 10.057

6.  Tomographic gated blood pool radionuclide ventriculography: analysis of wall motion and left ventricular volumes in patients with coronary artery disease.

Authors:  J R Corbett; D E Jansen; S E Lewis; G I Gabliani; P Nicod; N G Filipchuk; G A Redish; M S Akers; C L Wolfe; J S Rellas
Journal:  J Am Coll Cardiol       Date:  1985-08       Impact factor: 24.094

7.  ECG-gated emission computed tomography of the cardiac blood pool.

Authors:  M L Moore; P H Murphy; J A Burdine
Journal:  Radiology       Date:  1980-01       Impact factor: 11.105

8.  Reproducibility of equilibrium radionuclide ventriculography in patients with coronary artery disease: response of left ventricular ejection fraction and regional wall motion to supine bicycle exercise.

Authors:  H S Hecht; M A Josephson; J M Hopkins; B N Singh
Journal:  Am Heart J       Date:  1982-09       Impact factor: 4.749

9.  Automatic determination of left ventricular ejection fraction from gated blood-pool tomography.

Authors:  C Vanhove; P R Franken; M Defrise; A Momen; H Everaert; A Bossuyt
Journal:  J Nucl Med       Date:  2001-03       Impact factor: 10.057

10.  Improved left ventricular diastolic filling in patients with coronary artery disease after percutaneous transluminal coronary angioplasty.

Authors:  R O Bonow; K M Kent; D R Rosing; L C Lipson; S L Bacharach; M V Green; S E Epstein
Journal:  Circulation       Date:  1982-12       Impact factor: 29.690

View more
  8 in total

1.  Clinical validation of the gated blood pool SPECT QBS processing software in congestive heart failure patients: correlation with MUGA, first-pass RNV and 2D-echocardiography.

Authors:  Marcus Hacker; Xaver Hoyer; Sandra Kupzyk; Christian La Fougere; Johann Kois; Hans-Ulrich Stempfle; Reinhold Tiling; Klaus Hahn; Stefan Störk
Journal:  Int J Cardiovasc Imaging       Date:  2005-11-22       Impact factor: 2.357

Review 2.  SPECT radionuclide angiography: it is time for a consensus statement.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-11       Impact factor: 9.236

3.  Gated blood pool SPECT: The estimation of right ventricular volume and function is algorithm dependent in a clinical setting.

Authors:  Laurent Dercle; Monia Ouali; Pierre Pascal; Thomas Giraudmaillet; Roland Chisin; Olivier Lairez; Marie-Agnès Marachet; Hervé Rousseau; Delphine Bastié; Fayçal Ben Bouallègue; Isabelle Berry
Journal:  J Nucl Cardiol       Date:  2015-02-20       Impact factor: 5.952

4.  Is TOMPOOL (gated blood-pool SPECT processing software) accurate to diagnose right and left ventricular dysfunction in a clinical setting?

Authors:  Laurent Dercle; Thomas Giraudmaillet; Pierre Pascal; Olivier Lairez; Roland Chisin; Marie-Agnès Marachet; Monia Ouali; Hervé Rousseau; Delphine Bastié; Isabelle Berry
Journal:  J Nucl Cardiol       Date:  2014-05-30       Impact factor: 5.952

5.  Comparison of biventricular ejection fractions using cadmium-zinc-telluride SPECT and planar equilibrium radionuclide angiography.

Authors:  Yi-Chieh Chen; Chi-Lun Ko; Rouh-Fang Yen; Mei-Fang Lo; Yih-Hwen Huang; Pei-Ying Hsu; Yen-Wen Wu; Mei-Fang Cheng
Journal:  J Nucl Cardiol       Date:  2016-03-08       Impact factor: 5.952

6.  Assessment of an intermediate reprojection technique transitioning from planar to SPECT radionuclide ventriculography.

Authors:  Jim O'Doherty; Bruno Rojas Fisher; Jonathan Mark Price; Kshama Wechalekar
Journal:  J Nucl Cardiol       Date:  2014-08-01       Impact factor: 5.952

7.  Comparison of left ventricular ejection fraction values obtained using invasive contrast left ventriculography, two-dimensional echocardiography, and gated single-photon emission computed tomography.

Authors:  Nadish Garg; Thomas Dresser; Kul Aggarwal; Vishal Gupta; Mayank K Mittal; Martin A Alpert
Journal:  SAGE Open Med       Date:  2016-06-24

8.  In vivo positron emission tomographic blood pool imaging in an immunodeficient mouse model using 18F-fluorodeoxyglucose labeled human erythrocytes.

Authors:  Jung W Choi; Mikalai Budzevich; Shaowei Wang; Kenneth Gage; Veronica Estrella; Robert J Gillies
Journal:  PLoS One       Date:  2019-01-25       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.