Literature DB >> 24980073

Interstudy repeatability of left and right ventricular volume estimations by serial-gated tomographic radionuclide angiographies using a cadmium-zinc-telluride detector gamma camera.

Maria M Jensen1, Christine Haase1, Bo Zerahn1.   

Abstract

PURPOSE: Estimation of left ventricular ejection fraction (LVEF) with 99MTc-HSA equilibrium radionuclide angiography (RA) is frequently used for assessing cardiac function. The purpose of this study was to investigate the interstudy repeatability of left (LV) and right (RV) ventricular volume and ejection fraction estimations, using a cadmium-zinc-telluride (CZT) SPECT camera.
MATERIALS AND METHODS: Forty-six patients were scanned twice, interrupted by repositioning. Each acquisition was analysed twice by two experienced technologists. Interstudy and interobserver variations were calculated as the coefficient of variation (CV) and the 95% confidence interval (CI) for limits of agreement (LOA) between each sequence of analyses for each of the two acquisitions.
RESULTS: The Interstudy variations and 95% CI for LVEF, LV end systolic (LVESV) and end diastolic (LVEDV) volumes were 4.6% (-5.4 to 6.4), 9.3% (-6.90 to 5.20) and 7.0% (-13.9 to 11.1), respectively. For the right ventricle, the corresponding values were 11.9% (-9.40 to 10.8), 9.8% (-14.9 to 10.8) and 8.1% (-20.7 to 16.3). DISCUSSION: The CZT detector camera has excellent reproducibility with regard to interstudy variation when assessing LV volumes and EF. Interstudy variation is considerably higher for RV volumes and EF, indicating a lack of consistency in tracing the boarders of the right ventricle.
© 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  SPECT; left ventricular ejection fraction; radionuclide angiography; right ventricular ejection fraction; ventriculography

Mesh:

Substances:

Year:  2014        PMID: 24980073     DOI: 10.1111/cpf.12178

Source DB:  PubMed          Journal:  Clin Physiol Funct Imaging        ISSN: 1475-0961            Impact factor:   2.273


  6 in total

1.  Left ventricular ejection fraction determined with the simulation of a very low-dose CZT-SPECT protocol and an additional count-calibration on planar radionuclide angiographic data.

Authors:  Hubert Tissot; Véronique Roch; Olivier Morel; Nicolas Veran; Mathieu Perrin; Marine Claudin; Antoine Verger; Gilles Karcher; Pierre-Yves Marie; Laetitia Imbert
Journal:  J Nucl Cardiol       Date:  2019-02-27       Impact factor: 5.952

2.  Applying a correction factor to gated blood pool SPECT left ejection fraction value: Can this approach be used to get around a longstanding hurdle?

Authors:  Sylvain Prévost; Etienne Rousseau
Journal:  J Nucl Cardiol       Date:  2019-03-04       Impact factor: 5.952

3.  Comparison of biventricular ejection fractions using cadmium-zinc-telluride SPECT and planar equilibrium radionuclide angiography.

Authors:  Yi-Chieh Chen; Chi-Lun Ko; Rouh-Fang Yen; Mei-Fang Lo; Yih-Hwen Huang; Pei-Ying Hsu; Yen-Wen Wu; Mei-Fang Cheng
Journal:  J Nucl Cardiol       Date:  2016-03-08       Impact factor: 5.952

4.  Pre-chemotherapy values for left and right ventricular volumes and ejection fraction by gated tomographic radionuclide angiography using a cadmium-zinc-telluride detector gamma camera.

Authors:  Christian Haarmark; Christine Haase; Maria Maj Jensen; Bo Zerahn
Journal:  J Nucl Cardiol       Date:  2015-09-04       Impact factor: 5.952

5.  Radiation reduction and faster acquisition times with SPECT gated blood pool scans using a high-efficiency cardiac SPECT camera.

Authors:  W Lane Duvall; Krista A Guma-Demers; Titus George; Milena J Henzlova
Journal:  J Nucl Cardiol       Date:  2015-08-01       Impact factor: 5.952

6.  An Algorithm for Individual Dosage in Cadmium-Zinc-Telluride SPECT-Gated Radionuclide Angiography.

Authors:  Maria Normand Hansen; Christian Haarmark; Bent Kristensen; Bo Zerahn
Journal:  Diagnostics (Basel)       Date:  2021-12-04
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.