Jong-Ryoul Kim1, Sung-Hee Kim2, In-Ryoung Kim3, Bong-Soo Park3, Yong-Deok Kim4.
Abstract
OBJECTIVES: The purpose of this study was to investigate the effects of low-level laser therapy (LLLT) with a diode gallium-aluminum-arsenide (Ga-Al-As) low-level laser device on the healing and attachment of titanium implants in bone.Entities:
Keywords: Animal experiments; Bone density; Dental implants; Lasers; Titanium
Year: 2016 PMID: 26904488 PMCID: PMC4761568 DOI: 10.5125/jkaoms.2016.42.1.2
Source DB: PubMed Journal: J Korean Assoc Oral Maxillofac Surg ISSN: 1225-1585
Fig. 1Differences between old lamellar bone, at a distance >1 mm from the implant surface, and new bone (arrowheads) formation all along the implant surface. Microphotograph at 6 weeks after implantation (H&E staining, ×100) in the control group (A) and the low-level laser therapy (LLLT) group (B). Microphotograph at 12 weeks after implantation (H&E staining, ×100) in the control group (C) and the LLLT group (D).
Fig. 2Differences between old lamellar bone, at a distance >1 mm from the implant surface, and new bone (arrowheads) formation along the implant surface. Microphotograph at 6 weeks after implantation (Masson's trichrome staining, ×100) in the control group (A) and the low-level laser therapy (LLLT) group (B). Microphotograph at 12 weeks after implantation (Masson's trichrome staining, ×100) in the control group (C) and the LLLT group (D).
Fig. 3Mean bone-to-implant contact (BIC) ratio in the control group and the low-level laser therapy (LLLT) group.
Descriptive statistics of removal torque value according to two groups and healing time
| Group | Removal torque value (cNm) | |
|---|---|---|
| 6 wk | 12 wk | |
| Control group | 60.0±32.5 | 37.4±6.1 |
| LLLT group | 54.1±4.3 | 90.0±21.1* |
(LLLT: low-level laser therapy)
*P≤0.05.
LLLT group was treated with LLLT for one week after the surgery and control group was not treated with LLLT.
Removal torque values in the control group and LLLT group at different time intervals postsurgery.
Values are presented as mean±standard deviation.
Descriptive statistics of ISQ, dif. % ISQ according to two groups and healing time
| Group | 6 wk | 12 wk | |
|---|---|---|---|
| Control group | ISQ | 68.3±15.5 | 73.3±6.6 |
| dif. % ISQ | 39.1±5.3 | 29.3±28.9 | |
| LLLT group | ISQ | 69.0±10.0 | 65.7±9.7 |
| dif. % ISQ | 29.7±32.0 | -10.9±29.1* |
(ISQ: implant stability quotient, dif. % ISQ: converted into a percentage for the difference values between final ISQ and initial ISQ, LLLT: low-level laser therapy)
*P≤0.05.
LLLT group was treated with LLLT for one week after the surgery and control group was not treated with LLLT.
ISQ, dif. % ISQ in the control group and LLLT group at different time intervals postsurgery.
Values are presented as mean±standard deviation.