Literature DB >> 26900358

Analyzing the performance of ArcCHECK diode array detector for VMAT plan.

Rajesh Thiyagarajan1, Arunai Nambiraj2, Sujit Nath Sinha3, Girigesh Yadav3, Ashok Kumar3, Vikraman Subramani1.   

Abstract

AIM: The aim of this study is to evaluate performance of ArcCHECK diode array detector for the volumetric modulated arc therapy (VMAT) patient specific quality assurance (QA). VMAT patient specific QA results were correlated with ion chamber measurement. Dose response of the ArcCHECK detector was studied.
BACKGROUND: VMAT delivery technique improves the dose distribution. It is complex in nature and requires proper QA before its clinical implementation. ArcCHECK is a novel three dimensional dosimetry system.
MATERIALS AND METHODS: Twelve retrospective VMAT plans were calculated on ArcCHECK phantom. Point dose and dose map were measured simultaneously with ion chamber (IC-15) and ArcCHECK diode array detector, respectively. These measurements were compared with their respective TPS calculated values.
RESULTS: The ion chamber measurements are in good agreement with TPS calculated doses. Mean difference between them is 0.50% with standard deviation of 0.51%. Concordance correlation coefficient (CCC) obtained for ion chamber measurements is 0.9996. These results demonstrate a strong correlation between the absolute dose predicted by our TPS and the measured dose. The CCC between ArcCHECK doses and TPS predictions on the CAX was found to be 0.9978. In gamma analysis of dose map, the mean passing rate was 98.53% for 3% dose difference and 3 mm distance to agreement.
CONCLUSIONS: The VMAT patient specific QA with an ion chamber and ArcCHECK phantom are consistent with the TPS calculated dose. Statistically good agreement was observed between ArcCHECK measured and TPS calculated. Hence, it can be used for routine VMAT QA.

Entities:  

Keywords:  ArcCHECK; Diode array; Gamma; Quality assurance; VMAT

Year:  2015        PMID: 26900358      PMCID: PMC4716405          DOI: 10.1016/j.rpor.2015.10.004

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  28 in total

1.  Intensity modulated arc deliveries approximated by a large number of fixed gantry position sliding window dynamic multileaf collimator fields.

Authors:  Marc A MacKenzie; Donald M Robinson
Journal:  Med Phys       Date:  2002-10       Impact factor: 4.071

2.  Optimizing the accuracy of a helical diode array dosimeter: a comprehensive calibration methodology coupled with a novel virtual inclinometer.

Authors:  Jakub Kozelka; Joshua Robinson; Benjamin Nelms; Geoffrey Zhang; Dennis Savitskij; Vladimir Feygelman
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

3.  Comparing radiation treatments using intensity-modulated beams, multiple arcs, and single arcs.

Authors:  Grace Tang; Matthew A Earl; Shuang Luan; Chao Wang; Majid M Mohiuddin; Cedric X Yu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-04       Impact factor: 7.038

4.  Sweeping-window arc therapy: an implementation of rotational IMRT with automatic beam-weight calculation.

Authors:  C Cameron
Journal:  Phys Med Biol       Date:  2005-09-07       Impact factor: 3.609

5.  Leaf-sequencing for intensity-modulated arc therapy using graph algorithms.

Authors:  Shuang Luan; Chao Wang; Daliang Cao; Danny Z Chen; David M Shepard; Cedric X Yu
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

6.  Volumetric modulated arc therapy: IMRT in a single gantry arc.

Authors:  Karl Otto
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

7.  Arc-modulated radiation therapy (AMRT): a single-arc form of intensity-modulated arc therapy.

Authors:  Chao Wang; Shuang Luan; Grace Tang; Danny Z Chen; Matt A Earl; Cedric X Yu
Journal:  Phys Med Biol       Date:  2008-10-20       Impact factor: 3.609

8.  Involved-node and involved-field volumetric modulated arc vs. fixed beam intensity-modulated radiotherapy for female patients with early-stage supra-diaphragmatic Hodgkin lymphoma: a comparative planning study.

Authors:  Damien C Weber; Nicolas Peguret; Giovanna Dipasquale; Luca Cozzi
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-12-01       Impact factor: 7.038

9.  Treatment planning and dosimetric comparison study on two different volumetric modulated arc therapy delivery techniques.

Authors:  S A Syam Kumar; Raghavendra Holla; Prabakar Sukumar; Sriram Padmanaban; Nagarajan Vivekanandan
Journal:  Rep Pract Oncol Radiother       Date:  2012-08-09

10.  Intensity modulation with photons for benign intracranial tumours: a planning comparison of volumetric single arc, helical arc and fixed gantry techniques.

Authors:  Antonella Fogliata; Alessandro Clivio; Giorgia Nicolini; Eugenio Vanetti; Luca Cozzi
Journal:  Radiother Oncol       Date:  2008-08-28       Impact factor: 6.280

View more
  7 in total

1.  Volumetric-modulated arc therapy using multicriteria optimization for body and extremity sarcoma.

Authors:  Michael R Young; David L Craft; Caroline M Colbert; Kyla Remillard; Liam Vanbenthuysen; Yi Wang
Journal:  J Appl Clin Med Phys       Date:  2016-11-08       Impact factor: 2.102

2.  Validation of the RapidArc Delivery System Using a Volumetric Phantom as Per Task Group Report 119 of the American Association of Physicists in Medicine.

Authors:  Lalit Kumar; Girigesh Yadav; Vimal Kishore; Manindra Bhushan; Munish Gairola; Deepak Tripathi
Journal:  J Med Phys       Date:  2019 Apr-Jun

3.  Statistical Analysis of Treatment Planning Parameters for Prediction of Delivery Quality Assurance Failure for Helical Tomotherapy.

Authors:  Kyung Hwan Chang; Young Hyun Lee; Byung Hun Park; Min Cheol Han; Jihun Kim; Hojin Kim; Min-Seok Cho; Hyokyeong Kang; Ho Lee; Dong Wook Kim; Kwangwoo Park; Jaeho Cho; Yong Bae Kim; Jin Sung Kim; Chae-Seon Hong
Journal:  Technol Cancer Res Treat       Date:  2020 Jan-Dec

4.  Interinstitutional beam model portability study in a mixed vendor environment.

Authors:  Sean P Frigo; Jared Ohrt; Yelin Suh; Peter Balter
Journal:  J Appl Clin Med Phys       Date:  2021-10-13       Impact factor: 2.102

5.  Dosimetric effect of limited aperture multileaf collimator on VMAT plan quality: A study of prostate and head-and-neck cancers.

Authors:  Ghulam Murtaza; Shahid Mehmood; Shahid Rasul; Imran Murtaza; Ehsan Ullah Khan
Journal:  Rep Pract Oncol Radiother       Date:  2018-03-21

6.  Simplification of head and neck volumetric modulated arc therapy patient-specific quality assurance, using a Delta4 PT.

Authors:  Motoharu Sasaki; Wataru Sugimoto; Hitoshi Ikushima
Journal:  Rep Pract Oncol Radiother       Date:  2020-08-08

7.  Retrospective dosimetry study of intensity-modulated radiation therapy for nasopharyngeal carcinoma: measurement-guided dose reconstruction and analysis.

Authors:  Wen-Zhao Sun; Dan-Dan Zhang; Ying-Lin Peng; Li Chen; De-Hua Kang; Bin Wang; Xiao-Wu Deng
Journal:  Radiat Oncol       Date:  2018-03-15       Impact factor: 3.481

  7 in total