Literature DB >> 24416535

Treatment planning and dosimetric comparison study on two different volumetric modulated arc therapy delivery techniques.

S A Syam Kumar1, Raghavendra Holla2, Prabakar Sukumar1, Sriram Padmanaban1, Nagarajan Vivekanandan1.   

Abstract

AIM: To compare and evaluate the performance of two different volumetric modulated arc therapy delivery techniques.
BACKGROUND: Volumetric modulated arc therapy is a novel technique that has recently been made available for clinical use. Planning and dosimetric comparison study was done for Elekta VMAT and Varian RapidArc for different treatment sites.
MATERIALS AND METHODS: Ten patients were selected for the planning comparison study. This includes 2 head and neck, 2 oesophagus, 1 bladder, 3 cervix and 2 rectum cases. Total dose of 50 Gy was given for all the plans. All plans were done for RapidArc using Eclipse and for Elekta VMAT with Monaco treatment planning system. All plans were generated with 6 MV X-rays for both RapidArc and Elekta VMAT. Plans were evaluated based on the ability to meet the dose volume histogram, dose homogeneity index, radiation conformity index, estimated radiation delivery time, integral dose and monitor units needed to deliver the prescribed dose.
RESULTS: RapidArc plans achieved the best conformity (CI95% = 1.08 ± 0.07) while Elekta VMAT plans were slightly inferior (CI95% = 1.10 ± 0.05). The in-homogeneity in the PTV was highest with Elekta VMAT with HI equal to 0.12 ± 0.02 Gy when compared to RapidArc with 0.08 ± 0.03. Significant changes were observed between the RapidArc and Elekta VMAT plans in terms of the healthy tissue mean dose and integral dose. Elekta VMAT plans show a reduction in the healthy tissue mean dose (6.92 ± 2.90) Gy when compared to RapidArc (7.83 ± 3.31) Gy. The integral dose is found to be inferior with Elekta VMAT (11.50 ± 6.49) × 10(4) Gy cm(3) when compared to RapidArc (13.11 ± 7.52) × 10(4) Gy cm(3). Both Varian RapidArc and Elekta VMAT respected the planning objective for all organs at risk. Gamma analysis result for the pre-treatment quality assurance shows good agreement between the planned and delivered fluence for 3 mm DTA, 3% DD for all the evaluated points inside the PTV, for both VMAT and RapidArc techniques.
CONCLUSION: The study concludes that a variable gantry speed with variable dose rate is important for efficient arc therapy delivery. RapidArc presents a slight improvement in the OAR sparing with better target coverage when compared to Elekta VMAT. Trivial differences were noted in all the plans for organ at risk but the two techniques provided satisfactory conformal avoidance and conformation.

Entities:  

Keywords:  Elekta VMAT; Planning study; Varian RapidArc

Year:  2012        PMID: 24416535      PMCID: PMC3863293          DOI: 10.1016/j.rpor.2012.07.008

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  18 in total

1.  Whole abdominopelvic radiotherapy (WAPRT) using intensity-modulated arc therapy (IMAT): first clinical experience.

Authors:  Wim Duthoy; Werner De Gersem; Koen Vergote; Marc Coghe; Tom Boterberg; Yves De Deene; Carlos De Wagter; Simon Van Belle; Wilfried De Neve
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-11-15       Impact factor: 7.038

2.  Clinical implementation of intensity-modulated arc therapy (IMAT) for rectal cancer.

Authors:  Wim Duthoy; Werner De Gersem; Koen Vergote; Tom Boterberg; Cristina Derie; Peter Smeets; Carlos De Wagter; Wilfried De Neve
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-11-01       Impact factor: 7.038

3.  Optimization of collimator trajectory in volumetric modulated arc therapy: development and evaluation for paraspinal SBRT.

Authors:  Pengpeng Zhang; Laura Happersett; Yingli Yang; Yoshiya Yamada; Gig Mageras; Margie Hunt
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-02-19       Impact factor: 7.038

4.  Sweeping-window arc therapy: an implementation of rotational IMRT with automatic beam-weight calculation.

Authors:  C Cameron
Journal:  Phys Med Biol       Date:  2005-09-07       Impact factor: 3.609

5.  Volumetric modulated arc therapy: IMRT in a single gantry arc.

Authors:  Karl Otto
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

6.  Arc-modulated radiation therapy (AMRT): a single-arc form of intensity-modulated arc therapy.

Authors:  Chao Wang; Shuang Luan; Grace Tang; Danny Z Chen; Matt A Earl; Cedric X Yu
Journal:  Phys Med Biol       Date:  2008-10-20       Impact factor: 3.609

7.  Commissioning and quality assurance of RapidArc radiotherapy delivery system.

Authors:  C Clifton Ling; Pengpeng Zhang; Yves Archambault; Jiri Bocanek; Grace Tang; Thomas Losasso
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-10-01       Impact factor: 7.038

8.  Clinical implementation of intensity-modulated arc therapy.

Authors:  Cedric X Yu; X Allen Li; Lijun Ma; Dongjun Chen; Shahid Naqvi; David Shepard; Mehrdad Sarfaraz; Timothy W Holmes; Mohan Suntharalingam; Carl M Mansfield
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-06-01       Impact factor: 7.038

Review 9.  Radiation-induced second cancers: the impact of 3D-CRT and IMRT.

Authors:  Eric J Hall; Cheng-Shie Wuu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-05-01       Impact factor: 7.038

10.  Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy.

Authors:  C X Yu
Journal:  Phys Med Biol       Date:  1995-09       Impact factor: 3.609

View more
  6 in total

1.  How to compare treatment plans? Personalized perspective.

Authors:  Tomasz Piotrowski; Agata Jodda
Journal:  Rep Pract Oncol Radiother       Date:  2014-07-15

2.  Muscle-invasive bladder cancer treated with TURB followed by concomitant boost with small reduction of radiotherapy field with or without of chemotherapy.

Authors:  Jadwiga Nowak-Sadzikowska; Tomasz Skóra; Bogumiła Szyszka-Charewicz; Jerzy Jakubowicz
Journal:  Rep Pract Oncol Radiother       Date:  2015-09-29

3.  Analyzing the performance of ArcCHECK diode array detector for VMAT plan.

Authors:  Rajesh Thiyagarajan; Arunai Nambiraj; Sujit Nath Sinha; Girigesh Yadav; Ashok Kumar; Vikraman Subramani
Journal:  Rep Pract Oncol Radiother       Date:  2015-12-02

4.  Can we obtain planning goals for conformal techniques in neoadjuvant and adjuvant radiochemotherapy for gastric cancer patients?

Authors:  Wojciech Leszczyński; Paweł Polanowski; Paulina Leszczyńska; Leszek Hawrylewicz; Iwona Brąclik; Rafał Kawczyński; Jerzy Wydmański
Journal:  Rep Pract Oncol Radiother       Date:  2016-02-08

Review 5.  Directed differentiation of induced pluripotent stem cells into chondrogenic lineages for articular cartilage treatment.

Authors:  Michał Lach; Tomasz Trzeciak; Magdalena Richter; Jarosław Pawlicz; Wiktoria M Suchorska
Journal:  J Tissue Eng       Date:  2014-09-30       Impact factor: 7.813

6.  Rectal protection in prostate stereotactic radiotherapy: a retrospective exploratory analysis of two rectal displacement devices.

Authors:  Lee Wilton; Matthew Richardson; Sarah Keats; Kimberley Legge; Mary-Claire Hanlon; Sankar Arumugam; Perry Hunter; Tiffany-Jane Evans; Mark Sidhom; Jarad Martin
Journal:  J Med Radiat Sci       Date:  2017-08-08
  6 in total