Literature DB >> 32879621

Simplification of head and neck volumetric modulated arc therapy patient-specific quality assurance, using a Delta4 PT.

Motoharu Sasaki1, Wataru Sugimoto2, Hitoshi Ikushima1.   

Abstract

BACKGROUND/AIM: In many facilities, intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT) use intensity-modulated beams, formed by a multi-leaf collimator (MLC). In IMRT and VMAT, MLC and linear accelerator errors (both geometric and dose), can significantly affect the doses administered to patients. Therefore, IMRT and VMAT treatment plans must include the use of patient-specific quality assurance (QA) before treatment to confirm dose accuracy.
MATERIALS AND METHODS: In this study, we compared and analyzed the results of dose verification using a multi-dimensional dose verification system Delta4 PT, an ionization chamber dosimeter, and gafchromic film, using data from 52 patients undergoing head and neck VMAT as the test material. RESULT: Based on the results of the absolute dose verification for the ionization chamber dosimeter and Delta4 PT, taking an axial view, the upper limit of the 95% confidence interval was 3.13%, and the lower limit was -3.67%, indicating good agreement. These results mean that as long as absolute dose verification for the axial view does not deviate from this range, Delta4 PT can be used as an alternative to an ionization chamber dosimeter for absolute dose verification. When we then reviewed dose distribution verification, the pass rate for Delta4 PT was acceptable, and was less varied than that of gafchromic film.
CONCLUSION: This results in that provided the pass rate result for Delta4 PT does not fall below 96%, it can be used as a substitute for gafchromic film in dose distribution verification. These results indicate that patient-specific QA could be simplified.
© 2020 Greater Poland Cancer Centre. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Delta4 PT; Head and neck; Patient-specific quality assurance; Volumetric modulated radiation therapy

Year:  2020        PMID: 32879621      PMCID: PMC7451711          DOI: 10.1016/j.rpor.2020.07.004

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  13 in total

1.  A pencil beam model for photon dose calculation.

Authors:  A Ahnesjö; M Saxner; A Trepp
Journal:  Med Phys       Date:  1992 Mar-Apr       Impact factor: 4.071

2.  Guidance document on delivery, treatment planning, and clinical implementation of IMRT: report of the IMRT Subcommittee of the AAPM Radiation Therapy Committee.

Authors:  Gary A Ezzell; James M Galvin; Daniel Low; Jatinder R Palta; Isaac Rosen; Michael B Sharpe; Ping Xia; Ying Xiao; Lei Xing; Cedric X Yu
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

3.  Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors.

Authors:  Benjamin E Nelms; Heming Zhen; Wolfgang A Tomé
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

4.  IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119.

Authors:  Gary A Ezzell; Jay W Burmeister; Nesrin Dogan; Thomas J LoSasso; James G Mechalakos; Dimitris Mihailidis; Andrea Molineu; Jatinder R Palta; Chester R Ramsey; Bill J Salter; Jie Shi; Ping Xia; Ning J Yue; Ying Xiao
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

5.  Long-term stability of a three-dimensional dose verification system.

Authors:  Motoharu Sasaki; Hitoshi Ikushima; Wataru Sugimoto; Kenta Kitagawa
Journal:  Radiol Phys Technol       Date:  2020-01-31

Review 6.  Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM Task Group No. 218.

Authors:  Moyed Miften; Arthur Olch; Dimitris Mihailidis; Jean Moran; Todd Pawlicki; Andrea Molineu; Harold Li; Krishni Wijesooriya; Jie Shi; Ping Xia; Nikos Papanikolaou; Daniel A Low
Journal:  Med Phys       Date:  2018-03-23       Impact factor: 4.071

7.  Evaluation of the ArcCHECK QA system for IMRT and VMAT verification.

Authors:  Guangjun Li; Yingjie Zhang; Xiaoqin Jiang; Sen Bai; Guang Peng; Kui Wu; Qingfeng Jiang
Journal:  Phys Med       Date:  2012-05-12       Impact factor: 2.685

8.  Evaluation of semiempirical VMAT dose reconstruction on a patient dataset based on biplanar diode array measurements.

Authors:  Cassandra Stambaugh; Daniel Opp; Stuart Wasserman; Geoffrey Zhang; Vladimir Feygelman
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

9.  Reproducibility in patient-specific IMRT QA.

Authors:  Elizabeth M McKenzie; Peter A Balter; Francesco C Stingo; Jimmy Jones; David S Followill; Stephen F Kry
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

10.  Evaluation of the sensitivity of two 3D diode array dosimetry systems to setup error for quality assurance (QA) of volumetric-modulated arc therapy (VMAT).

Authors:  Guangjun Li; Sen Bai; Nianyong Chen; Lansdale Henderson; Kui Wu; Jianghong Xiao; Yingjie Zhang; Qingfeng Jiang; Xiaoqin Jiang
Journal:  J Appl Clin Med Phys       Date:  2013-09-06       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.