Literature DB >> 26900294

Choledochojejunostomy with an innovative magnetic compressive anastomosis: How to determine optimal pressure?

Fei Xue1, Hong-Chang Guo1, Jian-Peng Li1, Jian-Wen Lu1, Hao-Hua Wang1, Feng Ma1, Ya-Xiong Liu1, Yi Lv1.   

Abstract

AIM: To investigate the optimal magnetic pressure and provide a theoretical basis for choledochojejunostomy magnetic compressive anastomosis (magnamosis).
METHODS: Four groups of neodymium-iron-boron magnets with different magnetic pressures of 0.1, 0.2, 0.3 and 0.4 MPa were used to complete the choledochojejunostomy magnamosis. Twenty-six young mongrel dogs were randomly divided into five groups: four groups with different magnetic pressures and 1 group with a hand-suture anastomosis. Serum bilirubin levels were measured in all groups before and 1 wk, 2 wk, 3 wk, 1 mo and 3 mo after surgery. Daily abdominal X-ray fluoroscopy was carried out postoperatively to detect the path and the excretion of the magnet. The animals were euthanized at 1 or 3 mo after the operation, the burst pressure was detected in each anastomosis, and the gross appearance and histology were compared according to the observation.
RESULTS: The surgical procedures were all successfully performed in animals. However, animals of group D (magnetic pressure of 0.4 MPa) all experienced complications with bile leakage (4/4), whereas half of animals in group A (magnetic pressure of 0.1 MPa) experienced complications (3/6), 1 animal in the manual group E developed anastomotic stenosis, and animals in group B and group C (magnetic pressure of 0.2 MPa and 0.3 MPa, respectively) all healed well without complications. These results also suggested that the time required to form the stoma was inversely proportional to the magnetic pressure; however, the burst pressure of group A was smaller than those of the other groups at 1 mo (187.5 ± 17.7 vs 290 ± 10/296.7 ± 5.7/287.5 ± 3.5, P < 0.05); the remaining groups did not differ significantly. A histologic examination demonstrated obvious differences between the magnamosis groups and the hand-sewn group.
CONCLUSION: We proved that the optimal range for choledochojejunostomy magnamosis is 0.2 MPa to 0.3 MPa, which will help to improve the clinical application of this technique in the future.

Entities:  

Keywords:  Choledochojejunostomy; Magnetic compressive anastomosis; Magnetic pressure; Optimal range; Pressure intensity

Mesh:

Substances:

Year:  2016        PMID: 26900294      PMCID: PMC4735006          DOI: 10.3748/wjg.v22.i7.2326

Source DB:  PubMed          Journal:  World J Gastroenterol        ISSN: 1007-9327            Impact factor:   5.742


  17 in total

1.  [Choledochojejunostomy using a mechanical stapler].

Authors:  R Cirocchi; P Covarelli; M Mazieri; B Fabbri; C Bisacci; C Fabbri; R Bisacci
Journal:  Chir Ital       Date:  1999 Mar-Apr

2.  A novel technique of magnetic compression anastomosis for severe biliary stenosis.

Authors:  Akihiro Mimuro; Akihiko Tsuchida; Eigoro Yamanouchi; Takao Itoi; Takashi Ozawa; Takahisa Ikeda; Ryuji Nakamura; Yasuhisa Koyanagi; Kazuto Nakamura
Journal:  Gastrointest Endosc       Date:  2003-08       Impact factor: 9.427

3.  Non-suture anastomosis: the historical development.

Authors:  K J Hardy
Journal:  Aust N Z J Surg       Date:  1990-08

4.  Clinical experience with the Ventrica distal anastomotic device in coronary surgery.

Authors: 
Journal:  Minim Invasive Ther Allied Technol       Date:  2004-02       Impact factor: 2.442

5.  Use of a metallic-wall stent in the magnet compression anastomosis technique for bile duct obstruction after liver transplantation.

Authors:  Hirofumi Akita; Hayato Hikita; Eigoro Yamanouchi; Shigeru Marubashi; Hiroaki Nagano; Koji Umeshita; Keizo Dono; Shusaku Tsutsui; Norio Hayashi; Morito Monden
Journal:  Liver Transpl       Date:  2008-01       Impact factor: 5.799

6.  Salvage cystic duct anastomosis using a magnetic compression technique for incomplete bile duct reconstruction in living donor liver transplantation.

Authors:  Shigeru Marubashi; Hiroaki Nagano; Eigoro Yamanouchi; Shogo Kobayashi; Hidetoshi Eguchi; Yutaka Takeda; Masahiro Tanemura; Noboru Maeda; Kaname Tomoda; Hayato Hikita; Shusaku Tsutsui; Yuichiro Doki; Masaki Mori
Journal:  Liver Transpl       Date:  2010-01       Impact factor: 5.799

7.  Magnetic compression in gastrointestinal and bilioenteric anastomosis: how much force?

Authors:  Tadhg Lambe; Mícheál G Ó Ríordáin; Ronan A Cahill; Pádraig Cantillon-Murphy
Journal:  Surg Innov       Date:  2013-04-16       Impact factor: 2.058

8.  Magnetic vascular coupling for distal anastomosis in coronary artery bypass grafting: a multicenter trial.

Authors:  Uwe Klima; Volkmar Falk; Michael Maringka; Steffen Bargenda; Steven Badack; Anton Moritz; Friedrich Mohr; Axel Haverich; Gerhard Wimmer-Greinecker
Journal:  J Thorac Cardiovasc Surg       Date:  2003-11       Impact factor: 5.209

9.  Application of a new type of sutureless magnetic biliary-enteric anastomosis stent for one-stage reconstruction of the biliary-enteric continuity after acute bile duct injury: an experimental study.

Authors:  Jianhui Li; Yi Lü; Bo Qu; Zhiyong Zhang; Chang Liu; Yuan Shi; Bo Wang
Journal:  J Surg Res       Date:  2007-10-15       Impact factor: 2.192

10.  Magnamosis: magnetic compression anastomosis with comparison to suture and staple techniques.

Authors:  Ramin Jamshidi; Jacob T Stephenson; Jared G Clay; Kullada O Pichakron; Michael R Harrison
Journal:  J Pediatr Surg       Date:  2009-01       Impact factor: 2.545

View more
  6 in total

1.  Magnetic Anastomosis for Biliojejunostomy: First Prospective Clinical Trial.

Authors:  Xue-Min Liu; Xiao-Peng Yan; Hong-Ke Zhang; Feng Ma; Yan-Guang Guo; Chao Fan; Shan-Pei Wang; Ai-Hua Shi; Bo Wang; Hao-Hua Wang; Jian-Hui Li; Xiao-Gang Zhang; Rongqian Wu; Xu-Feng Zhang; Yi Lv
Journal:  World J Surg       Date:  2018-12       Impact factor: 3.352

2.  Surprising neutral effect of shorter staple cartridges in laparoscopic sleeve gastrectomy.

Authors:  Christen E Salyer; Jonathan Thompson; Dennis Hanseman; Tayyab Diwan; Brad M Watkins; Joshua Kuethe; Michael D Goodman
Journal:  Surg Endosc       Date:  2021-11-12       Impact factor: 3.453

3.  A Rat Model of Orthotopic Liver Transplantation Using a Novel Magnetic Anastomosis Technique for Suprahepatic Vena Cava Reconstruction.

Authors:  Lifei Yang; Jianwen Lu; Yue Wang; Mei Zhang; Yuan Shi; Shasha Wei; Peng Liu; Zheng Wu; Yi Lv; Rongqian Wu
Journal:  J Vis Exp       Date:  2018-03-19       Impact factor: 1.355

4.  Fedora-type magnetic compression anastomosis device for intestinal anastomosis.

Authors:  Huan Chen; Tao Ma; Yue Wang; Hao-Yang Zhu; Zhe Feng; Rong-Qian Wu; Yi Lv; Ding-Hui Dong
Journal:  World J Gastroenterol       Date:  2020-11-14       Impact factor: 5.742

5.  Bile duct reconstruction using scaffold-free tubular constructs created by Bio-3D printer.

Authors:  Takashi Hamada; Anna Nakamura; Akihiko Soyama; Yusuke Sakai; Takayuki Miyoshi; Shun Yamaguchi; Masaaki Hidaka; Takanobu Hara; Tota Kugiyama; Mitsuhisa Takatsuki; Akihide Kamiya; Koichi Nakayama; Susumu Eguchi
Journal:  Regen Ther       Date:  2021-02-24       Impact factor: 3.419

6.  Esophageal magnetic compression anastomosis in dogs.

Authors:  Xiang-Hua Xu; Yi Lv; Shi-Qi Liu; Xiao-Hai Cui; Rui-Yang Suo
Journal:  World J Gastroenterol       Date:  2022-09-28       Impact factor: 5.374

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.