| Literature DB >> 26877989 |
So-Hyun Park1, Yeon-Jee Yoo2, Yoo-Jin Shin2, Byeong-Hoon Cho2, Seung-Ho Baek2.
Abstract
OBJECTIVES: The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations.Entities:
Keywords: Internal gap; Lava ultimate; Marginal gap; Nano-composite CAD/CAM blocks
Year: 2016 PMID: 26877989 PMCID: PMC4751205 DOI: 10.5395/rde.2016.41.1.37
Source DB: PubMed Journal: Restor Dent Endod ISSN: 2234-7658
Figure 1(a, b) Preparation design of nano-composite CAD/CAM restorations. (a) full crown and (b) mesio-occluso-distal inlay with a cusp capping; (c, d) Occlusal view from the yellow boxes of (a) and (b) were used to illustrate the representative diagrams showing the sectioned segments (black boxes) obtained from each specimen of (c) full crowns and (d) inlays; (e, f) Representative diagram showing the measuring points of the internal marginal fit of (e) the full crown and (f) the cusp capping area of the inlay (red arrow in (b)). M, mesial view; D, distal view; B, buccal view; L, lingual view.
Gap measurement of crowns made of two CAD/CAM blocks according to the measuring points (Unit, µm; mean ± standard deviation)
| Block type | |||
|---|---|---|---|
| Experimental block | Lava ultimate | ||
| Measuring point | Occlusal | 252.92 ± 12.51Aa | 195.57 ± 6.92Ba |
| Axial | 104.82 ± 7.07Bc | 123.63 ± 8.36Ab | |
| Transitional | 162.87 ± 8.89Ab | 111.73 ± 7.16Bc | |
| Marginal | 57.65 ± 4.10Ad | 50.18 ± 3.39Bd | |
| Overall | 144.57 ± 73.48A | 120.42 ± 51.98B | |
Values with the same uppercase superscript letters within the same row are not significantly different between the two composite resin CAD/CAM blocks (p > 0.05).
Values with the same lowercase superscript letters within the same column are not significantly different among the measuring points (p > 0.05).
Gap measurement of inlays made of two CAD/CAM blocks according to the measuring points (Unit, µm; mean ± standard deviation)
| Block type | ||||
|---|---|---|---|---|
| Experimental block | Lava ultimate | |||
| Whole cavity | Occlusal | 219.76 ± 6.52Aα | 175.44 ± 5.85Bα | |
| Axial | 142.47 ± 9.05Aβ | 111.05 ± 5.29Bβ | ||
| Transitional | 138.64 ± 11.25Aγ | 102.78 ± 8.23Bγ | ||
| Measuring point | Mesio-occluso-distal cavity | Occlusal | 222.50 ± 10.38Aa | 164.34 ± 6.29Bb |
| Axial | 144.33 ± 13.97Ad | 131.34 ± 6.60Bc | ||
| Transitional | 118.86 ± 5.92Af | 103.20 ± 6.98Bd | ||
| Cusp capping area | Occlusal | 216.49 ± 10.38Ab | 186.54 ± 10.52Ba | |
| Axial | 140.60 ± 8.86Ae | 90.76 ± 8.35Be | ||
| Transitional | 173.78 ± 13.38Ac | 102.33 ± 9.33Bd | ||
| Marginal | 55.27 ± 6.40Ag | 48.72 ± 4.07Bf | ||
| Overall | 149.76 ± 58.36A | 120.82 ± 46.72B | ||
Values with the same uppercase superscript letters within the same row are not significantly different between the two composite resin CAD/CAM blocks (p > 0.05).
Values with the same lowercase superscript letters within the same column are not significantly different among the measuring points (p > 0.05).
Values with the same greek superscript letters within the same column of the 'whole cavity' row are not significantly different among the measuring points (p > 0.05).