Literature DB >> 26855940

Rotational alignment of the femoral component in total knee arthroplasty.

Claudio Carlo Castelli1, Daniele Antonio Falvo1, Mario Luigi Iapicca1, Valerio Gotti1.   

Abstract

We describe here various surgical options to obtain a correct rotational alignment of femoral component in total knee arthroplasty (TKA). The correct rotational alignment is the key point to obtain a rectangular balanced flexion gap as well to have a good patellar tracking. For that reason, rotation alignment largely affects postoperative kinematic results particularly during flexion.

Entities:  

Keywords:  Total knee arthroplasty (TKA); femoral component rotational alignment; navigation

Year:  2016        PMID: 26855940      PMCID: PMC4716940          DOI: 10.3978/j.issn.2305-5839.2015.12.66

Source DB:  PubMed          Journal:  Ann Transl Med        ISSN: 2305-5839


  15 in total

1.  The Ranawat Award. Femoral component rotation during total knee arthroplasty.

Authors:  C W Olcott; R D Scott
Journal:  Clin Orthop Relat Res       Date:  1999-10       Impact factor: 4.176

2.  Rotational malalignment of the femoral component in total knee arthroplasty.

Authors:  T K Fehring
Journal:  Clin Orthop Relat Res       Date:  2000-11       Impact factor: 4.176

3.  Anatomic rotational relationships of the proximal tibia, distal femur, and patella: implications for rotational alignment in total knee arthroplasty.

Authors:  Stephen J Incavo; Kathryn M Coughlin; Charles Pappas; Bruce D Beynnon
Journal:  J Arthroplasty       Date:  2003-08       Impact factor: 4.757

4.  Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement.

Authors:  Jean-Yves Jenny; Cyril Boeri
Journal:  Acta Orthop Scand       Date:  2004-02

5.  What should the surgeon aim for when performing computer-assisted total knee arthroplasty?

Authors:  Geert Van Damme; Koen Defoort; Yves Ducoulombier; Francis Van Glabbeek; Johan Bellemans; Jan Victor
Journal:  J Bone Joint Surg Am       Date:  2005       Impact factor: 5.284

6.  The variability of femoral rotational alignment in total knee arthroplasty.

Authors:  Robert A Siston; Jay J Patel; Stuart B Goodman; Scott L Delp; Nicholas J Giori
Journal:  J Bone Joint Surg Am       Date:  2005-10       Impact factor: 5.284

7.  Flexion space configuration in total knee arthroplasty.

Authors:  R S Laskin
Journal:  J Arthroplasty       Date:  1995-10       Impact factor: 4.757

8.  Effect of rotational alignment on patellar tracking in total knee arthroplasty.

Authors:  M Akagi; Y Matsusue; T Mata; Y Asada; M Horiguchi; H Iida; T Nakamura
Journal:  Clin Orthop Relat Res       Date:  1999-09       Impact factor: 4.176

9.  The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens.

Authors:  Y S Anouchi; L A Whiteside; A D Kaiser; M T Milliano
Journal:  Clin Orthop Relat Res       Date:  1993-02       Impact factor: 4.176

10.  How precise is the determination of rotational alignment of the femoral prosthesis in total knee arthroplasty: an in vivo study.

Authors:  W P Yau; K Y Chiu; W M Tang
Journal:  J Arthroplasty       Date:  2007-10       Impact factor: 4.757

View more
  7 in total

1.  Proven accuracy for a new dynamic gap measurement in navigated TKA.

Authors:  Volkmar Mehliß; Marco Strauch Leira; Agustín Serrano Olaizola; Wolfgang Scior; Heiko Graichen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-05-22       Impact factor: 4.342

2.  Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation.

Authors:  Soheil Mehdipour; Mohamad Qoreishi; Ali Keipourfard
Journal:  Arch Bone Jt Surg       Date:  2020-09

3.  Finite element analysis of the tibial component alignment in a transverse plane in total knee arthroplasty.

Authors:  Roman Popescu; Stefan Cristea; Valentin Oleksik; Adrian Marius Pascu; Emil George Haritinian
Journal:  J Appl Biomed       Date:  2021-09-20       Impact factor: 1.797

4.  No correlation between rotation of femoral components in the transverse plane and clinical outcome after total knee arthroplasty.

Authors:  Roland Becker; Katharina Bäker; Hagen Hommel; Manfred Bernard; Sebastian Kopf
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-05-16       Impact factor: 4.342

5.  [Gait analysis after total knee arthroplasty assisted by three-dimensional printing navigation template].

Authors:  Maolin Sun; Liu Yang; Rui He; Guangxing Chen; Lin Guo; Xiaojun Duan; Ying Zhang; Jiawei Sun; Huaquan Fan
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2019-08-15

6.  A computer-assisted, tibia-first technique for improved femoral component rotation in total knee arthroplasty.

Authors:  Chong Meng Lee; Malkit K Dhillon; Mohd Amin Sulaiman
Journal:  Arthroplast Today       Date:  2017-08-18

7.  Spacer-based gap balancing is useful in total knee arthroplasty: a 3-year follow-up of a retrospective study.

Authors:  Yanhui Hu; Da Song; Yi Liu; Yong Zhao; Wenpu Ma; Yiqun Yang; Zhenfeng Yuan
Journal:  J Orthop Surg Res       Date:  2021-10-21       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.