Literature DB >> 33088865

Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation.

Soheil Mehdipour1, Mohamad Qoreishi2, Ali Keipourfard1.   

Abstract

BACKGROUND: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase the accuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies are controversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-based PS (patient specific)-guided TKA were compared to the results of conventional instrumentation (CVI) TKA. The guides were designed on the basis of distal femoral and proximal tibial pin orientation of the conventional related guides.
METHODS: The present study was carried out on 24 TKA candidates randomly assigned to two PSI (n=12) and CVI (n=12) groups. The patients were postoperatively followed for 2 years. Then, the hip-knee-ankle angle (HKAA), femoral component flexion, and orientation of components in the coronal plane were measured. In addition, the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) Index and Knee Society Score (KSS) questionnaire were completed for all the patients.
RESULTS: The rate of the outliers of the HKAA was higher in the CVI group (41.7% and 8.3%; P=0.077); nevertheless, the difference was not significant in this regard. The rate of the outliers of other radiographic measurements and operational time were similar in both groups. Furthermore, there was no significant difference between the two groups in terms of the WOMAC and KSS.
CONCLUSION: The CT-based PS-guided TKA may result in the improved postoperative mechanical alignment of the limb and should be considered in complicated TKAs. However, future studies should investigate whether the results of PSI TKA support the considerably higher costs of this technique. 2020 © BY THE ARCHIVES OF BONE AND JOINT SURGERY.

Entities:  

Keywords:  Mechanical alignment; Patient-specific instrumentation; Total knee arthroplasty

Year:  2020        PMID: 33088865      PMCID: PMC7547163          DOI: 10.22038/abjs.2020.41571.2124

Source DB:  PubMed          Journal:  Arch Bone Jt Surg        ISSN: 2345-461X


  27 in total

Review 1.  Shorter survival rate in varus-aligned knees after total knee arthroplasty.

Authors:  Hai-Xiao Liu; Ping Shang; Xiao-Zhou Ying; Yu Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-09-16       Impact factor: 4.342

2.  Patient-Specific Cutting Guides Were Not Better Than Conventional Instrumentation for Total Knee Arthroplasty.

Authors:  William M Mihalko
Journal:  J Bone Joint Surg Am       Date:  2015-11-18       Impact factor: 5.284

3.  Functional Outcome and Quality of Life after Patient-Specific Instrumentation in Total Knee Arthroplasty.

Authors:  Jerry Yongqiang Chen; Pak Lin Chin; Darren Keng Jin Tay; Shi-Lu Chia; Ngai Nung Lo; Seng Jin Yeo
Journal:  J Arthroplasty       Date:  2015-04-11       Impact factor: 4.757

Review 4.  No demonstrable benefit for coronal alignment outcomes in PSI knee arthroplasty: A systematic review and meta-analysis.

Authors:  A Mannan; T O Smith; C Sagar; N J London; P J A Molitor
Journal:  Orthop Traumatol Surg Res       Date:  2015-03-20       Impact factor: 2.256

5.  The effect of alignment and BMI on failure of total knee replacement.

Authors:  Merrill A Ritter; Kenneth E Davis; John B Meding; Jeffery L Pierson; Michael E Berend; Robert A Malinzak
Journal:  J Bone Joint Surg Am       Date:  2011-09-07       Impact factor: 5.284

6.  Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA.

Authors:  Werner Anderl; Leo Pauzenberger; Roman Kölblinger; Gabriele Kiesselbach; Georg Brandl; Brenda Laky; Bernhard Kriegleder; Philipp Heuberer; Eva Schwameis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-19       Impact factor: 4.342

7.  A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement.

Authors:  K Chareancholvanich; R Narkbunnam; C Pornrattanamaneewong
Journal:  Bone Joint J       Date:  2013-03       Impact factor: 5.082

8.  Patient-specific total knee arthroplasty required frequent surgeon-directed changes.

Authors:  Benjamin M Stronach; Christopher E Pelt; Jill Erickson; Christopher L Peters
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

9.  Patient-specific instrumentation in total knee arthroplasty: simpler, faster and more accurate than standard instrumentation-a randomized controlled trial.

Authors:  João Vide; Tânia Pinto Freitas; Acácio Ramos; Henrique Cruz; João Paulo Sousa
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-19       Impact factor: 4.342

Review 10.  What is the optimal alignment of the tibial and femoral components in knee arthroplasty?

Authors:  Kirill Gromov; Mounim Korchi; Morten G Thomsen; Henrik Husted; Anders Troelsen
Journal:  Acta Orthop       Date:  2014-07-18       Impact factor: 3.717

View more
  3 in total

Review 1.  Involvement of NF-κB/NLRP3 axis in the progression of aseptic loosening of total joint arthroplasties: a review of molecular mechanisms.

Authors:  Mohamad Qoreishi; Meysam Panahi; Omyd Dorodi; Naser Ghanbari; Saman Shakeri Jousheghan
Journal:  Naunyn Schmiedebergs Arch Pharmacol       Date:  2022-04-04       Impact factor: 3.000

Review 2.  Anterior femoral notching ≥ 3 mm is associated with increased risk for supracondylar periprosthetic femoral fracture after total knee arthroplasty: a systematic review and meta-analysis.

Authors:  Dimitrios Stamiris; Nifon K Gkekas; Konstantinos Asteriadis; Stavros Stamiris; Panagiotis Anagnostis; Lazaros Poultsides; Ioannis Sarris; Michael Potoupnis; Eustathios Kenanidis; Eleftherios Tsiridis
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-04-26

3.  Functional outcomes in patient specific instrumentation vs. conventional instrumentation for total knee arthroplasty; a systematic review and meta-analysis of prospective studies.

Authors:  Branavan Rudran; Henry Magill; Nikhil Ponugoti; Andy Williams; Simon Ball
Journal:  BMC Musculoskelet Disord       Date:  2022-07-23       Impact factor: 2.562

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.