Literature DB >> 11064975

Rotational malalignment of the femoral component in total knee arthroplasty.

T K Fehring1.   

Abstract

Ligamentous balancing is a crucial part of total knee arthroplasty. To ensure proper kinematics, balance must be achieved in flexion and extension. Failure to do so may result in limited range of motion, premature polyethylene wear, or patellofemoral tracking problems. Balancing in extension is dependent on the type and extent of correctional ligamentous release. Flexion balance is dependent on proper femoral rotation. There are two methods to determine femoral rotation. In the classic method, the knee is tensed in flexion after ligamentous release in extension. The anteroposterior cut then is made parallel to the cut tibial surface. Alternatively, the anteroposterior cut can be based off fixed femoral landmarks. The purpose of the current study was to determine the variance between balancing the flexion gap with the classic method versus the technique of using fixed femoral landmarks to determine rotation. One hundred consecutive posterior stabilized knee arthroplasties were performed using the classic method. The resected posterior condyles in each case were measured. The actual difference between the resected condyles using the classic method was compared with the calculated difference of resected bone using bony landmarks to determine rotation. A variance analysis then was performed. Compared with classically balanced knees, rotational errors of at least 3 degrees occurred in 45 % of patients when rotation was determined from fixed bony landmarks. These patients had trapezoidal rather than rectangular flexion gaps. Such errors may have implications regarding polyethylene wear, range of motion, and long-term clinical results.

Entities:  

Mesh:

Year:  2000        PMID: 11064975     DOI: 10.1097/00003086-200011000-00010

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  63 in total

1.  Soft tissue balance using the tibia first gap technique with navigation system in cruciate-retaining total knee arthroplasty.

Authors:  Tomoyuki Matsumoto; Hirotsugu Muratsu; Seiji Kubo; Takehiko Matsushita; Kazunari Ishida; Hirosi Sasaki; Shinya Oka; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Int Orthop       Date:  2011-10-27       Impact factor: 3.075

2.  Comparison of the tibiofemoral rotational alignment after mobile and fixed bearing total knee arthroplasty.

Authors:  Dongwook Kim; Sang Cheol Seong; Myung Chul Lee; Sahnghoon Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-06       Impact factor: 4.342

3.  CT measurements prior to computer-assisted total knee arthroplasty do not improve rotational placement of the femoral component.

Authors:  A de Ladoucette
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12       Impact factor: 4.342

4.  [Soft tissue balanced navigation of total knee arthroplasties].

Authors:  C Schnurr; I Stolzenberg; J Nessler; P Eysel; P König
Journal:  Oper Orthop Traumatol       Date:  2012-04       Impact factor: 1.154

5.  Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA.

Authors:  Eun-Kyoo Song; Jong-Keun Seon; Ji-Hyeon Yim; Nathan A Netravali; William L Bargar
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

6.  Soft tissue balance measurement in minimal incision surgery compared to conventional total knee arthroplasty.

Authors:  Tomoyuki Matsumoto; Hirotsugu Muratsu; Seiji Kubo; Kiyonori Mizuno; Keisuke Kinoshita; Kazunari Ishida; Takehiko Matsushita; Ken Sasaki; Katsumasa Tei; Koji Takayama; Hiroshi Sasaki; Shinya Oka; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-03       Impact factor: 4.342

7.  Femoral component rotation in patients with leg axis deviation.

Authors:  Tim Classen; Stefan Landgraeber; Alexander Wegner; Ralf-Dietrich Müller; Marius von Knoch
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-12-15       Impact factor: 4.342

Review 8.  Rotational alignment of the femoral component in total knee arthroplasty.

Authors:  Claudio Carlo Castelli; Daniele Antonio Falvo; Mario Luigi Iapicca; Valerio Gotti
Journal:  Ann Transl Med       Date:  2016-01

9.  Is referencing the posterior condyles sufficient to achieve a rectangular flexion gap in total knee arthroplasty?

Authors:  Christoph Schnurr; Jochen Nessler; Dietmar Pierre König
Journal:  Int Orthop       Date:  2008-10-28       Impact factor: 3.075

10.  How to improve femoral component rotational alignment in computer-assisted TKA.

Authors:  F Zambianchi; T Luyckx; J Victor; V Digennaro; A Giorgini; F Catani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-10       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.