Literature DB >> 26835101

Management of Cardiovascular Implantable Electronic Devices Infections in High-Risk Patients.

Charles Kennergren1.   

Abstract

The incidence of infection following implantation of cardiovascular implantable electronic devices (CIEDs) is increasing, as is the number of pulse generator replacements and upgrades. The rate of infections is rising faster than the rate of device implantation, mainly due to the increasing age and number of comorbidities of patients receiving the devices. Patients with a CIED infection usually require hospitalisation, multiple consultations, prolonged intravenous antibiotics and, in the majority of cases, CIED explantation and replacement. A significant proportion die of their infection. CIED infection therefore represents a substantial health and economic burden, and management of infections is critical. Numerous risk factors have been identified including host, procedure and device-related factors. Established strategies for preventing CIED infections include intravenous antibiotics and aseptic techniques. The TYRX™ Absorbable Antibacterial Envelope offers potential as an effective method to reduce CIED infections. Several studies have found a statistically significant association between antibacterial envelope use and reduced incidence of CIED infection in high-risk patients. A prospective, randomised trial to further evaluate this potentially important strategy for CIED infection prophylaxis is underway.

Entities:  

Keywords:  Cardiovascular implantable electronic device infections; antibacterial envelope; cardiac resynchronisation; implantable cardioverter-defibrillators

Year:  2015        PMID: 26835101      PMCID: PMC4711570          DOI: 10.15420/aer.2015.4.1.53

Source DB:  PubMed          Journal:  Arrhythm Electrophysiol Rev        ISSN: 2050-3369


  51 in total

1.  Recurrent implantable cardioverter-defibrillator replacement is associated with an increasing risk of pocket-related complications.

Authors:  C Jan Willem Borleffs; Joep Thijssen; Mihály K de Bie; Johannes B van Rees; Guido H van Welsenes; Lieselot van Erven; Jeroen J Bax; Suzanne C Cannegieter; Martin J Schalij
Journal:  Pacing Clin Electrophysiol       Date:  2010-04-27       Impact factor: 1.976

2.  Complications associated with implantable cardioverter-defibrillator replacement in response to device advisories.

Authors:  Paul A Gould; Andrew D Krahn
Journal:  JAMA       Date:  2006-04-26       Impact factor: 56.272

3.  Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA).

Authors:  Bruce L Wilkoff; Charles J Love; Charles L Byrd; Maria Grazia Bongiorni; Roger G Carrillo; George H Crossley; Laurence M Epstein; Richard A Friedman; Charles E H Kennergren; Przemyslaw Mitkowski; Raymond H M Schaerf; Oussama M Wazni
Journal:  Heart Rhythm       Date:  2009-05-22       Impact factor: 6.343

4.  Nonstaphylococcal infections of cardiac implantable electronic devices.

Authors:  George M Viola; Leah L Awan; Rabih O Darouiche
Journal:  Circulation       Date:  2010-05-03       Impact factor: 29.690

5.  16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008.

Authors:  Arnold J Greenspon; Jasmine D Patel; Edmund Lau; Jorge A Ochoa; Daniel R Frisch; Reginald T Ho; Behzad B Pavri; Steven M Kurtz
Journal:  J Am Coll Cardiol       Date:  2011-08-30       Impact factor: 24.094

6.  Diagnosis and management of infections involving implantable electrophysiologic cardiac devices.

Authors:  J D Chua; B L Wilkoff; I Lee; N Juratli; D L Longworth; S M Gordon
Journal:  Ann Intern Med       Date:  2000-10-17       Impact factor: 25.391

7.  Management and outcome of permanent pacemaker and implantable cardioverter-defibrillator infections.

Authors:  Muhammad R Sohail; Daniel Z Uslan; Akbar H Khan; Paul A Friedman; David L Hayes; Walter R Wilson; James M Steckelberg; Sarah Stoner; Larry M Baddour
Journal:  J Am Coll Cardiol       Date:  2007-04-23       Impact factor: 24.094

8.  Prevalence of bacterial colonization of generator pockets in implantable cardioverter defibrillator patients without signs of infection undergoing generator replacement or lead revision.

Authors:  Thomas Kleemann; Torsten Becker; Margit Strauss; Ngoc Dyck; Udo Weisse; Werner Saggau; Ulrich Burkhardt; Karlheinz Seidl
Journal:  Europace       Date:  2010-01       Impact factor: 5.214

9.  Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association.

Authors:  Larry M Baddour; Andrew E Epstein; Christopher C Erickson; Bradley P Knight; Matthew E Levison; Peter B Lockhart; Frederick A Masoudi; Eric J Okum; Walter R Wilson; Lee B Beerman; Ann F Bolger; N A Mark Estes; Michael Gewitz; Jane W Newburger; Eleanor B Schron; Kathryn A Taubert
Journal:  Circulation       Date:  2010-01-04       Impact factor: 29.690

10.  Risk factors for mortality in patients with cardiac device-related infection.

Authors:  Timir S Baman; Sanjaya K Gupta; Javier A Valle; Elina Yamada
Journal:  Circ Arrhythm Electrophysiol       Date:  2009-02-13
View more
  1 in total

1.  Single-Chamber Leadless Cardiac Pacemaker in Patients Without Atrial Fibrillation: Findings From Campania Leadless Registry.

Authors:  Vincenzo Russo; Antonello D'Andrea; Stefano De Vivo; Anna Rago; Gianluca Manzo; Antonio Bocchetti; Andrea Antonio Papa; Valerio Giordano; Ernesto Ammendola; Berardo Sarubbi; Paolo Golino; Antonio D'Onofrio; Gerardo Nigro
Journal:  Front Cardiovasc Med       Date:  2022-01-14
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.