Literature DB >> 19808457

Risk factors for mortality in patients with cardiac device-related infection.

Timir S Baman1, Sanjaya K Gupta, Javier A Valle, Elina Yamada.   

Abstract

BACKGROUND: Because of the increased use of pacemakers and implantable cardioverter defibrillators, infection has become a complication with significant morbidity and mortality. Data on risk factors for mortality in patients with cardiac-device related infection are limited. We evaluated the prognostic significance of key clinical and echocardiographic variables in a large retrospective population of patients with cardiac-device related infection. METHODS AND
RESULTS: Two hundred ten patients with cardiac-device related infection were identified at the University of Michigan between 1995 and 2006. Data were abstracted on key clinical and echocardiographic variables, treatment strategy, and 6-month outcomes. We used multivariable Cox proportional hazards models to examine clinical and echocardiographic variables that were associated with 6-month mortality. Mean age for our study population was 63+/-17 years, and 72 (44%) were women. All-cause 6-month mortality was 18% (n=37). Independent variables associated with death were systemic embolization (hazard ratio 7.11; 95% CI 2.74 to 18.48), moderate or severe tricuspid regurgitation (hazard ratio 4.24; 95% CI 1.84 to 9.75), abnormal right ventricular function (hazard ratio 3.59; 95% CI 1.57 to 8.24), and abnormal renal function (hazard ratio 2.98; 95% CI 1.17 to 7.59). Size and mobility of cardiac device vegetations were not independently associated with mortality.
CONCLUSIONS: We identified several clinical and echocardiographic variables that identify patients with cardiac-device related infection who are at high-risk for mortality and may benefit from more aggressive evaluation.

Entities:  

Mesh:

Year:  2009        PMID: 19808457     DOI: 10.1161/CIRCEP.108.816868

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  27 in total

1.  Cardiac implantable electronic devices in end-stage renal disease patients: preservation of central venous circulation.

Authors:  Gustavo Lopera; Gerald A Beathard; Jose Exaire; Roger Carrillo
Journal:  J Interv Card Electrophysiol       Date:  2012-06       Impact factor: 1.900

2.  The prevalence of methicillin resistant organisms among pacemaker and defibrillator implant recipients.

Authors:  David J Rodriguez; Aisha Afzal; Rudolph Evonich; David E Haines
Journal:  Am J Cardiovasc Dis       Date:  2012-05-15

Review 3.  18F-FDG-PET/CT Imaging to Diagnose Septic Emboli and Mycotic Aneurysms in Patients with Endocarditis and Cardiac Device Infections.

Authors:  Nidaa Mikail; Khadija Benali; Besma Mahida; Jonathan Vigne; Fabien Hyafil; François Rouzet; Dominique Le Guludec
Journal:  Curr Cardiol Rep       Date:  2018-03-06       Impact factor: 2.931

4.  Cardiovascular implantable device infections.

Authors:  George M Viola; Rabih O Darouiche
Journal:  Curr Infect Dis Rep       Date:  2011-08       Impact factor: 3.725

5.  Real-world effectiveness of infection prevention interventions for reducing procedure-related cardiac device infections: Insights from the veterans affairs clinical assessment reporting and tracking program.

Authors:  Archana Asundi; Maggie Stanislawski; Payal Mehta; Anna E Baron; Hillary J Mull; P Michael Ho; Peter J Zimetbaum; Kalpana Gupta; Westyn Branch-Elliman
Journal:  Infect Control Hosp Epidemiol       Date:  2019-06-04       Impact factor: 3.254

Review 6.  Accuracy of Positron Emission Tomography as a Diagnostic Tool for Lead Endocarditis: Design of the Prospective Multicentre ENDOTEP Study.

Authors:  Sana Amraoui; Ghoufrane Tlili; Elif Hindié; Paul Perez; Olivia Peuchant; Laurence Bordenave; Pierre Bordachar
Journal:  Eur Cardiol       Date:  2016-08

Review 7.  A Roadmap for Reducing Cardiac Device Infections: a Review of Epidemiology, Pathogenesis, and Actionable Risk Factors to Guide the Development of an Infection Prevention Program for the Electrophysiology Laboratory.

Authors:  Westyn Branch-Elliman
Journal:  Curr Infect Dis Rep       Date:  2017-08-16       Impact factor: 3.725

8.  Implementation of Infection Prevention and Antimicrobial Stewardship in Cardiac Electrophysiology Laboratories: Results from the SHEA Research Network.

Authors:  Preeti Mehrotra; Kalpana Gupta; Judith Strymish; Daniel B Kramer; Anne Lambert-Kerzner; P Michael Ho; Westyn Branch-Elliman
Journal:  Infect Control Hosp Epidemiol       Date:  2017-01-20       Impact factor: 3.254

9.  New Insights into Predictors of Cardiac Implantable Electronic Device Infection.

Authors:  Hossein Sadeghi; Abolfath Alizadehdiz; Amirfarjam Fazelifar; Zahra Emkanjoo; Majid Haghjoo
Journal:  Tex Heart Inst J       Date:  2018-06-01

10.  Cardiac implantable electronic device infections: facts, current practice, and the unanswered questions.

Authors:  Khaldoun G Tarakji; Bruce L Wilkoff
Journal:  Curr Infect Dis Rep       Date:  2014-09       Impact factor: 3.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.