Literature DB >> 20439783

Nonstaphylococcal infections of cardiac implantable electronic devices.

George M Viola1, Leah L Awan, Rabih O Darouiche.   

Abstract

BACKGROUND: Along with the rising use of cardiac implantable electronic devices (CIEDs), there has been a disproportional increase in the number of infections of such devices. Little is known about nonstaphylococcal CIED-related infections, which make up approximately 10% to 30% of all CIED infections. METHODS AND
RESULTS: A retrospective review of hospital records of patients admitted with a CIED-related infection was conducted in 4 academic hospitals in Houston, Tex, between 2002 and 2009. Of the 504 identified patients with CIED-related infection, 80 (16%) had a nonstaphylococcal infection and were the focus of this study. The mean duration of CIED placement before infection was 109+/-27 weeks, whereas 44% had their device previously manipulated within a mean of 29.5+/-6 weeks. The mean duration of clinical symptoms before admission was 48+/-12.8 days. Furthermore, 13 patients (16%) presented with CIED-related endocarditis. Although not described in prior reports, we identified 3 definite and 2 suspected cases of secondary Gram-negative bacteria seeding of the CIED. Inappropriate antimicrobial coverage was provided in approximately 50% of the cases with a mean period of 2.1 days. The overall mortality rate was 4%.
CONCLUSIONS: Nonstaphylococcal CIED-related infections are prevalent and diverse with a relatively low virulence and mortality rate. Because nonstaphylococcal organisms are capable of secondarily seeding the CIED, a high suspicion for CIED-related infection is warranted in patients with bloodstream infection. In patients with suspected CIED infection, adequate Gram-positive and Gram-negative antibacterial coverage should be administered until microbiological data become available.

Entities:  

Mesh:

Year:  2010        PMID: 20439783     DOI: 10.1161/CIRCULATIONAHA.110.936708

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  18 in total

1.  Cardiovascular implantable device infections.

Authors:  George M Viola; Rabih O Darouiche
Journal:  Curr Infect Dis Rep       Date:  2011-08       Impact factor: 3.725

2.  The Diagnosis and Treatment of Pacemaker-Associated Infection.

Authors:  Michael Döring; Sergio Richter; Gerhard Hindricks
Journal:  Dtsch Arztebl Int       Date:  2018-06-29       Impact factor: 5.594

Review 3.  [Hypersensitivity reactions to implantable cardiac pacemakers and defibrillators].

Authors:  B Kreft
Journal:  Hautarzt       Date:  2016-05       Impact factor: 0.751

4.  Pacemaker lead endocarditis due to multidrug-resistant Corynebacterium striatum detected with sonication of the device.

Authors:  Alessandra Oliva; Valeria Belvisi; Marco Iannetta; Carolina Andreoni; Maria T Mascellino; Miriam Lichtner; Vincenzo Vullo; Claudio M Mastroianni
Journal:  J Clin Microbiol       Date:  2010-10-13       Impact factor: 5.948

5.  Permanent pacemaker-associated actinomycetemcomitans endocarditis: A case report.

Authors:  Zhenhong Li; Jennifer Madeo; Shadab Ahmed; Alex Vidal; Amgad Makaryus; Jose Mejia; Tabassum Yasmin
Journal:  Germs       Date:  2013-09-01

6.  [Device related infections. How to identify and how to treat].

Authors:  Christoph Stellbrink; Bert Hansky
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-09

7.  Management of Cardiovascular Implantable Electronic Devices Infections in High-Risk Patients.

Authors:  Charles Kennergren
Journal:  Arrhythm Electrophysiol Rev       Date:  2015-04-10

8.  Sonication of explanted cardiac implants improves microbial detection in cardiac device infections.

Authors:  Alessandra Oliva; Bich Lien Nguyen; Maria T Mascellino; Alessandra D'Abramo; Marco Iannetta; Antonio Ciccaglioni; Vincenzo Vullo; Claudio M Mastroianni
Journal:  J Clin Microbiol       Date:  2012-11-28       Impact factor: 5.948

9.  Epidemiology of cardiac implantable electronic device infections: incidence and risk factors.

Authors:  Hui-Chen Han; Nathaniel M Hawkins; Charles M Pearman; David H Birnie; Andrew D Krahn
Journal:  Europace       Date:  2021-06-23       Impact factor: 5.214

10.  Influence of the type of pathogen on the clinical course of infectious complications related to cardiac implantable electronic devices.

Authors:  Anna Polewczyk; Wojciech Jacheć; Luca Segreti; Maria Grazia Bongiorni; Andrzej Kutarski
Journal:  Sci Rep       Date:  2021-07-21       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.