Abstract

Novel technologies have been developed recently to assess contact between the ablation catheter and the underlying tissue in an attempt to improve safe and effective lesion delivery. The most recently developed technology is the SmartTouch™ catheter which is an open irrigated-tip catheter integrated within the CARTO 3 3D mapping system. In this review we consider the role of contact force technology, evaluate the published data and discuss the potential applications of this novel technology.

Keywords:  Ablation catheter; CARTO 3 3D mapping system; SmartTouch™; lesion delivery

Year:  2012        PMID: 26835032      PMCID: PMC4711500          DOI: 10.15420/aer.2012.1.59

Source DB:  PubMed          Journal:  Arrhythm Electrophysiol Rev        ISSN: 2050-3369


  10 in total

1.  Effect of respiration on catheter-tissue contact force during ablation of atrial arrhythmias.

Authors:  Saurabh Kumar; Joseph B Morton; Karen Halloran; Steven J Spence; Geoffrey Lee; Michael C G Wong; Peter M Kistler; Jonathan M Kalman
Journal:  Heart Rhythm       Date:  2012-02-14       Impact factor: 6.343

2.  Cryoablation versus radiofrequency energy for the ablation of atrioventricular nodal reentrant tachycardia (the CYRANO Study): results from a large multicenter prospective randomized trial.

Authors:  Isabel Deisenhofer; Bernhard Zrenner; Yue-Hui Yin; Heinz-Friedrich Pitschner; Malte Kuniss; Georg Grossmann; Sascha Stiller; Armin Luik; Christian Veltmann; Julia Frank; Julia Linner; Heidi L Estner; Andreas Pflaumer; Jinjin Wu; Christian von Bary; Ekrem Ucer; Tilko Reents; Stylianos Tzeis; Stephanie Fichtner; Susanne Kathan; Martin R Karch; Clemens Jilek; Sonia Ammar; Christof Kolb; Zeng-Chang Liu; Bernhard Haller; Claus Schmitt; Gabriele Hessling
Journal:  Circulation       Date:  2010-11-15       Impact factor: 29.690

3.  Radiofrequency catheter ablation of accessory pathways. Outcome and use of antiarrhythmic drugs during follow-up.

Authors:  N Dagres; J R Clague; H Kottkamp; G Hindricks; G Breithardt; M Borggrefe
Journal:  Eur Heart J       Date:  1999-12       Impact factor: 29.983

4.  Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation.

Authors:  Riccardo Cappato; Hugh Calkins; Shih-Ann Chen; Wyn Davies; Yoshito Iesaka; Jonathan Kalman; You-Ho Kim; George Klein; Andrea Natale; Douglas Packer; Allan Skanes; Federico Ambrogi; Elia Biganzoli
Journal:  Circ Arrhythm Electrophysiol       Date:  2009-12-07

5.  A novel radiofrequency ablation catheter using contact force sensing: Toccata study.

Authors:  Karl-Heinz Kuck; Vivek Y Reddy; Boris Schmidt; Andrea Natale; Petr Neuzil; Nadir Saoudi; Josef Kautzner; Claudia Herrera; Gerhard Hindricks; Pierre Jaïs; Hiroshi Nakagawa; Hendrik Lambert; Dipen C Shah
Journal:  Heart Rhythm       Date:  2011-08-26       Impact factor: 6.343

6.  Assessment of catheter tip contact force resulting in cardiac perforation in swine atria using force sensing technology.

Authors:  Francesco Perna; E Kevin Heist; Stephan B Danik; Conor D Barrett; Jeremy N Ruskin; Moussa Mansour
Journal:  Circ Arrhythm Electrophysiol       Date:  2011-01-19

7.  Peri-mitral atrial flutter in patients with atrial fibrillation ablation.

Authors:  Seiichiro Matsuo; Matthew Wright; Sébastien Knecht; Isabelle Nault; Nicolas Lellouche; Kang-Teng Lim; Leonardo Arantes; Mark D O'Neill; Mélèze Hocini; Pierre Jaïs; Michel Haïssaguerre
Journal:  Heart Rhythm       Date:  2009-10-06       Impact factor: 6.343

8.  Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus.

Authors:  Katsuaki Yokoyama; Hiroshi Nakagawa; Dipen C Shah; Hendrik Lambert; Giovanni Leo; Nicolas Aeby; Atsushi Ikeda; Jan V Pitha; Tushar Sharma; Ralph Lazzara; Warren M Jackman
Journal:  Circ Arrhythm Electrophysiol       Date:  2008-12-02

9.  Clinical impact of an open-irrigated radiofrequency catheter with direct force measurement on atrial fibrillation ablation.

Authors:  Martin Martinek; Christine Lemes; Elisabeth Sigmund; Michael Derndorfer; Josef Aichinger; Siegmund Winter; Hans-Joachim Nesser; Helmut Pürerfellner
Journal:  Pacing Clin Electrophysiol       Date:  2012-09-04       Impact factor: 1.976

10.  Catheter ablation of stable ventricular tachycardia before defibrillator implantation in patients with coronary heart disease (VTACH): a multicentre randomised controlled trial.

Authors:  Karl-Heinz Kuck; Anselm Schaumann; Lars Eckardt; Stephan Willems; Rodolfo Ventura; Etienne Delacrétaz; Heinz-Friedrich Pitschner; Josef Kautzner; Burghard Schumacher; Peter S Hansen
Journal:  Lancet       Date:  2010-01-02       Impact factor: 79.321

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.