Literature DB >> 26811035

Kinematically aligned TKA can align knee joint line to horizontal.

Hyung-Min Ji1, Jun Han1, Dong San Jin1, Hyunseok Seo1, Ye-Yeon Won2.   

Abstract

PURPOSE: The joint line of the native knee is horizontal to the floor and perpendicular to the vertical weight-bearing axis of the patient in a bipedal stance. The purposes of this study were as follows: (1) to find out the distribution of the native joint line in a population of normal patients with normal knees; (2) to compare the native joint line orientation between patients receiving conventional mechanically aligned total knee arthroplasty (TKA), navigated mechanically aligned TKA, and kinematically aligned TKA; and (3) to determine which of the three TKA methods aligns the postoperative knee joint perpendicular to the weight-bearing axis of the limb in bipedal stance.
METHODS: To determine the joint line orientation of a native knee, 50 full-length standing hip-to-ankle digital radiographs were obtained in 50 young, healthy individuals. The angle between knee joint line and the line parallel to the floor was measured and defined as joint line orientation angle (JLOA). JLOA was also measured prior to and after conventional mechanically aligned TKA (65 knees), mechanically aligned TKA using imageless navigation (65 knees), and kinematically aligned TKA (65 knees). The proportion of the knees similar to the native joint line was calculated for each group.
RESULTS: The mean JLOA in healthy individuals was parallel to the floor (0.2° ± 1.1°). The pre-operative JLOA of all treatment groups slanted down to the lateral side. Postoperative JLOA slanted down to the lateral side in conventional mechanically aligned TKA (-3.3° ± 2.2°) and in navigation mechanically aligned TKA (-2.6° ± 1.8°), while it was horizontal to the floor in kinematically aligned TKA (0.6° ± 1.7°). Only 6.9 % of the conventional mechanically aligned TKA and 16.9 % of the navigation mechanically aligned TKA were within one SD of the mean JLOA of the native knee, while the proportion was significantly higher (50.8 %) in kinematically aligned TKA. The portion was statistically greater in mechanically aligned TKA group than the other two.
CONCLUSION: Postoperative joint line orientation after kinematically aligned TKA was more similar to that of native knees than that of mechanically aligned TKA and horizontal to the floor. Kinematically aligned TKA can restore pre-arthritic knee joint line orientation, while mechanically aligned TKA is inefficient in achieving the purpose even if navigation TKA is employed. LEVEL OF EVIDENCE: III.

Entities:  

Keywords:  Alignment; Arthroplasty; Humans; Knee joint; Replacement

Mesh:

Year:  2016        PMID: 26811035     DOI: 10.1007/s00167-016-3995-3

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  27 in total

1.  The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty.

Authors:  Xiaojun Shi; Bin Shen; Pengde Kang; Jing Yang; Zongke Zhou; Fuxing Pei
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-02       Impact factor: 4.342

2.  The effect of valgus/varus malalignment on load distribution in total knee replacements.

Authors:  Frederick W Werner; David C Ayers; Lorin P Maletsky; Paul J Rullkoetter
Journal:  J Biomech       Date:  2005-02       Impact factor: 2.712

3.  Retrieval analysis of posterior stabilized polyethylene tibial inserts and its clinical relevance.

Authors:  Hee-Nee Pang; Paul Jamieson; Matthew G Teeter; Richard W McCalden; Douglas D R Naudie; Steven J MacDonald
Journal:  J Arthroplasty       Date:  2013-07-01       Impact factor: 4.757

4.  Functional joint line obliquity after kinematic total knee arthroplasty.

Authors:  Jonathan Hutt; Vincent Massé; Martin Lavigne; Pascal-André Vendittoli
Journal:  Int Orthop       Date:  2015-03-21       Impact factor: 3.075

5.  Tibiofemoral alignment in posterior stabilized total knee arthroplasty: Static alignment does not predict dynamic tibial plateau loading.

Authors:  Emily J Miller; Mark W Pagnano; Kenton R Kaufman
Journal:  J Orthop Res       Date:  2014-05-12       Impact factor: 3.494

6.  Neutral mechanical alignment: a requirement for successful TKA: opposes.

Authors:  Johan Bellemans
Journal:  Orthopedics       Date:  2011-09-09       Impact factor: 1.390

7.  Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement.

Authors:  Georg Matziolis; Joern Adam; Carsten Perka
Journal:  Arch Orthop Trauma Surg       Date:  2010-02-18       Impact factor: 3.067

8.  Quantification of soft tissue balance in total knee arthroplasty using finite element analysis.

Authors:  Kwang-Jun Oh; Won Man Park; Kyungsoo Kim; Yoon Hyuk Kim
Journal:  Comput Methods Biomech Biomed Engin       Date:  2013-03-12       Impact factor: 1.763

9.  Impact of the tibial slope on range of motion after low-contact-stress, mobile-bearing, total knee arthroplasty.

Authors:  Norbert Kastner; Simon Sternbauer; Jörg Friesenbichler; Ines Vielgut; Matthias Wolf; Mathias Glehr; Andreas Leithner; Patrick Sadoghi
Journal:  Int Orthop       Date:  2013-12-18       Impact factor: 3.075

10.  Accurate alignment and high function after kinematically aligned TKA performed with generic instruments.

Authors:  Stephen M Howell; Stelios Papadopoulos; Kyle T Kuznik; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-15       Impact factor: 4.342

View more
  21 in total

1.  Kinematic versus mechanical alignment for primary total knee replacement: A systematic review and meta-analysis.

Authors:  Joshua Xu; Jacob Y Cao; Jason K Luong; Jonathan J Negus
Journal:  J Orthop       Date:  2019-02-28

2.  Posteromedial vertical capsulotomy selectively increases the extension gap in posterior stabilized total knee arthroplasty.

Authors:  Shin Masuda; Shinichi Miyazawa; Kodama Yuya; Yusuke Kamatski; Hino Tomohito; Okazaki Yoshiki; Okazaki Yuki; Takayuki Furumatsu; Toshifumi Ozaki
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-04-25       Impact factor: 4.342

3.  The orientation of the surgical epicondylar axis varies in varus and non-varus knees in the coronal plane.

Authors:  Yunjie Zhang; Xiaofeng Wang; Yunchao Shao; Qing Xia
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-11-28       Impact factor: 4.342

4.  Kinematically aligned total knee arthroplasty: alternative standardized technique?

Authors:  Tomoyuki Matsumoto; Koji Takayama; Kazunari Ishida; Shinya Hayashi; Shingo Hashimoto; Ryosuke Kuroda
Journal:  Ann Transl Med       Date:  2017-05

Review 5.  Current state of computer navigation and robotics in unicompartmental and total knee arthroplasty: a systematic review with meta-analysis.

Authors:  Jelle P van der List; Harshvardhan Chawla; Leo Joskowicz; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-09-06       Impact factor: 4.342

6.  Low tibial baseplate migration 1 year after unrestricted kinematically aligned total knee arthroplasty using a medial conforming implant design.

Authors:  Abigail E Niesen; Anna L Garverick; Stephen M Howell; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-10-06       Impact factor: 4.114

7.  Residual varus alignment can reduce joint awareness, restore joint parallelism, and preserve the soft tissue envelope during total knee arthroplasty for varus osteoarthritis.

Authors:  Kyun-Ho Shin; Ki-Mo Jang; Seung-Beom Han
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-08-03       Impact factor: 4.114

8.  Preoperative tibial mechanical axis orientation and articular surface design influence on the coronal joint line orientation relative to the ground during gait after total knee arthroplasties.

Authors:  Koji Murakami; Satoshi Hamai; Ken Okazaki; Satoru Ikebe; Hidehiko Higaki; Takeshi Shimoto; Yasuharu Nakashima
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-03-20       Impact factor: 4.342

Review 9.  Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty.

Authors:  Yong Seuk Lee; Stephen M Howell; Ye-Yeon Won; O-Sung Lee; Seung Hoon Lee; Hamed Vahedi; Seow Hui Teo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

10.  Kinematically aligned total knee arthroplasty reproduces native patellofemoral biomechanics during deep knee flexion.

Authors:  In Jun Koh; Il Jung Park; Charles C Lin; Nilay A Patel; Christen E Chalmers; Mauro Maniglio; Michelle H McGarry; Thay Q Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-28       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.