The effect of valgus/varus malalignment on load distribution in total knee replacements.

Frederick W Werner1, David C Ayers, Lorin P Maletsky, Paul J Rullkoetter.   

Abstract

Valgus or varus malpositioning of the tibial component of a total knee implant may cause increased propensity for loosening or implant wear and eventually may lead to revision surgery. The aim of this study was to determine the effect of valgus/varus malalignment on tibio-femoral mechanics during surgical trial reduction and simulated gait loading. In seven cadaver legs, posterior cruciate sparing total knee replacements were implanted and tibial inserts representing a neutral alignment and 3 degrees and 5 degrees varus and valgus alignments were sequentially inserted. Each knee with each insert was loaded in a manner representative of a trial reduction performed during knee surgery and loaded in a physiological knee simulator. Simulated gait performed on the simulator demonstrated that internal/external and adduction/abduction rotations showed statistical changes with some of the angled inserts at different points in the walking cycle. Neither medial/lateral nor anterior/posterior translations changed statistically during simulated walking. The pressure distribution and total load in the medial and lateral compartments of the tibial component changed significantly with as little as a 3 degrees variation in angulation when loaded in a manner representative of a trial reduction or with a knee simulator. These results support the need for precise surgical reconstruction of the mechanical axis of the knee and proper alignment of the tibial component. These results further demonstrate that tibial contact pressures measured during a trial reduction method may be predictive of contact mechanics at the higher loading seen in the knee simulator.

Entities:  

Mesh:

Year:  2005        PMID: 15598463     DOI: 10.1016/j.jbiomech.2004.02.024

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  79 in total

1.  Failure of tibial polyethylene insert locking mechanism in posterior stabilized arthroplasty.

Authors:  Emmanuel Thienpont
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-01       Impact factor: 4.342

2.  The limits of precision in conventionally instrumented computer-navigated total knee arthroplasty.

Authors:  R E da Assunção; N J Hancock; W J M Bruce; P Walker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-23       Impact factor: 4.342

Review 3.  How to read a postoperative knee replacement radiograph.

Authors:  Nawfal Al-Hadithy; Madhavan C Papanna; Sana Farooq; Yegappan Kalairajah
Journal:  Skeletal Radiol       Date:  2011-10-16       Impact factor: 2.199

4.  The Influence of Component Alignment and Ligament Properties on Tibiofemoral Contact Forces in Total Knee Replacement.

Authors:  Colin R Smith; Michael F Vignos; Rachel L Lenhart; Jarred Kaiser; Darryl G Thelen
Journal:  J Biomech Eng       Date:  2016-02       Impact factor: 2.097

Review 5.  [Axial correction in knee revision arthroplasty].

Authors:  C Perka; S Tohtz; G Matziolis
Journal:  Orthopade       Date:  2006-02       Impact factor: 1.087

6.  An aid to tibial alignment in total knee replacement.

Authors:  N J Cooke; R Burnett
Journal:  Ann R Coll Surg Engl       Date:  2008-01       Impact factor: 1.891

Review 7.  Navigation knee replacement.

Authors:  Rupen Dattani; Surendra Patnaik; Avadhoot Kantak; Georgis Tselentakis
Journal:  Int Orthop       Date:  2008-10-29       Impact factor: 3.075

8.  Patient-specific positioning guides do not consistently achieve the planned implant position in UKA.

Authors:  Justin A M J van Leeuwen; Stephan M Röhrl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-08-12       Impact factor: 4.342

Review 9.  Total knee arthroplasty in the varus knee: tips and tricks.

Authors:  Roberto Rossi; Umberto Cottino; Matteo Bruzzone; Federico Dettoni; Davide Edoardo Bonasia; Federica Rosso
Journal:  Int Orthop       Date:  2018-08-23       Impact factor: 3.075

10.  [Total knee arthroplasty with the use of patient specific instruments. The VISIONAIRE system].

Authors:  C O Tibesku
Journal:  Orthopade       Date:  2016-04       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.