Literature DB >> 25795248

Functional joint line obliquity after kinematic total knee arthroplasty.

Jonathan Hutt1, Vincent Massé1, Martin Lavigne1, Pascal-André Vendittoli2.   

Abstract

PURPOSE: Kinematic total knee arthroplasty (TKA) is an emerging technique, but concerns remain around the effect of implanting the prosthesis in more anatomic orientations. Native knees show variation in joint line orientation relative to the tibial mechanical axis but the joint line remains parallel to the floor when standing. This study was undertaken to evaluate joint line obliquity relative to the floor when weight-bearing after kinematic TKA to see if a similar effect occurs.
METHODS: Preoperative and postoperative measurements were taken for 55 consecutive kinematically aligned TKAs, including the joint line orientation angle (JLOA), formed between the joint line and a line parallel to the floor.
RESULTS: The mean medial proximal tibial angle (MPTA) was 3.4° varus pre-operatively (1.7° valgus to 7.9° varus, SD 2.0), and 3.0° varus postoperatively (5.5° valgus to 6.5° varus, SD 2.1). The mean postoperative JLOA was 1.0° varus with a smaller range than the MPTA (2.6° valgus to 6° varus, SD 1.9). The difference between these two measurements was significant (mean 2°, SD 2.5, p < 0.001).
CONCLUSIONS: Relative to the mechanical axis, 33 tibial components would be considered at risk outliers, being orientated at more than 3° in varus or valgus. However, only six components were outside this range relative to the vertical, all in varus (mean 4.2°). This latter measurement may better represent how the prosthesis is functionally loaded and is similar to mechanically aligned TKAs with good survivorship. This may help explain why kinematic alignment does not lead to higher earlier failure rates that may result if similar orientations were seen with mechanically aligned TKA.

Entities:  

Keywords:  Alignment; Kinematic; Orientation; TKA

Mesh:

Year:  2015        PMID: 25795248     DOI: 10.1007/s00264-015-2733-7

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  29 in total

1.  The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty.

Authors:  Xiaojun Shi; Bin Shen; Pengde Kang; Jing Yang; Zongke Zhou; Fuxing Pei
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-02       Impact factor: 4.342

2.  Press-fit condylar design total knee arthroplasty. Fourteen to seventeen-year follow-up.

Authors:  David J Rodricks; Shantanu Patil; Pamela Pulido; Clifford W Colwell
Journal:  J Bone Joint Surg Am       Date:  2007-01       Impact factor: 5.284

3.  Kinematically versus mechanically aligned total knee arthroplasty.

Authors:  H Gene Dossett; George J Swartz; Nicolette A Estrada; George W LeFevre; Bertram G Kwasman
Journal:  Orthopedics       Date:  2012-02-17       Impact factor: 1.390

4.  Retrieval analysis of posterior stabilized polyethylene tibial inserts and its clinical relevance.

Authors:  Hee-Nee Pang; Paul Jamieson; Matthew G Teeter; Richard W McCalden; Douglas D R Naudie; Steven J MacDonald
Journal:  J Arthroplasty       Date:  2013-07-01       Impact factor: 4.757

5.  Survivorship of cemented total knee arthroplasty.

Authors:  D E Font-Rodriguez; G R Scuderi; J N Insall
Journal:  Clin Orthop Relat Res       Date:  1997-12       Impact factor: 4.176

6.  Radiographic analysis of the axial alignment of the lower extremity.

Authors:  J R Moreland; L W Bassett; G J Hanker
Journal:  J Bone Joint Surg Am       Date:  1987-06       Impact factor: 5.284

7.  The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus.

Authors:  Johan Bellemans; William Colyn; Hilde Vandenneucker; Jan Victor
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

8.  Impact of the tibial slope on range of motion after low-contact-stress, mobile-bearing, total knee arthroplasty.

Authors:  Norbert Kastner; Simon Sternbauer; Jörg Friesenbichler; Ines Vielgut; Matthias Wolf; Mathias Glehr; Andreas Leithner; Patrick Sadoghi
Journal:  Int Orthop       Date:  2013-12-18       Impact factor: 3.075

9.  Kinematic factors affecting postoperative knee flexion after cruciate-retaining total knee arthroplasty.

Authors:  Tokio Matsuzaki; Tomoyuki Matsumoto; Hirotsugu Muratsu; Seiji Kubo; Takehiko Matsushita; Yohei Kawakami; Kazunari Ishida; Shinya Oka; Ryosuke Kuroda; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2013-03-05       Impact factor: 3.075

10.  Accurate alignment and high function after kinematically aligned TKA performed with generic instruments.

Authors:  Stephen M Howell; Stelios Papadopoulos; Kyle T Kuznik; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-15       Impact factor: 4.342

View more
  21 in total

1.  Letter to the Chief Editor regarding a recently published article entitled "No difference in outcomes and gait analysis between mechanical and kinematic knee alignment methods using robotic total knee arthroplasty".

Authors:  Charles Rivière
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-04       Impact factor: 4.342

2.  Kinematically aligned total knee arthroplasty: alternative standardized technique?

Authors:  Tomoyuki Matsumoto; Koji Takayama; Kazunari Ishida; Shinya Hayashi; Shingo Hashimoto; Ryosuke Kuroda
Journal:  Ann Transl Med       Date:  2017-05

3.  Tourniquet application during TKA did not affect the accuracy of implant positioning: a randomized clinical trial.

Authors:  Vera Stetzelberger; Udo Obertacke; Ahmed Jawhar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-10-20       Impact factor: 4.342

4.  Tibial joint line orientation has no effect on joint awareness after mechanically aligned total knee arthroplasty.

Authors:  Anna-Katharina Calek; Andreas Ladurner; Lukas Jud; Vilijam Zdravkovic; Henrik Behrend
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-08-21       Impact factor: 4.114

5.  Wide variation in tibial slopes and trochlear angles in the arthritic knee: a CT evaluation of 4116 pre-operative knees.

Authors:  Kaushik Hazratwala; William B O'Callaghan; Shilpa Dhariwal; Matthew P R Wilkinson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-09-06       Impact factor: 4.114

6.  Preoperative tibial mechanical axis orientation and articular surface design influence on the coronal joint line orientation relative to the ground during gait after total knee arthroplasties.

Authors:  Koji Murakami; Satoshi Hamai; Ken Okazaki; Satoru Ikebe; Hidehiko Higaki; Takeshi Shimoto; Yasuharu Nakashima
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-03-20       Impact factor: 4.342

Review 7.  Kinematic alignment is a possible alternative to mechanical alignment in total knee arthroplasty.

Authors:  Yong Seuk Lee; Stephen M Howell; Ye-Yeon Won; O-Sung Lee; Seung Hoon Lee; Hamed Vahedi; Seow Hui Teo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-04-24       Impact factor: 4.342

8.  Kinematically aligned TKA can align knee joint line to horizontal.

Authors:  Hyung-Min Ji; Jun Han; Dong San Jin; Hyunseok Seo; Ye-Yeon Won
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-25       Impact factor: 4.342

9.  Kinematically aligned total knee arthroplasty reproduces native patellofemoral biomechanics during deep knee flexion.

Authors:  In Jun Koh; Il Jung Park; Charles C Lin; Nilay A Patel; Christen E Chalmers; Mauro Maniglio; Michelle H McGarry; Thay Q Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-28       Impact factor: 4.342

10.  Kinematic alignment of medial UKA is safe: a systematic review.

Authors:  Charles Rivière; Sivan Sivaloganathan; Loic Villet; Philippe Cartier; Sébastien Lustig; Pascal-André Vendittoli; Justin Cobb
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-03-20       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.