Literature DB >> 26793688

Stereotactic vacuum-assisted breast biopsy under lateral decubitus position.

Sang Hyup Lee1, Youn Joo Jung1, Hyuk Jae Jung1, Jee Yeon Kim2, Ki Seok Choo3, Kyung Jin Nam3, Hyun Yul Kim1.   

Abstract

PURPOSE: Stereotactic vacuum-assisted breast biopsy (VAB) has been established as a standard method for histological diagnosis of microcalcification or nonpalpable breast lesions on mammography. Generally, the procedure has been done under the prone position or upright sitting position. We herein attempt to evaluate clinical utility of Stereotactic VAB under lateral decubitus position.
METHODS: One hundred six women (mean age, 51.2 years) with mammographically detected microcalcification underwent lateral decubitus positioning VAB using the 8G probe. In all cases, we obtained mammography specimens for identification of microcalcification and postprocedure mammography. We reviewed mean procedure time, pieces of specimen, pathology and follow-up mammography.
RESULTS: The procedure took approximately 20 minutes (range, 15-24 minutes). Average number of obtained specimens was 8.5 pieces (range, 6-12 pieces). Microcalcifications were confirmed in both specimen mammography and microscopic slides. Of 106 cases, 10 cases were diagnosed as ductal carcinoma in situ. Additional surgical management was performed. Atypical ductal hyperplasias were found in 8 cases, and fibrocystic changes in 88 cases.
CONCLUSION: Stereotactic VAB using the 8G probe under lateral decubitus position does not need a dedicated table, and is easier to maintain the position. Also, this procedure is accurate and safe. Thus, stereotactic VAB using the 8G probe under lateral decubitus position will be a useful method for diagnosis of microcalcification or nonpalpable breast lesions on mammography.

Entities:  

Keywords:  Biopsy; Breast; Lateral decubitus position; Microcalcification; Stereotactic techniques

Year:  2015        PMID: 26793688      PMCID: PMC4717604          DOI: 10.4174/astr.2016.90.1.16

Source DB:  PubMed          Journal:  Ann Surg Treat Res        ISSN: 2288-6575            Impact factor:   1.859


  9 in total

1.  Stereotactic core needle biopsy of nonpalpable breast lesions using a conventional mammography unit with an add-on device.

Authors:  Kevin J Kirshenbaum; Tripura Voruganti; Cornell Overbeeke; Myron D Kirshenbaum; Pravin Patel; Gerald Kaplan; Vijay Maker; Carey August; Robert P Cavallino
Journal:  AJR Am J Roentgenol       Date:  2003-08       Impact factor: 3.959

2.  Evaluation of mammographic and clinical follow-up after 755 stereotactic vacuum-assisted breast biopsies.

Authors:  Kerstin Rotter; Grit Haentschel; Doreen Koethe; Linda Goetz; A Bornhofen-Pöschke; Antje Lebrecht; Heinz Kölbl; Sylvia Heywang-Koebrunner
Journal:  Am J Surg       Date:  2003-08       Impact factor: 2.565

3.  Biopsy of breast microcalcifications using an 11-gauge directional vacuum-assisted device.

Authors:  H E Reynolds; C M Poon; R J Goulet; C L Lazaridis
Journal:  AJR Am J Roentgenol       Date:  1998-09       Impact factor: 3.959

4.  Stereotactic breast biopsy: comparison of 14- and 11-gauge Mammotome probe performance and complication rates.

Authors:  F Burbank
Journal:  Am Surg       Date:  1997-11       Impact factor: 0.688

5.  Efficacy of screening mammography. A meta-analysis.

Authors:  K Kerlikowske; D Grady; S M Rubin; C Sandrock; V L Ernster
Journal:  JAMA       Date:  1995-01-11       Impact factor: 56.272

6.  Vacuum-assisted stereotactic breast biopsy: histologic underestimation of malignant lesions.

Authors:  W E Burak; K E Owens; M B Tighe; L Kemp; S A Dinges; C L Hitchcock; J Olsen
Journal:  Arch Surg       Date:  2000-06

7.  Stereotactic breast biopsy: recumbent biopsy using add-on upright equipment.

Authors:  G J Welle; M Clark; S Loos; D Pauls; D Warden; M Sheffield; C Parsells
Journal:  AJR Am J Roentgenol       Date:  2000-07       Impact factor: 3.959

8.  Canceled stereotactic core-needle biopsy of the breast: analysis of 89 cases.

Authors:  L E Philpotts; C H Lee; L J Horvath; I Tocino
Journal:  Radiology       Date:  1997-11       Impact factor: 11.105

9.  Stereotactic breast biopsy of clustered microcalcifications with a directional, vacuum-assisted device.

Authors:  J E Meyer; D N Smith; P J DiPiro; C M Denison; T H Frenna; S C Harvey; W D Ko
Journal:  Radiology       Date:  1997-08       Impact factor: 11.105

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.