Literature DB >> 12885605

Evaluation of mammographic and clinical follow-up after 755 stereotactic vacuum-assisted breast biopsies.

Kerstin Rotter1, Grit Haentschel, Doreen Koethe, Linda Goetz, A Bornhofen-Pöschke, Antje Lebrecht, Heinz Kölbl, Sylvia Heywang-Koebrunner.   

Abstract

PURPOSE: Stereotactic vacuum-assisted breast biopsy (VB) is a new method that promises high accuracy and reliability. In order to avoid surgery in cases with benign histology the examination must be quality assured and the accuracy should be well established. We present follow-up data of 755 VBs with benign results.
METHODS: In all, 984 of 1268 consecutive VBs proved histopathologically benign (lobular carcinoma in situ and atypical ductal hyperplasia not included). Follow-up data are available for 755 of 984 (77%) lesions and constitute the basis of this evaluation. Follow-up mammograms were performed of 728 lesions at 6 to 67 months (mean 24, median 17.8) after VB.
RESULTS: Seven technically unsuccessful cases underwent immediate rebiopsy; 3 unsuccessful cases were diagnosed otherwise. No false negative occurred among the 752 followed-up, eventually successful VBs. On follow-up mammography 444 of 728 (61%) benign lesions proved radiologically completely removed, 284 (39%) partially. In 6 cases (0.8%) a surgical biopsy was performed again during the follow-up time confirming the benign result. No scar was seen in 96%, a slight scar in 3.8%, and a small stellate scar with possible diagnostic interference in 0.3%.
CONCLUSIONS: A benign diagnosis of quality assured VB is very reliable and leads to no or minimal scarring.

Entities:  

Mesh:

Year:  2003        PMID: 12885605     DOI: 10.1016/s0002-9610(03)00176-4

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  4 in total

1.  Stereotactic vacuum-assisted breast biopsy under lateral decubitus position.

Authors:  Sang Hyup Lee; Youn Joo Jung; Hyuk Jae Jung; Jee Yeon Kim; Ki Seok Choo; Kyung Jin Nam; Hyun Yul Kim
Journal:  Ann Surg Treat Res       Date:  2015-12-29       Impact factor: 1.859

2.  False-negative results after stereotactically guided vacuum biopsy.

Authors:  D Peter; J Grünhagen; R Wenke; F K W Schäfer; I Schreer
Journal:  Eur Radiol       Date:  2007-07-19       Impact factor: 5.315

3.  Stereotactic biopsy of the breast using a decubitus table: comparison of histologic underestimation rates between 11- and 8-gauge vacuum-assisted breast biopsy.

Authors:  Kyoung Eun Lee; Hak Hee Kim; Hee Jung Shin; Joo Hee Cha
Journal:  Springerplus       Date:  2013-10-22

4.  Does lateral arm technique decrease the rate of clip migration in stereotactic and tomosynthesis-guided biopsies?

Authors:  Olena Weaver; Ethan O Cohen; Rachel E Perry; Hilda H Tso; Kanchan Phalak; Ashmitha Srinivasan; Roland Bassett; Jessica W T Leung
Journal:  Insights Imaging       Date:  2021-12-20
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.