PURPOSE: The aim of this work was to develop and evaluate an MRI-based system for study of dynamic vocal tract shaping during speech production, which provides high spatial and temporal resolution. METHODS: The proposed system utilizes (a) custom eight-channel upper airway coils that have high sensitivity to upper airway regions of interest, (b) two-dimensional golden angle spiral gradient echo acquisition, (c) on-the-fly view-sharing reconstruction, and (d) off-line temporal finite difference constrained reconstruction. The system also provides simultaneous noise-cancelled and temporally aligned audio. The system is evaluated in 3 healthy volunteers, and 1 tongue cancer patient, with a broad range of speech tasks. RESULTS: We report spatiotemporal resolutions of 2.4 × 2.4 mm2 every 12 ms for single-slice imaging, and 2.4 × 2.4 mm2 every 36 ms for three-slice imaging, which reflects roughly 7-fold acceleration over Nyquist sampling. This system demonstrates improved temporal fidelity in capturing rapid vocal tract shaping for tasks, such as producing consonant clusters in speech, and beat-boxing sounds. Novel acoustic-articulatory analysis was also demonstrated. CONCLUSION: A synergistic combination of custom coils, spiral acquisitions, and constrained reconstruction enables visualization of rapid speech with high spatiotemporal resolution in multiple planes. Magn Reson Med 77:112-125, 2017.
PURPOSE: The aim of this work was to develop and evaluate an MRI-based system for study of dynamic vocal tract shaping during speech production, which provides high spatial and temporal resolution. METHODS: The proposed system utilizes (a) custom eight-channel upper airway coils that have high sensitivity to upper airway regions of interest, (b) two-dimensional golden angle spiral gradient echo acquisition, (c) on-the-fly view-sharing reconstruction, and (d) off-line temporal finite difference constrained reconstruction. The system also provides simultaneous noise-cancelled and temporally aligned audio. The system is evaluated in 3 healthy volunteers, and 1 tongue cancerpatient, with a broad range of speech tasks. RESULTS: We report spatiotemporal resolutions of 2.4 × 2.4 mm2 every 12 ms for single-slice imaging, and 2.4 × 2.4 mm2 every 36 ms for three-slice imaging, which reflects roughly 7-fold acceleration over Nyquist sampling. This system demonstrates improved temporal fidelity in capturing rapid vocal tract shaping for tasks, such as producing consonant clusters in speech, and beat-boxing sounds. Novel acoustic-articulatory analysis was also demonstrated. CONCLUSION: A synergistic combination of custom coils, spiral acquisitions, and constrained reconstruction enables visualization of rapid speech with high spatiotemporal resolution in multiple planes. Magn Reson Med 77:112-125, 2017.
Authors: Joao Fernando Kazan-Tannus; Deborah Levine; Charles McKenzie; Kee-Hak Lim; Bruce Cohen; Norman Farrar; Reed F Busse; John B Mulliken Journal: J Ultrasound Med Date: 2005-11 Impact factor: 2.153
Authors: Christina Hagedorn; Michael Proctor; Louis Goldstein; Stephen M Wilson; Bruce Miller; Maria Luisa Gorno-Tempini; Shrikanth S Narayanan Journal: J Speech Lang Hear Res Date: 2017-04-14 Impact factor: 2.297
Authors: Adrienne E Campbell-Washburn; Rajiv Ramasawmy; Matthew C Restivo; Ipshita Bhattacharya; Burcu Basar; Daniel A Herzka; Michael S Hansen; Toby Rogers; W Patricia Bandettini; Delaney R McGuirt; Christine Mancini; David Grodzki; Rainer Schneider; Waqas Majeed; Himanshu Bhat; Hui Xue; Joel Moss; Ashkan A Malayeri; Elizabeth C Jones; Alan P Koretsky; Peter Kellman; Marcus Y Chen; Robert J Lederman; Robert S Balaban Journal: Radiology Date: 2019-10-01 Impact factor: 11.105
Authors: Xue Feng; Silvia S Blemker; Josh Inouye; Catherine M Pelland; Li Zhao; Craig H Meyer Journal: Magn Reson Med Date: 2018-03-05 Impact factor: 4.668