Literature DB >> 25647755

Acceleration of MRI of the vocal tract provides additional insight into articulator modifications.

Michael Burdumy1,2, Louisa Traser2,3, Bernhard Richter2, Matthias Echternach2, Jan G Korvink4, Jürgen Hennig1, Maxim Zaitsev1.   

Abstract

PURPOSE: To accelerate dynamic imaging of the vocal tract during articulation.
MATERIALS AND METHODS: Five subjects were imaged by magnetic resonance imaging (MRI) while repeating the word "Partikel" at 90 beats per minute, using both a radio-frequency-spoiled radial gradient echo sequence with golden angle projection rotation and a previously applied real-time Cartesian sequence. The acquired data were reconstructed using a CG-SENSE method and Cartesian reconstruction. The images from both methods were compared by measuring distances between anatomical landmarks that are important for resonance behavior of the vocal tract. Only commonly available hardware and software were used.
RESULTS: With the presented radial method a spatial resolution of 1.8 mm at 25 frames per second could be achieved. Overall, the morphometric measurements of the vocal tract showed less deviation for the radial sequence both across repetitions and for all subjects. Fast modifications, such as complete lip closing, could be analyzed with greater fidelity using the high temporal resolution of the radial sequence.
CONCLUSION: The results indicate that higher temporal resolution is a necessity to catch fast morphometric changes in the vocal tract.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  non-Cartesian trajectory; real time imaging; singer imaging; speech MRI

Mesh:

Year:  2015        PMID: 25647755     DOI: 10.1002/jmri.24857

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  7 in total

Review 1.  Recommendations for real-time speech MRI.

Authors:  Sajan Goud Lingala; Brad P Sutton; Marc E Miquel; Krishna S Nayak
Journal:  J Magn Reson Imaging       Date:  2015-07-14       Impact factor: 4.813

2.  Assessment of velopharyngeal function with dual-planar high-resolution real-time spiral dynamic MRI.

Authors:  Xue Feng; Silvia S Blemker; Josh Inouye; Catherine M Pelland; Li Zhao; Craig H Meyer
Journal:  Magn Reson Med       Date:  2018-03-05       Impact factor: 4.668

3.  A fast and flexible MRI system for the study of dynamic vocal tract shaping.

Authors:  Sajan Goud Lingala; Yinghua Zhu; Yoon-Chul Kim; Asterios Toutios; Shrikanth Narayanan; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2016-01-17       Impact factor: 4.668

4.  Multimodal dataset of real-time 2D and static 3D MRI of healthy French speakers.

Authors:  Karyna Isaieva; Yves Laprie; Justine Leclère; Ioannis K Douros; Jacques Felblinger; Pierre-André Vuissoz
Journal:  Sci Data       Date:  2021-10-01       Impact factor: 6.444

5.  Sub-millisecond 2D MRI of the vocal fold oscillation using single-point imaging with rapid encoding.

Authors:  Johannes Fischer; Ali Caglar Özen; Serhat Ilbey; Louisa Traser; Matthias Echternach; Bernhard Richter; Michael Bock
Journal:  MAGMA       Date:  2021-09-20       Impact factor: 2.310

6.  Comparison of Cartesian and Non-Cartesian Real-Time MRI Sequences at 1.5T to Assess Velar Motion and Velopharyngeal Closure during Speech.

Authors:  Andreia C Freitas; Marzena Wylezinska; Malcolm J Birch; Steffen E Petersen; Marc E Miquel
Journal:  PLoS One       Date:  2016-04-13       Impact factor: 3.240

7.  Morphometric Differences of Vocal Tract Articulators in Different Loudness Conditions in Singing.

Authors:  Matthias Echternach; Fabian Burk; Michael Burdumy; Louisa Traser; Bernhard Richter
Journal:  PLoS One       Date:  2016-04-20       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.