Literature DB >> 26715558

Comparison of iterative model, hybrid iterative, and filtered back projection reconstruction techniques in low-dose brain CT: impact of thin-slice imaging.

Takeshi Nakaura1,2, Yuji Iyama3,4, Masafumi Kidoh3,4, Koichi Yokoyama3,4, Seitaro Oda4, Shinichi Tokuyasu5, Kazunori Harada6, Yasuyuki Yamashita4.   

Abstract

INTRODUCTION: The purpose of this study was to evaluate the utility of iterative model reconstruction (IMR) in brain CT especially with thin-slice images.
METHODS: This prospective study received institutional review board approval, and prior informed consent to participate was obtained from all patients. We enrolled 34 patients who underwent brain CT and reconstructed axial images with filtered back projection (FBP), hybrid iterative reconstruction (HIR) and IMR with 1 and 5 mm slice thicknesses. The CT number, image noise, contrast, and contrast noise ratio (CNR) between the thalamus and internal capsule, and the rate of increase of image noise in 1 and 5 mm thickness images between the reconstruction methods, were assessed. Two independent radiologists assessed image contrast, image noise, image sharpness, and overall image quality on a 4-point scale.
RESULTS: The CNRs in 1 and 5 mm slice thickness were significantly higher with IMR (1.2 ± 0.6 and 2.2 ± 0.8, respectively) than with FBP (0.4 ± 0.3 and 1.0 ± 0.4, respectively) and HIR (0.5 ± 0.3 and 1.2 ± 0.4, respectively) (p < 0.01). The mean rate of increasing noise from 5 to 1 mm thickness images was significantly lower with IMR (1.7 ± 0.3) than with FBP (2.3 ± 0.3) and HIR (2.3 ± 0.4) (p < 0.01). There were no significant differences in qualitative analysis of unfamiliar image texture between the reconstruction techniques.
CONCLUSION: IMR offers significant noise reduction and higher contrast and CNR in brain CT, especially for thin-slice images, when compared to FBP and HIR.

Entities:  

Keywords:  Brain; CT; Iterative reconstruction; Radiation dose

Mesh:

Year:  2015        PMID: 26715558     DOI: 10.1007/s00234-015-1631-4

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  29 in total

1.  Correlation of apparent diffusion coefficient and computed tomography density in acute ischemic stroke.

Authors:  T Dóczi; A Schwarcz
Journal:  Stroke       Date:  2003-04-24       Impact factor: 7.914

2.  Quality initiatives: CT radiation dose reduction: how to implement change without sacrificing diagnostic quality.

Authors:  Eric P Tamm; X John Rong; Dianna D Cody; Randy D Ernst; Nancy E Fitzgerald; Vikas Kundra
Journal:  Radiographics       Date:  2011-10-03       Impact factor: 5.333

3.  Using the baseline CT scan to select acute stroke patients for IV-IA therapy.

Authors:  M D Hill; A M Demchuk; T A Tomsick; Y Y Palesch; J P Broderick
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

Review 4.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

5.  Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels.

Authors:  A Löve; M-L Olsson; R Siemund; F Stålhammar; I M Björkman-Burtscher; M Söderberg
Journal:  Br J Radiol       Date:  2013-09-18       Impact factor: 3.039

6.  Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR).

Authors:  S Notohamiprodjo; Z Deak; F Meurer; F Maertz; F G Mueck; L L Geyer; S Wirth
Journal:  Eur Radiol       Date:  2014-08-06       Impact factor: 5.315

7.  Model-based iterative reconstruction for detection of subtle hypoattenuation in early cerebral infarction: a phantom study.

Authors:  Mitsuo Nishizawa; Hisashi Tanaka; Yoshiyuki Watanabe; Yuuki Kunitomi; Akio Tsukabe; Noriyuki Tomiyama
Journal:  Jpn J Radiol       Date:  2014-11-26       Impact factor: 2.374

Review 8.  Neuroimaging in traumatic brain imaging.

Authors:  Bruce Lee; Andrew Newberg
Journal:  NeuroRx       Date:  2005-04

9.  Utility of magnetic resonance cisternography using three-dimensional fast asymmetric spin-echo sequences with multiplanar reconstruction: the evaluation of sites of neurovascular compression of the trigeminal nerve.

Authors:  Tatsurou Tanaka; Yasuhiro Morimoto; Shunji Shiiba; Eiji Sakamoto; Shinji Kito; Yuka Matsufuji; Osamu Nakanishi; Takeshi Ohba
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2005-08

10.  Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults.

Authors:  Aaron Sodickson; Pieter F Baeyens; Katherine P Andriole; Luciano M Prevedello; Richard D Nawfel; Richard Hanson; Ramin Khorasani
Journal:  Radiology       Date:  2009-04       Impact factor: 11.105

View more
  13 in total

Review 1.  Routine postoperative computed tomography scan after craniotomy: systematic review and evidence-based recommendations.

Authors:  Lukas Blumrich; João Paulo Mota Telles; Saul Almeida da Silva; Ricardo Ferrareto Iglesio; Manoel Jacobsen Teixeira; Eberval Gadelha Figueiredo
Journal:  Neurosurg Rev       Date:  2021-01-15       Impact factor: 3.042

2.  Diagnosis of small posterior fossa stroke on brain CT: effect of iterative reconstruction designed for brain CT on detection performance.

Authors:  Taihei Inoue; Takeshi Nakaura; Morikatsu Yoshida; Koichi Yokoyama; Kenichiro Hirata; Masafumi Kidoh; Seitaro Oda; Daisuke Utsunomiya; Kazunori Harada; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2017-03-08       Impact factor: 5.315

3.  "Hyperdense artery sign" in early ischemic stroke: diagnostic value of model-based reconstruction approach in comparison with standard hybrid iterative reconstruction algorithm.

Authors:  Sophie Lombardi; Luca Riva; Mirko Patassini; Paolo Remida; Cristina Capraro; Francesco Canonico; Cammillo Talei Franzesi; Davide Ippolito
Journal:  Neuroradiology       Date:  2018-09-08       Impact factor: 2.804

4.  Image Quality Required for the Diagnosis of Skull Fractures Using Head CT: A Comparison of Conventional and Improved Reconstruction Kernels.

Authors:  S Takagi; M Koyama; K Hayashi; T Kawauchi
Journal:  AJNR Am J Neuroradiol       Date:  2016-07-14       Impact factor: 3.825

5.  Optimal slice thickness of brain computed tomography using a hybrid iterative reconstruction algorithm for identifying hyperdense middle cerebral artery sign of acute ischemic stroke.

Authors:  Shota Ichikawa; Misaki Hamada; Daiki Watanabe; Osamu Ito; Takafumi Moriya; Hiroyuki Yamamoto
Journal:  Emerg Radiol       Date:  2020-10-14

6.  Evaluation of Apparent Noise on CT Images Using Moving Average Filters.

Authors:  Keisuke Fujii; Keiichi Nomura; Kuniharu Imai; Yoshihisa Muramatsu; So Tsushima; Hiroyuki Ota
Journal:  J Digit Imaging       Date:  2021-11-10       Impact factor: 4.056

7.  CT reconstruction algorithms affect histogram and texture analysis: evidence for liver parenchyma, focal solid liver lesions, and renal cysts.

Authors:  Su Joa Ahn; Jung Hoon Kim; Sang Min Lee; Sang Joon Park; Joon Koo Han
Journal:  Eur Radiol       Date:  2018-11-19       Impact factor: 5.315

8.  Could new reconstruction CT techniques challenge MRI for the detection of brain metastases in the context of initial lung cancer staging?

Authors:  Domitille Millon; David Byl; Philippe Collard; Samantha E Cambier; Aline G Van Maanen; Alain Vlassenbroek; Emmanuel E Coche
Journal:  Eur Radiol       Date:  2017-08-30       Impact factor: 5.315

9.  Accuracy of thin-slice model-based iterative reconstruction designed for brain CT to diagnose acute ischemic stroke in the middle cerebral artery territory: a multicenter study.

Authors:  Hidenori Mitani; Fuminari Tatsugami; Toru Higaki; Yoko Kaichi; Yuko Nakamura; Ewoud Smit; Mathias Prokop; Chiaki Ono; Ken Ono; Yukunori Korogi; Kazuo Awai
Journal:  Neuroradiology       Date:  2021-06-30       Impact factor: 2.804

10.  Brain computed tomography using iterative reconstruction to diagnose acute middle cerebral artery stroke: usefulness in combination of narrow window setting and thin slice reconstruction.

Authors:  Taihei Inoue; Takeshi Nakaura; Morikatsu Yoshida; Koichi Yokoyama; Hiroyuki Uetani; Seitaro Oda; Daisuke Utsunomiya; Mika Kitajima; Kazunori Harada; Yasuyuki Yamashita
Journal:  Neuroradiology       Date:  2018-02-23       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.