Literature DB >> 25097137

Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR).

S Notohamiprodjo1, Z Deak, F Meurer, F Maertz, F G Mueck, L L Geyer, S Wirth.   

Abstract

OBJECTIVES: The purpose of this study was to compare cranial CT (CCT) image quality (IQ) of the MBIR algorithm with standard iterative reconstruction (ASiR).
METHODS: In this institutional review board (IRB)-approved study, raw data sets of 100 unenhanced CCT examinations (120 kV, 50-260 mAs, 20 mm collimation, 0.984 pitch) were reconstructed with both ASiR and MBIR. Signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated from attenuation values measured in caudate nucleus, frontal white matter, anterior ventricle horn, fourth ventricle, and pons. Two radiologists, who were blinded to the reconstruction algorithms, evaluated anonymized multiplanar reformations of 2.5 mm with respect to depiction of different parenchymal structures and impact of artefacts on IQ with a five-point scale (0: unacceptable, 1: less than average, 2: average, 3: above average, 4: excellent).
RESULTS: MBIR decreased artefacts more effectively than ASiR (p < 0.01). The median depiction score for MBIR was 3, whereas the median value for ASiR was 2 (p < 0.01). SNR and CNR were significantly higher in MBIR than ASiR (p < 0.01).
CONCLUSIONS: MBIR showed significant improvement of IQ parameters compared to ASiR. As CCT is an examination that is frequently required, the use of MBIR may allow for substantial reduction of radiation exposure caused by medical diagnostics. KEY POINTS: • Model-Based iterative reconstruction (MBIR) effectively decreased artefacts in cranial CT. • MBIR reconstructed images were rated with significantly higher scores for image quality. • Model-Based iterative reconstruction may allow reduced-dose diagnostic examination protocols.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25097137     DOI: 10.1007/s00330-014-3374-8

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  35 in total

1.  Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: a pilot study.

Authors:  Yoshitake Yamada; Masahiro Jinzaki; Yutaka Tanami; Eisuke Shiomi; Hiroaki Sugiura; Takayuki Abe; Sachio Kuribayashi
Journal:  Invest Radiol       Date:  2012-08       Impact factor: 6.016

2.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

Review 3.  Innovations in CT dose reduction strategy: application of the adaptive statistical iterative reconstruction algorithm.

Authors:  Alvin C Silva; Holly J Lawder; Amy Hara; Jennifer Kujak; William Pavlicek
Journal:  AJR Am J Roentgenol       Date:  2010-01       Impact factor: 3.959

4.  Noise-based tube current reduction method with iterative reconstruction for reduction of radiation exposure in coronary CT angiography.

Authors:  Junlin Shen; Xiangying Du; Daode Guo; Lizhen Cao; Yan Gao; Mei Bai; Pengyu Li; Jiabin Liu; Kuncheng Li
Journal:  Eur J Radiol       Date:  2012-11-07       Impact factor: 3.528

5.  Filtered back projection, adaptive statistical iterative reconstruction, and a model-based iterative reconstruction in abdominal CT: an experimental clinical study.

Authors:  Zsuzsanna Deák; Jochen M Grimm; Marcus Treitl; Lucas L Geyer; Ulrich Linsenmaier; Markus Körner; Maximilian F Reiser; Stefan Wirth
Journal:  Radiology       Date:  2012-11-20       Impact factor: 11.105

6.  Iterative reconstruction techniques for computed tomography Part 1: technical principles.

Authors:  Martin J Willemink; Pim A de Jong; Tim Leiner; Linda M de Heer; Rutger A J Nievelstein; Ricardo P J Budde; Arnold M R Schilham
Journal:  Eur Radiol       Date:  2013-01-12       Impact factor: 5.315

7.  National trends in CT use in the emergency department: 1995-2007.

Authors:  David B Larson; Lara W Johnson; Beverly M Schnell; Shelia R Salisbury; Howard P Forman
Journal:  Radiology       Date:  2010-11-29       Impact factor: 11.105

8.  Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product.

Authors:  Paul D Deak; Yulia Smal; Willi A Kalender
Journal:  Radiology       Date:  2010-10       Impact factor: 11.105

9.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

10.  Emergency department computed tomography utilization in the United States and Canada.

Authors:  Carl T Berdahl; Marian J Vermeulen; David B Larson; Michael J Schull
Journal:  Ann Emerg Med       Date:  2013-05-14       Impact factor: 5.721

View more
  13 in total

1.  Image quality and dose optimisation for infant CT using a paediatric phantom.

Authors:  Jack W Lambert; Andrew S Phelps; Jesse L Courtier; Robert G Gould; John D MacKenzie
Journal:  Eur Radiol       Date:  2015-08-26       Impact factor: 5.315

2.  Comparison of iterative model, hybrid iterative, and filtered back projection reconstruction techniques in low-dose brain CT: impact of thin-slice imaging.

Authors:  Takeshi Nakaura; Yuji Iyama; Masafumi Kidoh; Koichi Yokoyama; Seitaro Oda; Shinichi Tokuyasu; Kazunori Harada; Yasuyuki Yamashita
Journal:  Neuroradiology       Date:  2015-12-29       Impact factor: 2.804

3.  A "one-stop-shop" 4D CTA protocol using 320-row CT for advanced imaging in acute ischemic stroke: a technical note.

Authors:  Julien Ognard; Brieg Dissaux; Karim Haioun; Michel Nonent; Jean-Christophe Gentric; Douraïed Ben Salem
Journal:  Eur Radiol       Date:  2019-02-15       Impact factor: 5.315

4.  "Hyperdense artery sign" in early ischemic stroke: diagnostic value of model-based reconstruction approach in comparison with standard hybrid iterative reconstruction algorithm.

Authors:  Sophie Lombardi; Luca Riva; Mirko Patassini; Paolo Remida; Cristina Capraro; Francesco Canonico; Cammillo Talei Franzesi; Davide Ippolito
Journal:  Neuroradiology       Date:  2018-09-08       Impact factor: 2.804

5.  Comparison of Iterative Model Reconstruction versus Filtered Back-Projection in Pediatric Emergency Head CT: Dose, Image Quality, and Image-Reconstruction Times.

Authors:  R N Southard; D M E Bardo; M H Temkit; M A Thorkelson; R A Augustyn; C A Martinot
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-11       Impact factor: 3.825

6.  Image Quality Required for the Diagnosis of Skull Fractures Using Head CT: A Comparison of Conventional and Improved Reconstruction Kernels.

Authors:  S Takagi; M Koyama; K Hayashi; T Kawauchi
Journal:  AJNR Am J Neuroradiol       Date:  2016-07-14       Impact factor: 3.825

7.  Submillisievert CT using model-based iterative reconstruction with lung-specific setting: An initial phantom study.

Authors:  Akinori Hata; Masahiro Yanagawa; Osamu Honda; Tomoko Gyobu; Ken Ueda; Noriyuki Tomiyama
Journal:  Eur Radiol       Date:  2016-03-17       Impact factor: 5.315

8.  Diagnostic accuracy of contemporary multidetector computed tomography (MDCT) for the detection of lumbar disc herniation.

Authors:  S Notohamiprodjo; R Stahl; M Braunagel; P M Kazmierczak; K M Thierfelder; K M Treitl; S Wirth; M Notohamiprodjo
Journal:  Eur Radiol       Date:  2016-12-17       Impact factor: 5.315

9.  Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study.

Authors:  Fiachra Moloney; Karl James; Maria Twomey; David Ryan; Tyler M Grey; Amber Downes; Richard G Kavanagh; Niamh Moore; Mary Jane Murphy; Jackie Bye; Brian W Carey; Sean E McSweeney; Conor Deasy; Emmett Andrews; Fergus Shanahan; Michael M Maher; Owen J O'Connor
Journal:  Emerg Radiol       Date:  2018-11-17

10.  Could new reconstruction CT techniques challenge MRI for the detection of brain metastases in the context of initial lung cancer staging?

Authors:  Domitille Millon; David Byl; Philippe Collard; Samantha E Cambier; Aline G Van Maanen; Alain Vlassenbroek; Emmanuel E Coche
Journal:  Eur Radiol       Date:  2017-08-30       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.