Literature DB >> 26660728

Causes for revision of dual-mobility and standard primary total hip arthroplasty : Matched case-control study based on a prospective multicenter study of two thousand and forty four implants.

Jean-Louis Prudhon1, Romain Desmarchelier2, Moussa Hamadouche3, Christian Delaunay4, Régis Verdier5.   

Abstract

INTRODUCTION: The causes for revision of primary total hip arthroplasty (THA) are various and quite well known. The developing use of dual-mobility THA (DM-THA) seems a relevant option to decrease the risk of instability. Due to lack of long-term follow-up, this innovative retentive concept is suspected to increase the risk of polyethylene (PE) wear. the aim of the study was to analyse the causes for DM-THA revision and assess whether or not its occurrence is different from that of fixed-standard (FS) THA , particularly for aseptic loosening or wear and/or osteolysis.
MATERIALS AND METHODS: The SoFCOT group conducted an observational prospective multicentre study from 1 January 2010 to 31 December 2011. Inclusion criteria comprised an exhaustive collection of 2044 first-revision THAs with 251 DM-THAs and 1793 FS-THAs. After excluding complications linked to patient factors (infection and periprosthetic fractures), we performed a matched case-control study (matching ratio 1:1) comparing two groups of 133 THAs.
RESULTS: Revisions for aseptic loosening or osteolysis/wear were as frequent in DM-THA (58.7 %) as in FS-THA (57.1 %) (p 0.32); 7.5 % of DM-THA were revised for dislocation versus 19.5 % of FS-THA (p 0.007). DISCUSSION: Revision for osteolysis/wear and aseptic loosening were as frequent in DM-THA as in FS-THA; revision for dislocation was less frequent in DM-THA. This confirms the efficiency of the DM concept regarding the risk of dislocation. Causes for revision were different between groups, and revisions for dislocation were less frequent in DM-THA. Only prospective comparative studies could provide reliable information that may support broader use of the DM concept.

Entities:  

Keywords:  Dual mobility; Revision; Total hip arthroplasty

Mesh:

Year:  2015        PMID: 26660728     DOI: 10.1007/s00264-015-3064-4

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  27 in total

1.  Is a cementless dual mobility socket in primary THA a reasonable option?

Authors:  Moussa Hamadouche; Hervé Arnould; Bertrand Bouxin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Evora® chromium-cobalt dual mobility socket: results at a minimum 10 years' follow-up.

Authors:  S Leclercq; J Y Benoit; J P de Rosa; E Tallier; C Leteurtre; P H Girardin
Journal:  Orthop Traumatol Surg Res       Date:  2013-10-29       Impact factor: 2.256

3.  Clinical outcomes, survivorship and adverse events with mobile-bearings versus fixed-bearings in hip arthroplasty-a prospective comparative cohort study of 143 ADM versus 130 trident cups at 2 to 6-year follow-up.

Authors:  Jean-Alain Epinette
Journal:  J Arthroplasty       Date:  2014-10-02       Impact factor: 4.757

Review 4.  Biomechanical concept and clinical outcome of dual mobility cups.

Authors:  Aron Grazioli; Eugene Teow Hin Ek; Hannes Andreas Rüdiger
Journal:  Int Orthop       Date:  2012-10-17       Impact factor: 3.075

5.  Intraprosthetic dislocation: a specific complication of the dual-mobility system.

Authors:  Remi Philippot; Bertrand Boyer; Frederic Farizon
Journal:  Clin Orthop Relat Res       Date:  2012-10-10       Impact factor: 4.176

Review 6.  Risk factors for periprosthetic joint infection after total joint arthroplasty: a systematic review and meta-analysis.

Authors:  Y Zhu; F Zhang; W Chen; S Liu; Q Zhang; Y Zhang
Journal:  J Hosp Infect       Date:  2014-12-04       Impact factor: 3.926

7.  Three-dimensional polyethylene wear of a press-fit titanium prosthesis. Factors influencing generation of polyethylene debris.

Authors:  P A Devane; J G Horne; K Martin; G Coldham; B Krause
Journal:  J Arthroplasty       Date:  1997-04       Impact factor: 4.757

8.  Verification of the Australian Orthopaedic Association National Joint Replacement Registry using a surgeon's database.

Authors:  Bob Jang; Nichola A Walsh; Warwick J M Bruce
Journal:  J Orthop Surg (Hong Kong)       Date:  2013-12       Impact factor: 1.118

9.  A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk.

Authors:  Jacques H Caton; Jean Louis Prudhon; André Ferreira; Thierry Aslanian; Régis Verdier
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

10.  The use of dual-mobility components in total hip arthroplasty.

Authors:  Paul F Lachiewicz; Tyler Steven Watters
Journal:  J Am Acad Orthop Surg       Date:  2012-08       Impact factor: 3.020

View more
  15 in total

1.  Results of primary total hip replacement with first generation Bousquet dual mobility socket with more than twenty five years follow up. About a series of two hundred and twelve hips.

Authors:  Thomas Neri; Remi Philippot; Frederic Farizon; Bertrand Boyer
Journal:  Int Orthop       Date:  2016-12-26       Impact factor: 3.075

2.  Dual-mobility cup: a new French revolution.

Authors:  Jacques Henri Caton; André Ferreira
Journal:  Int Orthop       Date:  2017-02-14       Impact factor: 3.075

Review 3.  The evolution of outcomes and indications for the dual-mobility cup: a systematic review.

Authors:  Cécile Batailler; Camdon Fary; Régis Verdier; Thierry Aslanian; Jacques Caton; Sebastien Lustig
Journal:  Int Orthop       Date:  2016-12-21       Impact factor: 3.075

Review 4.  Dual-mobility arthroplasty failure: a rationale review of causes and technical considerations for revision.

Authors:  Philippe Hernigou; Arnaud Dubory; Damien Potage; François Roubineau; Charles Henri Flouzat Lachaniette
Journal:  Int Orthop       Date:  2016-11-21       Impact factor: 3.075

5.  Total hip arthroplasty with dual mobility cup in osteonecrosis of the femoral head in young patients: over ten years of follow-up.

Authors:  Pierre Martz; Alexandre Maczynski; Sebastien Elsair; Ludovic Labattut; Brice Viard; Emmanuel Baulot
Journal:  Int Orthop       Date:  2016-11-25       Impact factor: 3.075

6.  Poor performance of Enduron polyethylene liner in total hip arthroplasty: a minimum ten-year follow up and ultra-morphological analysis of wear particles.

Authors:  Yufei Yan; Hao Chen; Jianmin Feng; Kaizhe Chen; Kaidi Zhou; Weixiang Hong; Yi Wang; Zhihong Liu; Jiong Zhang; Qingming Yang; Lei Guo; Chuan He
Journal:  Int Orthop       Date:  2016-05-13       Impact factor: 3.075

7.  Dual-mobility implants prevent hip dislocation following hip revision in obese patients.

Authors:  Philippe Hernigou; Jean Charles Auregan; Damien Potage; François Roubineau; Charles Henri Flouzat Lachaniette; Arnaud Dubory
Journal:  Int Orthop       Date:  2016-10-20       Impact factor: 3.075

8.  Low friction arthroplasty and dual mobility cup: a new gold standard.

Authors:  Jean Louis Prudhon; Régis Verdier; Jacques H Caton
Journal:  Int Orthop       Date:  2016-12-20       Impact factor: 3.075

9.  The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies.

Authors:  Matteo Romagnoli; Alberto Grassi; Giuseppe Gianluca Costa; Lionel E Lazaro; Mirco Lo Presti; Stefano Zaffagnini
Journal:  Int Orthop       Date:  2018-07-21       Impact factor: 3.075

Review 10.  Risk of revision and dislocation in single, dual mobility and large femoral head total hip arthroplasty: systematic review and network meta-analysis.

Authors:  Kwanchai Pituckanotai; Alisara Arirachakaran; Harit Tuchinda; Chinundorn Putananon; Nitiphol Nualsalee; Kittipong Setrkraising; Jatupon Kongtharvonskul
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-11-08
View more