Literature DB >> 22855850

The use of dual-mobility components in total hip arthroplasty.

Paul F Lachiewicz1, Tyler Steven Watters.   

Abstract

Dual-mobility hip components provide for an additional articular surface, with the goal of improving range of motion, jump distance (ie, vertical or inferior head displacement required for dislocation), and stability of the total hip arthroplasty. A large polyethylene head articulates with a polished metal acetabular component, and an additional smaller metal head is snap-fit within the polyethylene. New components have recently been released for use in North America. Although these devices are routinely used in some European centers for primary hip arthroplasty, their greatest utility may be to manage recurrent dislocation in the setting of revision hip arthroplasty. Several small retrospective series have shown satisfactory results for this indication at short- to midterm follow-up. Polyethylene wear and intraprosthetic dislocation are concerns, as is the lack of long-term data. Caution is thus advised in the routine use of dual-mobility components in primary and revision total hip arthroplasty.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22855850     DOI: 10.5435/JAAOS-20-08-481

Source DB:  PubMed          Journal:  J Am Acad Orthop Surg        ISSN: 1067-151X            Impact factor:   3.020


  14 in total

1.  Revision for taper corrosion at the neck-body junction following total hip arthroplasty: pearls and pitfalls.

Authors:  Mitchell C Weiser; Darwin D Chen
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

2.  Outcomes of dual mobility cups in a young Middle Eastern population and its influence on life style.

Authors:  Chahine Assi; Elie El-Najjar; Camille Samaha; Kaissar Yammine
Journal:  Int Orthop       Date:  2017-01-10       Impact factor: 3.075

3.  The focally constrained liner is a reasonable option for revision of unstable total hip arthroplasty.

Authors:  Tatu J Mäkinen; Simcha G Fichman; Wael A Rahman; Tomas Amenabar; Oleg Safir; Allan E Gross; Paul R T Kuzyk
Journal:  Int Orthop       Date:  2015-12-23       Impact factor: 3.075

Review 4.  Dissociation and Intrapelvic Entrapment of a Dual-mobility Polyethylene Component.

Authors:  Keith A Fehring; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2015-06-19       Impact factor: 4.176

5.  A comparative and retrospective study of three hundred and twenty primary Charnley type hip replacements with a minimum follow up of ten years to assess whether a dual mobility cup has a decreased dislocation risk.

Authors:  Jacques H Caton; Jean Louis Prudhon; André Ferreira; Thierry Aslanian; Régis Verdier
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

6.  Causes for revision of dual-mobility and standard primary total hip arthroplasty : Matched case-control study based on a prospective multicenter study of two thousand and forty four implants.

Authors:  Jean-Louis Prudhon; Romain Desmarchelier; Moussa Hamadouche; Christian Delaunay; Régis Verdier
Journal:  Int Orthop       Date:  2015-12-14       Impact factor: 3.075

7.  Ischiofemoral hip ligament reconstructions for recurrent posterior total hip joint dislocations.

Authors:  Mohamed Ridzwan Bin Mohamed Namazie; Alastair T Hadlow
Journal:  J Orthop       Date:  2018-08-16

8.  Dual mobility THR: Resolving instability and providing near normal range of movement.

Authors:  Sanjay Agarwala; Vivek Shetty; Shounak Taywade; Mayank Vijayvargiya; Mahmoud Bhingraj
Journal:  J Clin Orthop Trauma       Date:  2020-08-28

9.  Early results of total hip arthroplasty using dual-mobility cup in patients with osteonecrosis of the femoral head.

Authors:  Chahine Assi; Nadim Kheir; Camille Samaha; Pascal Kouyoumjian; Kaissar Yammine
Journal:  SICOT J       Date:  2018-02-21

10.  THA for a Fractured Femoral Neck: Comparing the Revision and Dislocation Rates of Standard-head, Large-head, Dual-mobility, and Constrained Liners.

Authors:  Wayne Hoskins; Xavier Griffin; Alesha Hatton; Richard N de Steiger; Roger Bingham
Journal:  Clin Orthop Relat Res       Date:  2021-01-01       Impact factor: 4.755

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.