Literature DB >> 26624887

Non-rigid dual respiratory and cardiac motion correction methods after, during, and before image reconstruction for 4D cardiac PET.

Tao Feng1, Jizhe Wang, George Fung, Benjamin Tsui.   

Abstract

Respiratory motion (RM) and cardiac motion (CM) degrade the quality and resolution in cardiac PET scans. We have developed non-rigid motion estimation methods to estimate both RM and CM based on 4D cardiac gated PET data alone, and compensate the dual respiratory and cardiac (R&C) motions after (MCAR), during (MCDR), and before (MCBR) image reconstruction. In all three R&C motion correction methods, attenuation-activity mismatch effect was modeled by using transformed attenuation maps using the estimated RM. The difference of using activity preserving and non-activity preserving models in R&C correction was also studied. Realistic Monte Carlo simulated 4D cardiac PET data using the 4D XCAT phantom and accurate models of the scanner design parameters and performance characteristics at different noise levels were employed as the known truth and for method development and evaluation. Results from the simulation study suggested that all three dual R&C motion correction methods provide substantial improvement in the quality of 4D cardiac gated PET images as compared with no motion correction. Specifically, the MCDR method yields the best performance for all different noise levels compared with the MCAR and MCBR methods. While MCBR reduces computational time dramatically but the resultant 4D cardiac gated PET images has overall inferior image quality when compared to that from the MCAR and MCDR approaches in the 'almost' noise free case. Also, the MCBR method has better noise handling properties when compared with MCAR and provides better quantitative results in high noise cases. When the goal is to reduce scan time or patient radiation dose, MCDR and MCBR provide a good compromise between image quality and computational times.

Entities:  

Mesh:

Year:  2015        PMID: 26624887     DOI: 10.1088/0031-9155/61/1/151

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Cardiac and Respiratory Motion Correction for Simultaneous Cardiac PET/MR.

Authors:  Christoph Kolbitsch; Mark A Ahlman; Cynthia Davies-Venn; Robert Evers; Michael Hansen; Devis Peressutti; Paul Marsden; Peter Kellman; David A Bluemke; Tobias Schaeffter
Journal:  J Nucl Med       Date:  2017-02-09       Impact factor: 10.057

2.  Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR.

Authors:  Yoann Petibon; Nicolas J Guehl; Timothy G Reese; Behzad Ebrahimi; Marc D Normandin; Timothy M Shoup; Nathaniel M Alpert; Georges El Fakhri; Jinsong Ouyang
Journal:  Phys Med Biol       Date:  2016-12-20       Impact factor: 3.609

3.  4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT.

Authors:  Wenyuan Qi; Yongyi Yang; Chao Song; Miles N Wernick; P Hendrik Pretorius; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2017-04-04       Impact factor: 10.048

4.  Data-Driven Gross Patient Motion Detection and Compensation: Implications for Coronary 18F-NaF PET Imaging.

Authors:  Martin Lyngby Lassen; Jacek Kwiecinski; Sebastien Cadet; Damini Dey; Chengjia Wang; Marc R Dweck; Daniel S Berman; Guido Germano; David E Newby; Piotr J Slomka
Journal:  J Nucl Med       Date:  2018-11-15       Impact factor: 10.057

5.  Adjoint image warping using multivariate splines with application to four-dimensional computed tomography.

Authors:  Jens Renders; Jan Sijbers; Jan De Beenhouwer
Journal:  Med Phys       Date:  2021-08-18       Impact factor: 4.506

6.  Triple-gated motion and blood pool clearance corrections improve reproducibility of coronary 18F-NaF PET.

Authors:  Martin Lyngby Lassen; Jacek Kwiecinski; Damini Dey; Sebastien Cadet; Guido Germano; Daniel S Berman; Philip D Adamson; Alastair J Moss; Marc R Dweck; David E Newby; Piotr J Slomka
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-08-05       Impact factor: 9.236

7.  MR-based motion correction for cardiac PET parametric imaging: a simulation study.

Authors:  Rong Guo; Yoann Petibon; Yixin Ma; Georges El Fakhri; Kui Ying; Jinsong Ouyang
Journal:  EJNMMI Phys       Date:  2018-02-01

8.  Comparison of two elastic motion correction approaches for whole-body PET/CT: motion deblurring vs gate-to-gate motion correction.

Authors:  Stefanie Pösse; Florian Büther; Dirk Mannweiler; Inki Hong; Judson Jones; Michael Schäfers; Klaus Peter Schäfers
Journal:  EJNMMI Phys       Date:  2020-03-30
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.