Literature DB >> 14765051

Long-term evaluation of sandblasted and acid-etched implants used as orthodontic anchors in dogs.

Musa Aldikaçti1, Gökhan Açikgöz, Tamer Türk, Paolo Trisi.   

Abstract

The aim of this study was the clinical, radiographic, and histologic evaluation of the tissue surrounding SLA (sandblasted and acid-etched) implants loaded with a continuous and constant force for 52 weeks, after a healing period of 6 weeks, after implant insertion. SLA implants were placed in the maxilla of 3 dogs and the mandible of 5 dogs after a 12-week healing period after extraction. Abutments were attached to the 6 test implants (2 in the maxilla, 4 in the mandible). Superelastic nickel-titanium coil springs were activated between the SLA implants and the canines, producing a force of 200 g (2 N). Two unloaded implants (1 in the maxilla, 1 in the mandible) served as controls. Histologic analysis showed a corticalization of bone trabeculae, thicker at the loaded than at the unloaded implants. New bone formation at the level of the crest was slightly superior in the test implants. A difference between the tension and compression areas could not be observed in the test implants. The mean bone-implant contact values of the test implants for the maxilla and mandible were 40.23% and 49.33%, respectively. In the control implants, the bone-implant contact value was 67.91% for the maxilla and 49.23% for the mandible. SLA implants can be used as an anchorage unit with confidence, in spite of a short healing period and a prolonged force application. Further studies with different force magnitudes and healing periods are required to clarify the effects of healing period and force magnitude on bone quality and quantity.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14765051     DOI: 10.1016/S0889540603006292

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  4 in total

1.  Does thread design influence relative bone-to-implant contact rate of palatal implants?

Authors:  Britta A Jung; Martin Kunkel; Peter Göllner; Thomas Liechti; Maximilian Moergel; Robert Noelken; Peter Borbély; Heinrich Wehrbein
Journal:  J Orofac Orthop       Date:  2011-07-10       Impact factor: 1.938

2.  Stability of smooth and rough mini-implants: clinical and biomechanical evaluation - an in vivostudy.

Authors:  Giselle Naback Lemes Vilani; Antônio Carlos de Oliveira Ruellas; Carlos Nelson Elias; Cláudia Trindade Mattos
Journal:  Dental Press J Orthod       Date:  2015-10

3.  Long-term follow-up of dental single implants under immediate orthodontic load.

Authors:  Lisiane Meira Palagi; Carlos Eduardo Sabrosa; Eveline C B Gava; Tiziano Baccetti; Jose Augusto M Miguel
Journal:  Angle Orthod       Date:  2010-09       Impact factor: 2.079

4.  Assessing double Acid-etched implants submitted to orthodontic forces and used as prosthetic anchorages in partially edentulous patients.

Authors:  Rugani de Cravero Marta; Ibañez Juan Carlos
Journal:  Open Dent J       Date:  2008-03-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.