Literature DB >> 21300226

Three-dimensional analysis of peri-bone-implant contact of rough-surface miniscrew implants.

Hedeki Ikeda1, P Emile Rossouw, Phillip M Campbell, Elias Kontogiorgos, Elias Kontogirogos, Peter H Buschang.   

Abstract

INTRODUCTION: In this study, we evaluated the effects of surface modifications of miniscrew implants (MSIs) and force application on bone surrounding MSIs.
METHODS: Seven skeletally mature male foxhound dogs were followed for 9 weeks; a randomized split-mouth design was used to compare 21 MSIs with sandblasted, large-grit, and acid-etched (SLA) surfaces and 21 identical machine-surfaced MSIs. MSIs immediately loaded with 200-g nickel-titanium coil springs were compared with unloaded MSIs. Bone volume to total volume ratios of cortical and noncortical bone regions were measured at 6 to 24 μm and 24 to 42 μm from the entire MSI surface using microcomputed tomography with an isotropic resolution of 6 μm.
RESULTS: Clinical success of SLA-surfaced MSIs was 100%, compared with 85.7% for machine-surfaced MSIs. There was significantly (P <0.05) more bone at the coronal aspects of the SLA-surfaced than the machine-surfaced MSIs; the SLA-surfaced MSIs also showed significantly greater decreases in bone between their most coronal and apical aspects. MSIs that were loaded demonstrated significantly (P <0.05) greater decreases in surrounding bone than unloaded MSIs. The amount of bone within 6 to 24 μm of the MSIs was significantly less than that within 24 to 42 μm. Mean placement torque was higher for the SLA-surfaced (42 Ncm) than the machine-surfaced (39 Ncm) MSIs, but the difference was not statistically significant.
CONCLUSIONS: SLA surface treatment and loadings have significant effects on bone surrounding the MSIs; this might be related to higher success rates and greater secondary stability.
Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21300226     DOI: 10.1016/j.ajodo.2010.09.022

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  9 in total

1.  Laser-treated stainless steel mini-screw implants: 3D surface roughness, bone-implant contact, and fracture resistance analysis.

Authors:  He-Kyong Kang; Tien-Min Chu; Paul Dechow; Kelton Stewart; Hee-Moon Kyung; Sean Shih-Yao Liu
Journal:  Eur J Orthod       Date:  2015-04-23       Impact factor: 3.075

2.  Stability of smooth and rough mini-implants: clinical and biomechanical evaluation - an in vivostudy.

Authors:  Giselle Naback Lemes Vilani; Antônio Carlos de Oliveira Ruellas; Carlos Nelson Elias; Cláudia Trindade Mattos
Journal:  Dental Press J Orthod       Date:  2015-10

3.  Is trabecular bone related to primary stability of miniscrews?

Authors:  Mariana Marquezan; Inayá Lima; Ricardo Tadeu Lopes; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza
Journal:  Angle Orthod       Date:  2013-11-18       Impact factor: 2.079

4.  Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study.

Authors:  Danielle Geshay; Phillip Campbell; Larry Tadlock; Emet Schneiderman; Hee-Moon Kyung; Peter Buschang
Journal:  Dental Press J Orthod       Date:  2021-03-22

5.  Improvement of osseointegration of Ti-6Al-4V ELI alloy orthodontic mini-screws through anodization, cyclic pre-calcification, and heat treatments.

Authors:  Changkyun Im; Je-Hyeok Park; Young-Mi Jeon; Jong-Ghee Kim; Yong-Seok Jang; Min-Ho Lee; Woo-Yong Jeon; Jun-Min Kim; Tae-Sung Bae
Journal:  Prog Orthod       Date:  2022-04-04       Impact factor: 3.247

6.  Effect of surface treatment on the mechanical stability of orthodontic miniscrews.

Authors:  Yousef Al-Thomali; Sakeenabi Basha; Roshan Noor Mohamed
Journal:  Angle Orthod       Date:  2022-01-01       Impact factor: 2.079

7.  Orthodontic implants: concepts for the orthodontic practitioner.

Authors:  Carlos Nelson Elias; Antônio Carlos de Oliveira Ruellas; Daniel Jogaib Fernandes
Journal:  Int J Dent       Date:  2012-11-11

8.  Enhanced compatibility and initial stability of Ti6Al4V alloy orthodontic miniscrews subjected to anodization, cyclic precalcification, and heat treatment.

Authors:  Eun-Ju Oh; Thuy-Duong T Nguyen; Seung-Youp Lee; Young-Mi Jeon; Tae-Sung Bae; Jong-Gee Kim
Journal:  Korean J Orthod       Date:  2014-09-25       Impact factor: 1.372

9.  Comparison of mechanical and biological properties of zirconia and titanium alloy orthodontic micro-implants.

Authors:  Hae Won Choi; Young Seok Park; Shin Hye Chung; Min Ho Jung; Won Moon; Sang Hoon Rhee
Journal:  Korean J Orthod       Date:  2017-05-26       Impact factor: 1.372

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.