Literature DB >> 9467987

Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light and scanning electron microscopic analysis in vitro.

M Groten1, S Girthofer, L Pröbster.   

Abstract

The aim of this study was to evaluate the marginal fit of copy-milled Celay In-Ceram crowns after different fabrication steps and to compare light-microscopic with scanning-electron-microscopic data. A master steel die of an upper middle incisor with a shoulder preparation and a rounded inner line angle was used. Impressions were taken to produce 10 working stone dies. One crown per working die was manufactured. The evaluation of the external marginal gap was performed on the master steel die by using a light microscope and a computerized video image analysis system after copy milling (A), glass infiltration (B), and veneering (C). Approximately 3900 readings were taken. In a final series the veneered crowns were measured by using a scanning electron microscope (Cs), yielding approximately 1000 readings. The results obtained were: A mean, 25.1 microm; s.d., 5.1 microm; range, 2.5-76.8 microm: B mean, 20.6 microm; s.d., 2.3 microm; range, 2.5-76.1 microm: C mean, 18.3 microm; s.d., 4.1 microm; range, 2.5-87.2 microm: Cs mean, 23.0 microm; s.d., 7.6 microm; range, 0.0-94.5 microm. The results were statistically evaluated using the t-test. The differences found between the series did not show practical relevance. Therefore, it is concluded that the manufacturing steps after copy milling have no obvious influence on the external marginal gap width. Scanning electron microscopic data seem to confirm the light-microscopic results. Hence, we expect that the Celay In-Ceram method yields a clinically acceptable marginal fit.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9467987     DOI: 10.1046/j.1365-2842.1997.00592.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  12 in total

1.  Fit of cobalt-chromium copings fabricated by the selective laser melting technology and casting method: A comparative evaluation using a profilometer.

Authors:  Koosha Gholamrezaei; Fariborz Vafaee; Behzad Fathi Afkari; Farnaz Firouz; Mozhgan Seif
Journal:  Dent Res J (Isfahan)       Date:  2020-05-23

2.  A comparative study of gold UCLA-type and CAD/CAM titanium implant abutments.

Authors:  Ji-Man Park; Jai-Bong Lee; Seong-Joo Heo; Eun-Jin Park
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

3.  Comparison of Marginal Fit and Fracture Strength of a CAD/CAM Zirconia Crown with Two Preparation Designs.

Authors:  Hamid Jalali; Leyla Sadighpour; Ali Miri; Ahmad Reza Shamshiri
Journal:  J Dent (Tehran)       Date:  2015-12

4.  Marginal Accuracy and Internal Fit of 3-D Printing Laser-Sintered Co-Cr Alloy Copings.

Authors:  Myung-Joo Kim; Yun-Jung Choi; Seong-Kyun Kim; Seong-Joo Heo; Jai-Young Koak
Journal:  Materials (Basel)       Date:  2017-01-23       Impact factor: 3.623

5.  Influence of Intra-Oral Scanner (I.O.S.) on The Marginal Accuracy of CAD/CAM Single Crowns.

Authors:  Francesco Ferrini; Gianpaolo Sannino; Carlo Chiola; Paolo Capparé; Giorgio Gastaldi; Enrico Felice Gherlone
Journal:  Int J Environ Res Public Health       Date:  2019-02-14       Impact factor: 3.390

6.  In vitro comparison of marginal and internal fit between stainless steel crowns and esthetic crowns of primary molars using different luting cements.

Authors:  Sanaa Najeh Al-Haj Ali
Journal:  Dent Res J (Isfahan)       Date:  2019-11-12

7.  In vitro evaluation of the effect of core thickness and fabrication stages on the marginal accuracy of an all-ceramic system.

Authors:  F Farid; H Hajimiragha; R Jelodar; A S Mostafavi; H Nokhbatolfoghahaie
Journal:  J Dent (Tehran)       Date:  2012-09-30

8.  Effect of software version and parameter settings on the marginal and internal adaptation of crowns fabricated with the CAD/CAM system.

Authors:  Ji Suk Shim; Jin Sook Lee; Jeong Yol Lee; Yeon Jo Choi; Sang Wan Shin; Jae Jun Ryu
Journal:  J Appl Oral Sci       Date:  2015-10       Impact factor: 2.698

9.  In Vitro Effect of Porcelain Firing Cycle and Different Thicknesses of IPS E.max CAD Core on Marginal Accuracy of All-Ceramic Restorations.

Authors:  Ezatollah Jalalian; Arash Zarbakhsh; Zahra Mohtashamrad; Nazanin Nourbakhsh; Esmat Jafarpour
Journal:  J Dent (Tehran)       Date:  2015-11

10.  Effect of total occlusal convergence on fit and fracture resistance of zirconia-reinforced lithium silicate crowns.

Authors:  Manal Rahma Alammari; Mohamed Hussein Abdelnabi; Amal Ali Swelem
Journal:  Clin Cosmet Investig Dent       Date:  2018-12-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.