Literature DB >> 26527298

Evaluation of bound and pore water in cortical bone using ultrashort-TE MRI.

Jun Chen1,2, Shawn P Grogan3, Hongda Shao2, Darryl D'Lima3, Graeme M Bydder2, Zhihong Wu1, Jiang Du2.   

Abstract

Bone water exists in different states with the majority bound to the organic matrix and to mineral, and a smaller fraction in 'free' form in the pores of cortical bone. In this study, we aimed to develop and evaluate ultrashort-TE (UTE) MRI techniques for the assessment of T2*, T1 and concentration of collagen-bound and pore water in cortical bone using a 3-T clinical whole-body scanner. UTE MRI, together with an isotope study using tritiated and distilled water (THO-H2O) exchange, as well as gravimetric analysis, were performed on ten sectioned bovine bone samples. In addition, 32 human cortical bone samples were prepared for comparison between the pore water concentration measured with UTE MRI and the cortical porosity derived from micro-computed tomography (μCT). A short T2* of 0.27 ± 0.03 ms and T1 of 116 ± 6 ms were observed for collagen-bound water in bovine bone. A longer T2* of 1.84 ± 0.52 ms and T1 of 527 ± 28 ms were observed for pore water in bovine bone. UTE MRI measurements showed a pore water concentration of 4.7-5.3% by volume and collagen-bound water concentration of 15.7-17.9% in bovine bone. THO-H2O exchange studies showed a pore water concentration of 5.9 ± 0.6% and collagen-bound water concentration of 18.1 ± 2.1% in bovine bone. Gravimetric analysis showed a pore water concentration of 6.3 ± 0.8% and collagen-bound water concentration of 19.2 ± 3.6% in bovine bone. A mineral water concentration of 9.5 ± 0.6% was derived in bovine bone with the THO-H2O exchange study. UTE-measured pore water concentration is highly correlated (R(2) = 0.72, p < 0.0001) with μCT porosity in the human cortical bone study. Both bovine and human bone studies suggest that UTE sequences could reliably measure collagen-bound and pore water concentration in cortical bone using a clinical scanner.
Copyright © 2015 John Wiley & Sons, Ltd.

Entities:  

Keywords:  UTE; bone; bound water; organic matrix; pore water

Mesh:

Substances:

Year:  2015        PMID: 26527298      PMCID: PMC4898891          DOI: 10.1002/nbm.3436

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  43 in total

Review 1.  Bone matters: are density increases necessary to reduce fracture risk?

Authors:  K G Faulkner
Journal:  J Bone Miner Res       Date:  2000-02       Impact factor: 6.741

Review 2.  Bone poroelasticity.

Authors:  S C Cowin
Journal:  J Biomech       Date:  1999-03       Impact factor: 2.712

3.  Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone.

Authors:  Jiang Du; Michael Carl; Mark Bydder; Atsushi Takahashi; Christine B Chung; Graeme M Bydder
Journal:  J Magn Reson       Date:  2010-09-25       Impact factor: 2.229

4.  The influence of water removal on the strength and toughness of cortical bone.

Authors:  Jeffry S Nyman; Anuradha Roy; Xinmei Shen; Rae L Acuna; Jerrod H Tyler; Xiaodu Wang
Journal:  J Biomech       Date:  2006       Impact factor: 2.712

5.  MRI with zero echo time: hard versus sweep pulse excitation.

Authors:  Markus Weiger; Klaas P Pruessmann; Franciszek Hennel
Journal:  Magn Reson Med       Date:  2011-03-04       Impact factor: 4.668

6.  Magnetic resonance imaging assessed cortical porosity is highly correlated with μCT porosity.

Authors:  Won C Bae; Shantanu Patil; Reni Biswas; Shihong Li; Eric Y Chang; Sheronda Statum; Darryl D D'Lima; Christine B Chung; Jiang Du
Journal:  Bone       Date:  2014-06-11       Impact factor: 4.398

7.  Clinically compatible MRI strategies for discriminating bound and pore water in cortical bone.

Authors:  R Adam Horch; Daniel F Gochberg; Jeffry S Nyman; Mark D Does
Journal:  Magn Reson Med       Date:  2012-01-31       Impact factor: 4.668

8.  Characterization of 1H NMR signal in human cortical bone for magnetic resonance imaging.

Authors:  R Adam Horch; Jeffry S Nyman; Daniel F Gochberg; Richard D Dortch; Mark D Does
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

9.  Water content and binding in normal and osteoarthritic human cartilage.

Authors:  H J Mankin; A Z Thrasher
Journal:  J Bone Joint Surg Am       Date:  1975-01       Impact factor: 5.284

10.  Age-related changes in the collagen network and toughness of bone.

Authors:  X Wang; X Shen; X Li; C Mauli Agrawal
Journal:  Bone       Date:  2002-07       Impact factor: 4.398

View more
  13 in total

1.  Magnetization transfer imaging of cortical bone in vivo using a zero echo time sequence in mice at 4.7 T: a feasibility study.

Authors:  Magda Marcon; Markus Weiger; Daniel Keller; Moritz C Wurnig; Christian Eberhardt; Daniel Eberli; Andreas Boss
Journal:  MAGMA       Date:  2016-07-06       Impact factor: 2.310

2.  Fast volumetric imaging of bound and pore water in cortical bone using three-dimensional ultrashort-TE (UTE) and inversion recovery UTE sequences.

Authors:  Jun Chen; Michael Carl; Yajun Ma; Hongda Shao; Xing Lu; Bimin Chen; Eric Y Chang; Zhihong Wu; Jiang Du
Journal:  NMR Biomed       Date:  2016-08-05       Impact factor: 4.044

Review 3.  Cortical Bone Porosity: What Is It, Why Is It Important, and How Can We Detect It?

Authors:  D M L Cooper; C E Kawalilak; K Harrison; B D Johnston; J D Johnston
Journal:  Curr Osteoporos Rep       Date:  2016-10       Impact factor: 5.096

4.  Near infrared spectroscopic assessment of loosely and tightly bound cortical bone water.

Authors:  Ramyasri Ailavajhala; William Querido; Chamith S Rajapakse; Nancy Pleshko
Journal:  Analyst       Date:  2020-04-28       Impact factor: 4.616

5.  Water proton density in human cortical bone obtained from ultrashort echo time (UTE) MRI predicts bone microstructural properties.

Authors:  Saeed Jerban; Yajun Ma; Hyungseok Jang; Behnam Namiranian; Nicole Le; Hoda Shirazian; Mark E Murphy; Jiang Du; Eric Y Chang
Journal:  Magn Reson Imaging       Date:  2020-01-10       Impact factor: 2.546

Review 6.  Quantitative MRI Musculoskeletal Techniques: An Update.

Authors:  Ricardo de Mello; Yajun Ma; Yang Ji; Jiang Du; Eric Y Chang
Journal:  AJR Am J Roentgenol       Date:  2019-04-17       Impact factor: 3.959

7.  Volumetric mapping of bound and pore water as well as collagen protons in cortical bone using 3D ultrashort echo time cones MR imaging techniques.

Authors:  Saeed Jerban; Yajun Ma; Liang Li; Hyungseok Jang; Lidi Wan; Tan Guo; Adam Searleman; Eric Y Chang; Jiang Du
Journal:  Bone       Date:  2019-06-05       Impact factor: 4.398

Review 8.  Ultrashort Echo Time Magnetic Resonance Imaging Techniques: Met and Unmet Needs in Musculoskeletal Imaging.

Authors:  Amir Masoud Afsahi; Yajun Ma; Hyungseok Jang; Saeed Jerban; Christine B Chung; Eric Y Chang; Jiang Du
Journal:  J Magn Reson Imaging       Date:  2021-12-28       Impact factor: 5.119

9.  Can ultrashort-TE (UTE) MRI sequences on a 3-T clinical scanner detect signal directly from collagen protons: freeze-dry and D2 O exchange studies of cortical bone and Achilles tendon specimens.

Authors:  Ya-Jun Ma; Eric Y Chang; Graeme M Bydder; Jiang Du
Journal:  NMR Biomed       Date:  2016-05-05       Impact factor: 4.044

10.  Measurement of bound and pore water T1 relaxation times in cortical bone using three-dimensional ultrashort echo time cones sequences.

Authors:  Jun Chen; Eric Y Chang; Michael Carl; Yajun Ma; Hongda Shao; Bimin Chen; Zhihong Wu; Jiang Du
Journal:  Magn Reson Med       Date:  2016-06-06       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.