MRI with zero echo time: hard versus sweep pulse excitation.

Markus Weiger1, Klaas P Pruessmann, Franciszek Hennel.   

Abstract

Zero echo time can be obtained in MRI by performing radiofrequency (RF) excitation as well as acquisition in the presence of a constant gradient applied for purely frequency-encoded, radial centre-out k-space encoding. In this approach, the spatially nonselective excitation must uniformly cover the full frequency bandwidth spanned by the readout gradient. This can be accomplished either by short, hard RF pulses or by pulses with a frequency sweep as used in the SWIFT (Sweep imaging with Fourier transform) method for improved performance at limited RF amplitudes. In this work, the two options are compared with respect to T2 sensitivity, signal-to-noise ratio (SNR), and SNR efficiency. In particular, the SNR implications of sweep excitation and of initial or periodical acquisition gaps required for transmit-receive switching are investigated. It was found by simulations and experiments that, whereas equivalent in terms of T2 sensitivity, the two techniques differ in SNR performance. With ideal, ungapped simultaneous excitation and acquisition, the sweep approach would yield higher SNR throughout due to larger feasible flip angles. However, acquisition gapping is found to take a significant SNR toll related to a reduced acquisition duty cycle, rendering hard pulse excitation superior for sufficient RF amplitude and also in the short-T2 limit. Copyright &© 2011 Wiley-Liss, Inc.

Mesh:

Year:  2011        PMID: 21381099     DOI: 10.1002/mrm.22799

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  53 in total

1.  Assessment of Silent T1-weighted head imaging at 7 T.

Authors:  Mauro Costagli; Mark R Symms; Lorenzo Angeli; Douglas A C Kelley; Laura Biagi; Andrea Farnetani; Catarina Rua; Graziella Donatelli; Gianluigi Tiberi; Michela Tosetti; Mirco Cosottini
Journal:  Eur Radiol       Date:  2015-08-29       Impact factor: 5.315

2.  Active decoupling of RF coils using a transmit array system.

Authors:  Ali Caglar Özen; Michael Bock; Ergin Atalar
Journal:  MAGMA       Date:  2015-08-05       Impact factor: 2.310

3.  Signal and contrast effects due to T2 decay during k-space readout of UTE (ultrashort TE) sequences.

Authors:  Jing-Tzyh Alan Chiang; Michael Carl; Jiang Du
Journal:  Magn Reson Imaging       Date:  2013-12-07       Impact factor: 2.546

4.  Rapid dual-RF, dual-echo, 3D ultrashort echo time craniofacial imaging: A feasibility study.

Authors:  Hyunyeol Lee; Xia Zhao; Hee Kwon Song; Rosaline Zhang; Scott P Bartlett; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2018-12-18       Impact factor: 4.668

5.  Zero TE MRI for Craniofacial Bone Imaging.

Authors:  A Lu; K R Gorny; M-L Ho
Journal:  AJNR Am J Neuroradiol       Date:  2019-09       Impact factor: 3.825

Review 6.  Magnetic Resonance Imaging of Hard Tissues and Hard Tissue Engineered Bio-substitutes.

Authors:  Simone Mastrogiacomo; Weiqiang Dou; John A Jansen; X Frank Walboomers
Journal:  Mol Imaging Biol       Date:  2019-12       Impact factor: 3.488

Review 7.  Quantitative magnetic resonance imaging of the lumbar intervertebral discs.

Authors:  Dosik Hwang; Sewon Kim; Nirusha A Abeydeera; Sheronda Statum; Koichi Masuda; Christine B Chung; Palanan Siriwanarangsun; Won C Bae
Journal:  Quant Imaging Med Surg       Date:  2016-12

Review 8.  Sodium MRI: methods and applications.

Authors:  Guillaume Madelin; Jae-Seung Lee; Ravinder R Regatte; Alexej Jerschow
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2014-03-07       Impact factor: 9.795

9.  Dual contrast agent for computed tomography and magnetic resonance hard tissue imaging.

Authors:  Manuela Ventura; Yi Sun; Viorel Rusu; Peter Laverman; Paul Borm; Arend Heerschap; Egbert Oosterwijk; Otto C Boerman; John A Jansen; X Frank Walboomers
Journal:  Tissue Eng Part C Methods       Date:  2012-12-21       Impact factor: 3.056

10.  (19)F-MRI for monitoring human NK cells in vivo.

Authors:  Myriam N Bouchlaka; Kai D Ludwig; Jeremy W Gordon; Matthew P Kutz; Bryan P Bednarz; Sean B Fain; Christian M Capitini
Journal:  Oncoimmunology       Date:  2016-02-18       Impact factor: 8.110

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.