Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone.

Jiang Du1, Michael Carl, Mark Bydder, Atsushi Takahashi, Christine B Chung, Graeme M Bydder.   

Abstract

We describe the use of two-dimensional ultrashort echo time (2D UTE) sequences with minimum TEs of 8 μs to image and quantify cortical bone on a clinical 3T scanner. An adiabatic inversion pulse was used for long T(2) water and fat signal suppression. Adiabatic inversion prepared UTE acquisitions with varying TEs were used for T(2) measurement. Saturation recovery UTE acquisitions were used for T(1) measurement. Bone water concentration was measured with the aid of an external reference phantom. UTE techniques were evaluated on cadaveric specimens and healthy volunteers. A signal-to-noise ratio of around 30, contrast-to-noise ratio of around 27/20 between bone and muscle/fat were achieved in tibia in vivo with a nominal voxel size of 0.23 × 0.23 × 6.0 mm(3) in a scan time of 5 min. A mean T(1) of 223 ± 11 ms and mean T(2) of 390 ± 19 μs were found. Mean bone water concentrations of 23.3 ± 1.6% with UTE and 21.7 ± 1.3% with adiabatic inversion prepared UTE sequences were found in tibia in five normal volunteers. The results show that in vivo qualitative and quantitative evaluation of cortical bone is feasible with 2D UTE sequences.
Copyright © 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20980179     DOI: 10.1016/j.jmr.2010.09.013

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  104 in total

1.  Quantitative two-dimensional ultrashort echo time magnetization transfer (2D UTE-MT) imaging of cortical bone.

Authors:  Ya-Jun Ma; Anthony Tadros; Jiang Du; Eric Y Chang
Journal:  Magn Reson Med       Date:  2017-08-03       Impact factor: 4.668

2.  Comparison of optimized soft-tissue suppression schemes for ultrashort echo time MRI.

Authors:  Cheng Li; Jeremy F Magland; Hamidreza Saligheh Rad; Hee Kwon Song; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2011-12-08       Impact factor: 4.668

3.  Transformation in mandibular imaging with sweep imaging with fourier transform magnetic resonance imaging.

Authors:  Ayse Tuba Karagulle Kendi; Samir S Khariwala; Jinjin Zhang; Djaudat S Idiyatullin; Curtis A Corum; Shalom Michaeli; Stefan E Pambuccian; Michael Garwood; Bevan Yueh
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2011-09

4.  Review. The Agfa Mayneord lecture: MRI of short and ultrashort T₂ and T₂* components of tissues, fluids and materials using clinical systems.

Authors:  G M Bydder
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

5.  Meniscal calcifications: morphologic and quantitative evaluation by using 2D inversion-recovery ultrashort echo time and 3D ultrashort echo time 3.0-T MR imaging techniques--feasibility study.

Authors:  Patrick Omoumi; Won C Bae; Jiang Du; Eric Diaz; Sheronda Statum; Graeme M Bydder; Christine B Chung
Journal:  Radiology       Date:  2012-07       Impact factor: 11.105

6.  Thickness of the Meniscal Lamellar Layer: Correlation with Indentation Stiffness and Comparison of Normal and Abnormally Thick Layers by Using Multiparametric Ultrashort Echo Time MR Imaging.

Authors:  Ja-Young Choi; Reni Biswas; Won C Bae; Robert Healey; Michael Im; Sheronda Statum; Eric Y Chang; Jiang Du; Graeme M Bydder; Darryl D'Lima; Christine B Chung
Journal:  Radiology       Date:  2016-02-01       Impact factor: 11.105

7.  To measure T1 of short T2 species using an inversion recovery prepared three-dimensional ultrashort echo time (3D IR-UTE) method: A phantom study.

Authors:  Zhao Wei; Ya-Jun Ma; Hyungseok Jang; Wenhui Yang; Jiang Du
Journal:  J Magn Reson       Date:  2020-04-13       Impact factor: 2.229

8.  Accurate T1 mapping of short T2 tissues using a three-dimensional ultrashort echo time cones actual flip angle imaging-variable repetition time (3D UTE-Cones AFI-VTR) method.

Authors:  Ya-Jun Ma; Xing Lu; Michael Carl; Yanchun Zhu; Nikolaus M Szeverenyi; Graeme M Bydder; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2018-01-03       Impact factor: 4.668

9.  UTE bi-component analysis of T2* relaxation in articular cartilage.

Authors:  H Shao; E Y Chang; C Pauli; S Zanganeh; W Bae; C B Chung; G Tang; J Du
Journal:  Osteoarthritis Cartilage       Date:  2015-09-14       Impact factor: 6.576

10.  Feasibility of using an inversion-recovery ultrashort echo time (UTE) sequence for quantification of glenoid bone loss.

Authors:  Ya-Jun Ma; Justin West; Amin Nazaran; Xin Cheng; Heinz Hoenecke; Jiang Du; Eric Y Chang
Journal:  Skeletal Radiol       Date:  2018-02-02       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.