Literature DB >> 26425981

Proposal for a Simple and Efficient Monthly Quality Management Program Assessing the Consistency of Robotic Image-Guided Small Animal Radiation Systems.

N Patrik Brodin1, Chandan Guha, Wolfgang A Tomé.   

Abstract

Modern pre-clinical radiation therapy (RT) research requires high precision and accurate dosimetry to facilitate the translation of research findings into clinical practice. Several systems are available that provide precise delivery and on-board imaging capabilities, highlighting the need for a quality management program (QMP) to ensure consistent and accurate radiation dose delivery. An ongoing, simple, and efficient QMP for image-guided robotic small animal irradiators used in pre-clinical RT research is described. Protocols were developed and implemented to assess the dose output constancy (based on the AAPM TG-61 protocol), cone-beam computed tomography (CBCT) image quality and object representation accuracy (using a custom-designed imaging phantom), CBCT-guided target localization accuracy and consistency of the CBCT-based dose calculation. To facilitate an efficient read-out and limit the user dependence of the QMP data analysis, a semi-automatic image analysis and data representation program was developed using the technical computing software MATLAB. The results of the first 6-mo experience using the suggested QMP for a Small Animal Radiation Research Platform (SARRP) are presented, with data collected on a bi-monthly basis. The dosimetric output constancy was established to be within ±1 %, the consistency of the image resolution was within ±0.2 mm, the accuracy of CBCT-guided target localization was within ±0.5 mm, and dose calculation consistency was within ±2 s (±3%) per treatment beam. Based on these results, this simple quality assurance program allows for the detection of inconsistencies in dosimetric or imaging parameters that are beyond the acceptable variability for a reliable and accurate pre-clinical RT system, on a monthly or bi-monthly basis.

Entities:  

Mesh:

Year:  2015        PMID: 26425981      PMCID: PMC4602164          DOI: 10.1097/HP.0000000000000323

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  14 in total

1.  A multipurpose quality assurance phantom for the small animal radiation research platform (SARRP).

Authors:  Wilfred Ngwa; Panagiotis Tsiamas; Piotr Zygmanski; G Mike Makrigiorgos; Ross I Berbeco
Journal:  Phys Med Biol       Date:  2012-04-11       Impact factor: 3.609

2.  Deriving Hounsfield units using grey levels in cone beam computed tomography.

Authors:  P Mah; T E Reeves; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2010-09       Impact factor: 2.419

3.  Animal models for medical countermeasures to radiation exposure.

Authors:  Jacqueline P Williams; Stephen L Brown; George E Georges; Martin Hauer-Jensen; Richard P Hill; Amy K Huser; David G Kirsch; Thomas J Macvittie; Kathy A Mason; Meetha M Medhora; John E Moulder; Paul Okunieff; Mary F Otterson; Michael E Robbins; James B Smathers; William H McBride
Journal:  Radiat Res       Date:  2010-04       Impact factor: 2.841

4.  Dosimetric characterization of an image-guided stereotactic small animal irradiator.

Authors:  R Pidikiti; S Stojadinovic; M Speiser; K H Song; F Hager; D Saha; T D Solberg
Journal:  Phys Med Biol       Date:  2011-03-28       Impact factor: 3.609

5.  Characterization of image quality and image-guidance performance of a preclinical microirradiator.

Authors:  R Clarkson; P E Lindsay; S Ansell; G Wilson; S Jelveh; R P Hill; D A Jaffray
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

Review 6.  Small animal radiotherapy research platforms.

Authors:  Frank Verhaegen; Patrick Granton; Erik Tryggestad
Journal:  Phys Med Biol       Date:  2011-05-26       Impact factor: 3.609

7.  Multi-institutional dosimetric and geometric commissioning of image-guided small animal irradiators.

Authors:  P E Lindsay; P V Granton; A Gasparini; S Jelveh; R Clarkson; S van Hoof; J Hermans; J Kaas; F Wittkamper; J-J Sonke; F Verhaegen; D A Jaffray
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

8.  Modality comparison for small animal radiotherapy: a simulation study.

Authors:  Magdalena Bazalova; Geoff Nelson; John M Noll; Edward E Graves
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

9.  Commissioning of a novel microCT/RT system for small animal conformal radiotherapy.

Authors:  Manuel Rodriguez; Hu Zhou; Paul Keall; Edward Graves
Journal:  Phys Med Biol       Date:  2009-05-28       Impact factor: 3.609

10.  A comprehensive system for dosimetric commissioning and Monte Carlo validation for the small animal radiation research platform.

Authors:  E Tryggestad; M Armour; I Iordachita; F Verhaegen; J W Wong
Journal:  Phys Med Biol       Date:  2009-08-18       Impact factor: 3.609

View more
  4 in total

Review 1.  Tumour and normal tissue radiobiology in mouse models: how close are mice to mini-humans?

Authors:  Bridget F Koontz; Frank Verhaegen; Dirk De Ruysscher
Journal:  Br J Radiol       Date:  2016-09-26       Impact factor: 3.039

2.  Stereotactic Body Radiation Therapy Delivery in a Genetically Engineered Mouse Model of Lung Cancer.

Authors:  Shisuo Du; Virginia Lockamy; Lin Zhou; Christine Xue; Justin LeBlanc; Shonna Glenn; Gaurav Shukla; Yan Yu; Adam P Dicker; Dennis B Leeper; You Lu; Bo Lu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-07-21       Impact factor: 7.038

3.  A Model for Precise and Uniform Pelvic- and Limb-Sparing Abdominal Irradiation to Study the Radiation-Induced Gastrointestinal Syndrome in Mice Using Small Animal Irradiation Systems.

Authors:  N Patrik Brodin; Anna Velcich; Chandan Guha; Wolfgang A Tomé
Journal:  Dose Response       Date:  2017-01-04       Impact factor: 2.658

4.  Design and commissioning of an image-guided small animal radiation platform and quality assurance protocol for integrated proton and x-ray radiobiology research.

Authors:  Michele M Kim; Peyton Irmen; Khayrullo Shoniyozov; Ioannis I Verginadis; Keith A Cengel; Costantinos Koumenis; James M Metz; Lei Dong; Eric S Diffenderfer
Journal:  Phys Med Biol       Date:  2019-07-04       Impact factor: 3.609

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.