Literature DB >> 21444969

Dosimetric characterization of an image-guided stereotactic small animal irradiator.

R Pidikiti1, S Stojadinovic, M Speiser, K H Song, F Hager, D Saha, T D Solberg.   

Abstract

Small animal irradiation provides an important tool used by preclinical studies to assess and optimize new treatment strategies such as stereotactic ablative radiotherapy. Characterization of radiation beams that are clinically and geometrically scaled for the small animal model is uniquely challenging for orthovoltage energies and minute field sizes. The irradiator employs a commercial x-ray device (XRAD 320, Precision x-ray, Inc.) with a custom collimation system to produce 1-10 mm diameter beams and a 50 mm reference beam. Absolute calibrations were performed using the AAPM TG-61 methodology. Beam's half-value layer (HVL) and timer error were measured with an ionization chamber. Percent depth dose (PDD), output factors (OFs) and off-axis ratios were measured using radiochromic film, a diode and a pinpoint ionization chamber at 19.76 and 24.76 cm source-to-surface distance (SSD). PDD measurements were also compared with Monte Carlo (MC) simulations. In-air and in-water absolute calibrations for the reference 50 mm diameter collimator at 19.76 cm SSD were measured as 20.96 and 20.79 Gy min(-1), respectively, agreeing within 0.8%. The HVL at 250 kVp and 15 mAs was measured to be 0.45 mm Cu. The reference field PDD MC simulation results agree with measured data within 3.5%. PDD data demonstrate typical increased penetration with increasing field size and SSD. For collimators larger than 5 mm in diameter, OFs measured using film, an ion chamber and a diode were within 3% agreement.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21444969     DOI: 10.1088/0031-9155/56/8/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  24 in total

1.  Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques.

Authors:  Joseph Newton; Mark Oldham; Andrew Thomas; Yifan Li; John Adamovics; David G Kirsch; Shiva Das
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Systematic study of target localization for bioluminescence tomography guided radiation therapy.

Authors:  Jingjing Yu; Bin Zhang; Iulian I Iordachita; Juvenal Reyes; Zhihao Lu; Malcolm V Brock; Michael S Patterson; John W Wong; Ken Kang-Hsin Wang
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

3.  An experimental model-based exploration of cytokines in ablative radiation-induced lung injury in vivo and in vitro.

Authors:  Zhen-Yu Hong; Kwang Hyun Song; Joo-Heon Yoon; Jaeho Cho; Michael D Story
Journal:  Lung       Date:  2015-03-07       Impact factor: 2.584

4.  Bioluminescence Tomography-Guided Radiation Therapy for Preclinical Research.

Authors:  Bin Zhang; Ken Kang-Hsin Wang; Jingjing Yu; Sohrab Eslami; Iulian Iordachita; Juvenal Reyes; Reem Malek; Phuoc T Tran; Michael S Patterson; John W Wong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-12-14       Impact factor: 7.038

5.  Proposal for a Simple and Efficient Monthly Quality Management Program Assessing the Consistency of Robotic Image-Guided Small Animal Radiation Systems.

Authors:  N Patrik Brodin; Chandan Guha; Wolfgang A Tomé
Journal:  Health Phys       Date:  2015-11       Impact factor: 1.316

6.  Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters.

Authors:  Steven T Bache; Titania Juang; Matthew D Belley; Bridget F Koontz; John Adamovics; Terry T Yoshizumi; David G Kirsch; Mark Oldham
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

7.  Key role for neutrophils in radiation-induced antitumor immune responses: Potentiation with G-CSF.

Authors:  Tsuguhide Takeshima; Laurentiu M Pop; Aaron Laine; Puneeth Iyengar; Ellen S Vitetta; Raquibul Hannan
Journal:  Proc Natl Acad Sci U S A       Date:  2016-09-20       Impact factor: 11.205

8.  Correlations of noninvasive BOLD and TOLD MRI with pO2 and relevance to tumor radiation response.

Authors:  Rami R Hallac; Heling Zhou; Rajesh Pidikiti; Kwang Song; Strahinja Stojadinovic; Dawen Zhao; Timothy Solberg; Peter Peschke; Ralph P Mason
Journal:  Magn Reson Med       Date:  2013-06-27       Impact factor: 4.668

9.  Investigating end-to-end accuracy of image guided radiation treatment delivery using a micro-irradiator.

Authors:  L J Rankine; J Newton; S T Bache; S K Das; J Adamovics; D G Kirsch; M Oldham
Journal:  Phys Med Biol       Date:  2013-10-18       Impact factor: 3.609

10.  A sparse orthogonal collimator for small animal intensity-modulated radiation therapy part I: Planning system development and commissioning.

Authors:  Kaley Woods; Dan Nguyen; Ryan Neph; Dan Ruan; Daniel O'Connor; Ke Sheng
Journal:  Med Phys       Date:  2019-11-04       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.