Literature DB >> 26395021

Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation.

Peter Bernhardt1, Christoph Rodewald2, Julia Seeger2, Birgid Gonska2, Dominik Buckert2, Michael Radermacher2, Vinzenz Hombach2, Wolfgang Rottbauer2, Jochen Wöhrle2.   

Abstract

BACKGROUND: Correct sizing of the aortic annulus in aortic valve stenosis is crucial for successful transcatheter aortic valve implantation (TAVI). Multislice computed tomography (MSCT) seems to be most promising imaging modality for this pre-interventional diagnostic work-up, but has the disadvantage of exposing mostly co-morbid patients to iodine and nephrotoxic contrast agents. To establish a useful sizing method for TAVI without the use of contrast media, we compared measurements of a non-contrast magnetic resonance imaging (MRI) technique with MSCT serving as the reference standard.
METHODS: Fifty-two patients who underwent TAVI were previously examined with MSCT and MRI, respectively. MRI examination included a 3D steady-state free-precession sequence covering the entire ascending aorta. Perimeter and area of the aortic root were analyzed by two blinded readers in consensus using a dedicated software. Decisions for Sapien 3 valve size of both imaging modalities were compared using the mean derived annulus diameter.
RESULTS: Mean age of the study cohort was 82.2 ± 4.9 years, log EuroScore was 25.2 ± 4.8 %. Mean aortic annulus perimeter as measured by MSCT was 76.7 ± 6.9 mm. MRI yielded a mean perimeter of 76.5 ± 6.7 mm with a good correlation coefficient (r = 0.93, p < 0.0001). Decision for valve size showed good correlation between both imaging modalities (r = 0.94, p < 0.0001).
CONCLUSION: In conclusion, non-contrast MRI shows good correlation to MSCT in the assessment of the aortic annulus and valve sizing. This non-contrast technique might be a reasonable alternative for aortic root sizing before TAVI without the use of nephrotoxic contrast agents, especially in patients with severely reduced kidney function.

Entities:  

Keywords:  Magnetic resonance imaging; Transcatheter aortic valve implantation

Mesh:

Year:  2015        PMID: 26395021     DOI: 10.1007/s00392-015-0920-6

Source DB:  PubMed          Journal:  Clin Res Cardiol        ISSN: 1861-0684            Impact factor:   5.460


  26 in total

1.  Assessment of the aortic annulus by multislice computed tomography, contrast aortography, and trans-thoracic echocardiography in patients referred for transcatheter aortic valve implantation.

Authors:  Apostolos Tzikas; Carl J Schultz; Nicolo Piazza; Adrian Moelker; Nicolas M Van Mieghem; Rutger-Jan Nuis; Robert-Jan van Geuns; Marcel L Geleijnse; Patrick W Serruys; Peter P T de Jaegere
Journal:  Catheter Cardiovasc Interv       Date:  2011-04-14       Impact factor: 2.692

Review 2.  Echocardiography for transcatheter aortic valve implantation.

Authors:  Derek Chin
Journal:  Eur J Echocardiogr       Date:  2009-01

3.  Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice.

Authors:  Helmut Baumgartner; Judy Hung; Javier Bermejo; John B Chambers; Arturo Evangelista; Brian P Griffin; Bernard Iung; Catherine M Otto; Patricia A Pellikka; Miguel Quiñones
Journal:  J Am Soc Echocardiogr       Date:  2009-01       Impact factor: 5.251

4.  Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful?

Authors:  Carl J Schultz; Adriaan Moelker; Nicolo Piazza; Apostolos Tzikas; Amber Otten; Rutger J Nuis; Lisan A Neefjes; Robert J van Geuns; Pim de Feyter; Gabriel Krestin; Patrick W Serruys; Peter P T de Jaegere
Journal:  Eur Heart J       Date:  2009-12-07       Impact factor: 29.983

5.  Quantification of aortic valve area at 256-slice computed tomography: comparison with transesophageal echocardiography and cardiac catheterization in subjects with high-grade aortic valve stenosis prior to percutaneous valve replacement.

Authors:  Oliver Klass; Matthew J Walker; Mark E Olszewski; Johannes Bahner; Sebastian Feuerlein; Martin H K Hoffmann; Alexandra Lang
Journal:  Eur J Radiol       Date:  2010-09-15       Impact factor: 3.528

Review 6.  Nephrotoxicity related to contrast media.

Authors:  K J Berg
Journal:  Scand J Urol Nephrol       Date:  2000-10

7.  A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Modification of Diet in Renal Disease Study Group.

Authors:  A S Levey; J P Bosch; J B Lewis; T Greene; N Rogers; D Roth
Journal:  Ann Intern Med       Date:  1999-03-16       Impact factor: 25.391

8.  Aortic annulus and ascending aorta: comparison of preoperative and periooperative measurement in patients with aortic stenosis.

Authors:  Michal Smíd; Jirí Ferda; Jan Baxa; Jakub Cech; Tomás Hájek; Boris Kreuzberg; Richard Rokyta
Journal:  Eur J Radiol       Date:  2009-02-23       Impact factor: 3.528

9.  Nephrogenic systemic fibrosis: a population study examining the relationship of disease development to gadolinium exposure.

Authors:  Aneet Deo; Mitchell Fogel; Shawn E Cowper
Journal:  Clin J Am Soc Nephrol       Date:  2007-02-07       Impact factor: 8.237

10.  Cardiovascular magnetic resonance for the assessment of patients undergoing transcatheter aortic valve implantation: a pilot study.

Authors:  Alessio La Manna; Alessandra Sanfilippo; Davide Capodanno; Antonella Salemi; Gesualdo Polizzi; Wanda Deste; Glauco Cincotta; Alessandra Cadoni; Anna Marchese; Michele Figuera; Gian P Ussia; Rosetta Pittalà; Carmelo Privitera; Corrado Tamburino
Journal:  J Cardiovasc Magn Reson       Date:  2011-12-27       Impact factor: 5.364

View more
  12 in total

1.  Multi-parametric approach to predict prosthetic valve size using CMR and clinical data: insights from SAVR.

Authors:  Federico E Mordini; Conor F Hynes; Richard L Amdur; Jeffrey Panting; Dominic A Emerson; Jason Morrissette; Erin Goheen-Thomas; Michael D Greenberg; Gregory D Trachiotis
Journal:  Int J Cardiovasc Imaging       Date:  2021-03-10       Impact factor: 2.357

2.  Late migration of Edwards SAPIEN 3 transcatheter heart valves: mechanisms and transcatheter treatment options for a rare phenomenon.

Authors:  Tobias Rheude; Costanza Pellegrini; Jonathan Michel; Christian Thilo; Michael Joner; Albert Markus Kasel
Journal:  Clin Res Cardiol       Date:  2018-06-13       Impact factor: 5.460

3.  Cardiovascular magnetic resonance as a reliable alternative to cardiovascular computed tomography and transesophageal echocardiography for aortic annulus valve sizing.

Authors:  Riccardo Faletti; Marco Gatti; Stefano Salizzoni; Laura Bergamasco; Rodolfo Bonamini; Domenica Garabello; Walter Grosso Marra; Michele La Torre; Mara Morello; Simona Veglia; Paolo Fonio; Mauro Rinaldi
Journal:  Int J Cardiovasc Imaging       Date:  2016-04-27       Impact factor: 2.357

4.  Is MRI equivalent to CT in the guidance of TAVR? A pilot study.

Authors:  Agnes Mayr; Gert Klug; Sebastian J Reinstadler; Hans-Josef Feistritzer; Martin Reindl; Christian Kremser; Christof Kranewitter; Nikolaos Bonaros; Guy Friedrich; Gudrun Feuchtner; Bernhard Metzler
Journal:  Eur Radiol       Date:  2018-05-07       Impact factor: 5.315

5.  Predictors for permanent pacemaker implantation in patients undergoing transfemoral aortic valve implantation with the Edwards Sapien 3 valve.

Authors:  Birgid Gonska; Julia Seeger; Mirjam Keßler; Alexander von Keil; Wolfgang Rottbauer; Jochen Wöhrle
Journal:  Clin Res Cardiol       Date:  2017-03-10       Impact factor: 5.460

6.  Patient-specific registration of 3D CT angiography (CTA) with X-ray fluoroscopy for image fusion during transcatheter aortic valve implantation (TAVI) increases performance of the procedure.

Authors:  I Vernikouskaya; W Rottbauer; J Seeger; B Gonska; V Rasche; Jochen Wöhrle
Journal:  Clin Res Cardiol       Date:  2018-02-16       Impact factor: 5.460

7.  Accuracy of cardiac magnetic resonance generated 3D models of the aortic annulus compared to cardiovascular computed tomography generated 3D models.

Authors:  Marco Gatti; Aurelio Cosentino; Erik Cura Stura; Laura Bergamasco; Domenica Garabello; Giovanni Pennisi; Mattia Puppo; Stefano Salizzoni; Simona Veglia; Ottavio Davini; Mauro Rinaldi; Paolo Fonio; Riccardo Faletti
Journal:  Int J Cardiovasc Imaging       Date:  2020-05-30       Impact factor: 2.357

8.  Longitudinal strain assessed by cardiac magnetic resonance correlates to hemodynamic findings in patients with severe aortic stenosis and predicts positive remodeling after transcatheter aortic valve replacement.

Authors:  Dominik Buckert; Maciej Cieslik; Raid Tibi; Michael Radermacher; Volker Rasche; Peter Bernhardt; Vinzenz Hombach; Wolfgang Rottbauer; Jochen Wöhrle
Journal:  Clin Res Cardiol       Date:  2017-08-14       Impact factor: 5.460

9.  Non-contrast MRI protocol for TAVI guidance: quiescent-interval single-shot angiography in comparison with contrast-enhanced CT.

Authors:  Mathias Pamminger; Gert Klug; Christof Kranewitter; Martin Reindl; Sebastian J Reinstadler; Benjamin Henninger; Christina Tiller; Magdalena Holzknecht; Christian Kremser; Axel Bauer; Werner Jaschke; Bernhard Metzler; Agnes Mayr
Journal:  Eur Radiol       Date:  2020-04-22       Impact factor: 5.315

10.  Dynamic contrast-enhanced MRI versus 18F-FDG PET/CT: Which is better in differentiation between malignant and benign solitary pulmonary nodules?

Authors:  Feng Feng; Fulin Qiang; Aijun Shen; Donghui Shi; Aiyan Fu; Haiming Li; Mingzhu Zhang; Ganlin Xia; Peng Cao
Journal:  Chin J Cancer Res       Date:  2018-02       Impact factor: 5.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.