Is MRI equivalent to CT in the guidance of TAVR? A pilot study.

Agnes Mayr1, Gert Klug2, Sebastian J Reinstadler2, Hans-Josef Feistritzer2, Martin Reindl2, Christian Kremser1, Christof Kranewitter1, Nikolaos Bonaros3, Guy Friedrich2, Gudrun Feuchtner1, Bernhard Metzler4.   

Abstract

OBJECTIVES: To compare a comprehensive cardiovascular magnetic resonance imaging (MRI) protocol with contrast-enhanced computed tomography angiography (CTA) for guidance in transcatheter aortic valve replacement (TAVR) evaluation. METHODS AND
RESULTS: Non-contrast three-dimensional (3D) 'whole heart' MRI imaging for aortic annulus sizing and measurements of coronary ostia heights, contrast-enhanced MRI angiography (MRA) for evaluation of transfemoral routes as well as aortoiliofemoral-CTA were performed in 16 patients referred for evaluation of TAVR. Aortic annulus measurements by MRI and CTA showed a very strong correlation (r=0.956, p<0.0001; effective annulus area for MRI 430±74 vs. 428±78 mm2 for CTA, p=0.629). Regarding decision for valve size there was complete consistency between MRI and CTA. Moreover, vessel luminal diameters and angulations of aortoiliofemoral access as measured by MRA and CTA showed overall very strong correlations (r= 0.819 to 0.996, all p<0.001), the agreement of minimal vessel diameter between the two modalities revealed a bias of 0.02 mm (upper and lower limit of agreement: 1.02 mm and -0.98 mm).
CONCLUSIONS: In patients referred for TAVR, MRI measurements of aortic annulus and minimal aortoiliofemoral diameters showed good to excellent agreement. Decisions based on MRI measurements regrading prosthesis sizing and transfemoral access would not have modified TAVR-strategy as compared to a CTA-based choice. KEY POINTS: • 'Whole heart' MRI and CTA measurements of aortic annulus correlate very strongly. • MRI- and CTA-based prostheses sizing are in excellent agreement. • MRA and CTA equally guide TAVR access strategy.

Entities:  

Keywords:  Aortic valve; CT angiography; Cardiac imaging techniques; Contrast media; Magnetic resonance angiography

Mesh:

Year:  2018        PMID: 29736853     DOI: 10.1007/s00330-018-5386-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  43 in total

1.  Cardiac index after acute ST-segment elevation myocardial infarction measured with phase-contrast cardiac magnetic resonance imaging.

Authors:  Gert Klug; Sebastian Johannes Reinstadler; Hans-Josef Feistritzer; Christian Kremser; Johannes P Schwaiger; Martin Reindl; Johannes Mair; Silvana Müller; Agnes Mayr; Wolfgang-Michael Franz; Bernhard Metzler
Journal:  Eur Radiol       Date:  2015-09-18       Impact factor: 5.315

2.  Nephrogenic systemic fibrosis and contrast medium-induced nephropathy: a choice between the devil and the deep blue sea for patients with reduced renal function?

Authors:  K Lind Ramskov; H S Thomsen
Journal:  Acta Radiol       Date:  2009-11       Impact factor: 1.990

3.  Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement.

Authors:  Marco Barbanti; Tae-Hyun Yang; Josep Rodès Cabau; Corrado Tamburino; David A Wood; Hasan Jilaihawi; Phillip Blanke; Raj R Makkar; Azeem Latib; Antonio Colombo; Giuseppe Tarantini; Rekha Raju; Ronald K Binder; Giang Nguyen; Melanie Freeman; Henrique B Ribeiro; Samir Kapadia; James Min; Gudrun Feuchtner; Ronen Gurtvich; Faisal Alqoofi; Marc Pelletier; Gian Paolo Ussia; Massimo Napodano; Fabio Sandoli de Brito; Susheel Kodali; Bjarne L Norgaard; Nicolaj C Hansson; Gregor Pache; Sergio J Canovas; Hongbin Zhang; Martin B Leon; John G Webb; Jonathon Leipsic
Journal:  Circulation       Date:  2013-06-07       Impact factor: 29.690

4.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

5.  Oversizing in transcatheter aortic valve replacement, a commonly used term but a poorly understood one: dependency on definition and geometrical measurements.

Authors:  Philipp Blanke; Alexander B Willson; John G Webb; Stephan Achenbach; Nicolo Piazza; James K Min; Gregor Pache; Jonathon Leipsic
Journal:  J Cardiovasc Comput Tomogr       Date:  2014-01-12

6.  The impact of integration of a multidetector computed tomography annulus area sizing algorithm on outcomes of transcatheter aortic valve replacement: a prospective, multicenter, controlled trial.

Authors:  Ronald K Binder; John G Webb; Alexander B Willson; Marina Urena; Nicolaj C Hansson; Bjarne L Norgaard; Philippe Pibarot; Marco Barbanti; Eric Larose; Melanie Freeman; Eric Dumont; Chris Thompson; Miriam Wheeler; Robert R Moss; Tae-hyun Yang; Sergio Pasian; Cameron J Hague; Giang Nguyen; Rekha Raju; Stefan Toggweiler; James K Min; David A Wood; Josep Rodés-Cabau; Jonathon Leipsic
Journal:  J Am Coll Cardiol       Date:  2013-05-15       Impact factor: 24.094

7.  Benefits of high-pitch 128-slice dual-source computed tomography for planning of transcatheter aortic valve implantation.

Authors:  Fabian Plank; Guy Friedrich; Thomas Bartel; Silvana Mueller; Nikolaos Bonaros; Anneliese Heinz; Andrea Klauser; Fabiola Cartes-Zumelzu; Michael Grimm; Gudrun Feuchtner
Journal:  Ann Thorac Surg       Date:  2012-08-24       Impact factor: 4.330

Review 8.  Nephrogenic systemic fibrosis and gadolinium-based contrast media: updated ESUR Contrast Medium Safety Committee guidelines.

Authors:  Henrik S Thomsen; Sameh K Morcos; Torsten Almén; Marie-France Bellin; Michele Bertolotto; Georg Bongartz; Olivier Clement; Peter Leander; Gertraud Heinz-Peer; Peter Reimer; Fulvio Stacul; Aart van der Molen; Judith A W Webb
Journal:  Eur Radiol       Date:  2012-08-04       Impact factor: 5.315

Review 9.  Lower extremity arterial disease: multidetector CT angiography meta-analysis.

Authors:  Majanka H Heijenbrok-Kal; Marc C J M Kock; M G Myriam Hunink
Journal:  Radiology       Date:  2007-09-11       Impact factor: 11.105

Review 10.  MRI in Chronic Aortic Dissection: A Systematic Review and Future Directions.

Authors:  Andrew G Sherrah; Stuart M Grieve; Richmond W Jeremy; Paul G Bannon; Michael P Vallely; Rajesh Puranik
Journal:  Front Cardiovasc Med       Date:  2015-02-19
View more
  7 in total

1.  Multi-parametric approach to predict prosthetic valve size using CMR and clinical data: insights from SAVR.

Authors:  Federico E Mordini; Conor F Hynes; Richard L Amdur; Jeffrey Panting; Dominic A Emerson; Jason Morrissette; Erin Goheen-Thomas; Michael D Greenberg; Gregory D Trachiotis
Journal:  Int J Cardiovasc Imaging       Date:  2021-03-10       Impact factor: 2.357

2.  Aortic roots assessment by an automated three-dimensional transesophageal echocardiography: an intra-individual comparison.

Authors:  Minghui Zhang; Linyuan Wan; Kun Liu; Weichun Wu; Hui Li; Yuan Wang; Bin Lu; Hao Wang
Journal:  Int J Cardiovasc Imaging       Date:  2019-07-11       Impact factor: 2.357

Review 3.  Transcatheter aortic valve replacement with a focus on transcarotid: a review of the current literature.

Authors:  Issa Pour-Ghaz; Joel Raja; Mahmoud Bayoumi; Theodore Manolukas; Rami N Khouzam; Uzoma N Ibebuogu
Journal:  Ann Transl Med       Date:  2019-09

Review 4.  Preoperative TAVR Planning: How to Do It.

Authors:  Rodrigo Petersen Saadi; Ana Paula Tagliari; Eduardo Keller Saadi; Marcelo Haertel Miglioranza; Carisi Anne Polanczyck
Journal:  J Clin Med       Date:  2022-05-05       Impact factor: 4.964

5.  Non-contrast MRI protocol for TAVI guidance: quiescent-interval single-shot angiography in comparison with contrast-enhanced CT.

Authors:  Mathias Pamminger; Gert Klug; Christof Kranewitter; Martin Reindl; Sebastian J Reinstadler; Benjamin Henninger; Christina Tiller; Magdalena Holzknecht; Christian Kremser; Axel Bauer; Werner Jaschke; Bernhard Metzler; Agnes Mayr
Journal:  Eur Radiol       Date:  2020-04-22       Impact factor: 5.315

6.  Cardiac magnetic resonance imaging versus computed tomography to guide transcatheter aortic valve replacement: study protocol for a randomized trial (TAVR-CMR).

Authors:  Gert Klug; Sebastian Reinstadler; Felix Troger; Magdalena Holzknecht; Martin Reindl; Christina Tiller; Ivan Lechner; Priscilla Fink; Mathias Pamminger; Christian Kremser; Hanno Ulmer; Axel Bauer; Bernhard Metzler; Agnes Mayr
Journal:  Trials       Date:  2022-09-02       Impact factor: 2.728

Review 7.  Clinical and Technical Challenges of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation.

Authors:  Pier Pasquale Leone; Fabio Fazzari; Francesco Cannata; Jorge Sanz-Sanchez; Antonio Mangieri; Lorenzo Monti; Ottavia Cozzi; Giulio Giuseppe Stefanini; Renato Bragato; Antonio Colombo; Bernhard Reimers; Damiano Regazzoli
Journal:  Front Cardiovasc Med       Date:  2021-06-04
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.