| Literature DB >> 28808772 |
Dominik Buckert1, Maciej Cieslik2, Raid Tibi2, Michael Radermacher2, Volker Rasche2, Peter Bernhardt2, Vinzenz Hombach2, Wolfgang Rottbauer2, Jochen Wöhrle2.
Abstract
AIMS: To assess left-ventricular strain parameters before and after transcatheter aortic valve replacement (TAVR) by feature tracking cardiac magnetic resonance imaging (FT CMR) and to correlate the findings to hemodynamic state and left-ventricular remodeling. METHODS ANDEntities:
Keywords: Cardiac magnetic resonance imaging; Cardiac mechanics; Severe aortic stenosis; Strain imaging; Transcatheter aortic valve replacement
Mesh:
Substances:
Year: 2017 PMID: 28808772 PMCID: PMC5760599 DOI: 10.1007/s00392-017-1153-7
Source DB: PubMed Journal: Clin Res Cardiol ISSN: 1861-0684 Impact factor: 5.460
Baseline characteristics
| Total cohort ( | ||
|---|---|---|
| Age (years) | 78.8 ± 5.9 | Mean ± SD |
| Sex (men) | 15 (50.0) | N, (%) |
| BMI (kg/m2) | 27.4 ± 5.1 | Mean ± SD |
| Hypertension | 29 (96.7) | N, (%) |
| Hyperlipoproteinaemia | 24 (80.0) | N, (%) |
| Diabetes mellitus | 11 (36.7) | N, (%) |
| Coronary artery disease | 24 (80.0) | N, (%) |
| Atrial fibrillation | 13 (43.3) | N, (%) |
| NYHA class | 3.1 ± 0.6 | Mean ± SD |
| EURO score II | 5.4 ± 3.8 | Mean ± SD |
| STS-Score | 4.7 ± 3.0 | Mean ± SD |
BMI body mass index, NYHA New York Heart Association, STS Society of Thoracic Surgeons
Hemodynamic characteristics
| Total cohort | HF/HG | LF/LG | PLF/LG | |
|---|---|---|---|---|
| LVEF (%) | 56.7 ± 18.4 | 65.0 ± 13.2 | 26.3 ± 7.2 | 63.7 ± 8.4 |
| LVEDVi (ml/m2) | 79.5 ± 30.9 | 73.0 ± 21.3 | 123.3 ± 36.1 | 64.8 ± 12.43 |
| LVSVi (ml/m2) | 40.0 ± 8.3 | 45.3 ± 6.4 | 30.4 ± 4.9 | 32.72 ± 5.9 |
| Ci | 2.9 ± 0.66 | 3.3 ± 0.58 | 2.5 ± 0.71 | 2.7 ± 0.47 |
| RVEF (%) | 60.4 ± 12.2 | 67.8 ± 8.1 | 46.8 ± 13.0 | 60.3 ± 9.7 |
| RVEDVi (ml/m2) | 68.7 ± 15.4 | 62.6 ± 11.0 | 80.5 ± 22.6 | 68.3 ± 12.5 |
| MPG (mmHg) | 34.0 ± 14.6 | 47.5 ± 16.1 | 28.8 ± 9.5 | 26.1 ± 5.7 |
| AVA (cm2) | 0.69 ± 0.21 | 0.56 ± 0.13 | 0.80 ± 0.14 | 0.77 ± 0.22 |
| LVEDP (mmHg) | 20.7 ± 6.2 | 19.7 ± 6.7 | 26.5 ± 2.1 | 20.3 ± 6.1 |
Values are mean ± standard deviation
AVA aortic valve area, CI cardiac index, HF/HG high-flow/high-gradient aortic stenosis, LF/LG low-flow/low-gradient aortic stenosis, LVEDVi left-ventricular end-diastolic volume index, LVEDP left-ventricular end-diastolic pressure, LVEF left ventricular ejection fraction, LVSVi left-ventricular stroke volume index, MPG mean pressure gradient, PLF/LG paradoxical low-flow/low-gradient aortic stenosis, RVEDVI right-ventricular end-diastolic volume index, RVEF right-ventricular ejection fraction
Presence of coronary artery disease and late gadolinium enhancement
| Total cohort | HF/HG | LF/LG | PLF/LG | |
|---|---|---|---|---|
| Presence of Coronary artery disease ( | 24 (80.0) | 8 (72.7) | 5 (83.3) | 11 (84.6) |
| Late gadolinium enhancement ( | 14 (46.7) | 7 (54.5) | 6 (100) | 2 (15.4) |
| Consistent with fibrosis | 11 (36.7) | 5 (45.5) | 4 (66.7) | 2 (15.4) |
HF/HG high-flow/high-gradient aortic stenosis, LF/LG low-flow/low-gradient aortic stenosis, PLF/LG paradoxical low-flow/low-gradient aortic stenosis
Intraclass correlation and inter-reader agreement of longitudinal strain
| Intra-class correlation | Inter-reader agreement | |
|---|---|---|
| Longitudinal | ||
| Peak strain (%) | 0.94 | Kappa: 0.94; |
| Peak strain rate systolic (%/s) | 0.90 | Kappa: 0.83 |
| Peak displacement (mm) | 0.98 | Kappa: 0.98 |
| Peak velocity (mm/s) | 0.98 | Kappa: 0.95 |
CI confidence interval
Strain imaging before transcatheter aortic valve replacement
| Total cohort | HF/HG | LG/LG | PLF/LG | Controls | |
|---|---|---|---|---|---|
| Longitudinal | |||||
| Peak strain (%) | −12.61 ± 5.58 | −12.67 ± 4.60 | −5.06 ± 4.25 | −15.80 ± 4.56 | −15.91 ± 1.96 |
| Peak strain rate systolic (%/s) | 79.20 ± 37.39 | 97.79 ± 47.93 | 42.69 ± 14.53 | 81 ± 28.48 | 91.38 ± 23.54 |
| Peak displacement (mm) | 3.62 ± 1.42 | 3.61 ± 1.21 | 2.40 ± 1.91 | 3.98 ± 1.21 | 3.30 ± 1.28 |
| Peak velocity (mm/s) | 35.30 ± 16.01 | 47.24 ± 16.63 | 25.33 ± 9.63 | 29.76 ± 9.98 | 42.02 ± 12.39 |
| Radial | |||||
| Peak strain (%) | 29.20 ± 13.50 | 30.94 ± | 12.05 ± 7.37 | 35.65 ± 11.76 | 47.16 ± 11.37 |
| Peak strain rate systolic (%/s) | 221.46 ± 95.62 | 248.46 ± | 91.69 ± 64.79 | 258.51 ± 68.33 | 291.15 ± 93.07 |
| Peak displacement (mm) | 4.03 ± 2.03 | 4.00 ± 2.17 | 2.07 ± 1.31 | 4.96 ± 1.56 | 6.84 ± 0.87 |
| Peak velocity (mm/s) | 26.46 ± 10.79 | 29.95 ± 10.98 | 12.53 ± 6.10 | 29.95 ± 6.65 | 40.77 ± 8.61 |
| Circumferential | |||||
| Peak strain (%) | −10.37 ± 9.02 | −9.13 ± 11.78 | −3.00 ± 4.47 | −14.83 ± 4.75 | −18.46 ± 2.41 |
| Peak strain rate systolic (%/s) | −93.02 ± 48.78 | −97.36 ± 48.24 | −27.00 ± 18.24 | −119.84 ± 26.38 | −105.13 ± 25.40 |
| Peak displacement (deg) | 0.04 ± 1.79 | −0.36 ± 2.06 | 0.73 ± 1.61 | 0.03 ± 1.70 | −0.11 ± 0.15 |
| Peak velocity (deg/s) | −4.49 ± 21.91 | −4.91 ± 23.80 | 6.22 ± 21.84 | −9.08 ± 20.23 | −1.29 ± 0.95 |
Values are mean ± standard deviation
HF/HG high-flow/high-gradient aortic stenosis, LF/LG low-flow/low-gradient aortic stenosis, PLF/LG paradoxical low-flow/low-gradient aortic stenosis
Fig. 1Global longitudinal strain and global longitudinal velocity in dependency of hemodynamic subgroups. In comparison to the HF/HG group, a significant reduction of strain and velocity could be observed for the LF/LG group. Patients in the PLF/LG group showed strain comparable to the HF/HG group but a reduction in velocity similar to the LF/LG group (HF/HG high-flow/high-gradient aortic stenosis, LF/LG low-flow/low-gradient aortic stenosis, PLF/LG paradoxical low-flow/low-gradient aortic stenosis)
Fig. 2Receiver operating characteristics analysis. By the use of a cutoff criterion of ≤32.946 mm/s, a ‘low-flow’ state could be predicted by global longitudinal velocity with a sensitivity of 75% and a specificity of 80%
Changes after transcatheter aortic valve replacement in dependency of hemodynamic situation
| Before TAVR | After TAVR | Change (paired differences) | ||
|---|---|---|---|---|
| High-flow/high-gradient aortic stenosis | ||||
| NYHA class | 3.4 ± 0.55 | 2.0 ± 0.71 | −1.4 ± 0.89 | 0.025 |
| Left-ventricular ejection fraction (%) | 66.8 ± 12.41 | 69.3 ± 8.77 | 2.5 ± 13.47 | 0.572 |
| NT-proBNP (pg/ml) | 3823.9 ± 3966.3 | 2669.7 ± 2163.26 | 1154.2 ± 2769.6 | 0.277 |
| Low-flow/low-gradient aortic stenosis | ||||
| NYHA class | 3.31 ± 0.48 | 2.08 ± 0.64 | −1.23 ± 0.83 | 0.004 |
| Left-ventricular ejection fraction (%) | 26.3 ± 7.23 | 35.5 ± 13.69 | 9.17 ± 7.22 | 0.027 |
| NT-proBNP (pg/ml) | 6822.5 ± 4844.9 | 6580.3 ± 6146.5 | 242.3 ± 2381.3 | 0.852 |
| Paradoxical low-flow/low-gradient aortic stenosis | ||||
| NYHA class | 3.29 ± 0.49 | 2.29 ± 4.9 | −1.00 ± 0.82 | 0.0018 |
| Left-ventricular ejection fraction (%) | 63.69 ± 8.40 | 65.77 ± 9.68 | 2.08 ± 5.51 | 0.200 |
| NT-proBNP (pg/ml) | 2056.6 ± 2474.7 | 2253.0 ± 2033.0 | −196.3 ± 1086.9 | 0.650 |
Values are reported as mean ± standard deviation or n, %
TAVR transcatheter aortic valve replacement
Changes in strain after transcatheter aortic valve replacement in dependency of hemodynamic situation
| Before TAVR | After TAVR | Change (paired differences) |
| |
|---|---|---|---|---|
| High-flow/high-gradient aortic stenosis | ||||
| Longitudinal | ||||
| Peak strain (%) | −12.67 ± 4.60 | −15.46 ± 5.61 | −3.55 ± 4.58 | 0.048 |
| Peak strain rate systolic (%/s) | 101.56 ± 52.72 | 105.49 ± 24.36 | 3.93 ± 72.99 | 0.876 |
| Peak displacement (mm) | 3.44 ± 1.17 | 5.09 ± 1.46 | 1.65 ± 1.63 | 0.016 |
| Peak velocity (mm/s) | 46.31 ± 18.07 | 47.33 ± 12.87 | 1.02 ± 25.48 | 0.907 |
| Low-flow/low-gradient aortic stenosis | ||||
| Longitudinal | ||||
| Peak strain (%) | −5.06 ± 4.25 | −8.02 ± 3.28 | −2.96 ± 2.73 | 0.045 |
| Peak strain rate systolic (%/s) | 41.98 ± 16.68 | 50.43 ± 15.83 | 8.45 ± 21.01 | 0.480 |
| Peak displacement (mm) | 2.40 ± 1.91 | 2.72 ± 1.79 | 0.32 ± 1.39 | 0.601 |
| Peak velocity (mm/s) | 25.33 ± 9.63 | 37.13 ± 11.64 | 11.80 ± 10.65 | 0.042 |
| Paradoxical low-flow/low-gradient aortic stenosis | ||||
| Longitudinal | ||||
| Peak strain (%) | −15.80 ± 4.56 | −14.85 ± 5.30 | 0.96 ± 4.94 | 0.498 |
| Peak strain rate systolic (%/s) | 81.0 ± 28.48 | 88.65 ± 21.56 | 7.65 ± 21.55 | 0.224 |
| Peak displacement (mm) | 3.98 ± 1.21 | 3.16 ± 1.31 | −0.82 ± 1.34 | 0.046 |
| Peak velocity (mm/s) | 29.76 ± 9.98 | 29.47 ± 9.58 | −0.29 ± 9.45 | 0.914 |
Values are reported as mean ± standard deviation or n, %
TAVR transcatheter aortic valve replacement