| Literature DB >> 26389058 |
Zahra Dalili Kajan1, Jalil Khademi2, Ahmad Alizadeh3, Yasamin Babaei Hemmaty4, Zahra Atrkar Roushan5.
Abstract
PURPOSE: This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging.Entities:
Keywords: Artifacts; Magnetic Resonance Imaging; Orthodontic Brackets; Orthodontic Wires
Year: 2015 PMID: 26389058 PMCID: PMC4574053 DOI: 10.5624/isd.2015.45.3.159
Source DB: PubMed Journal: Imaging Sci Dent ISSN: 2233-7822
Fig. 1The brackets are bonded with composite onto the teeth for performing magnetic resonance imaging.
Fig. 2A and B. The mandible is fixed in the starch mixture.
The scanning parameters of the different sequences of magnetic resonance imaging.
SET1: spin-echo T-weighted, FSET2: fast spin-echo T-weighted, FLAIR: fluid-attenuated inversion recovery.
Fig. 3Axial (A) and coronal (B) images reveal various measurements of signal-void areas along the X-, Y-, and Z-axes detected in the different imaging sequences for American-brand brackets with NiTi wire.
Fig. 4Axial (A) and coronal (B) views reveal the various measurements of the signal-void areas along the X-, Y-, and Z-axes in the different imaging sequences for Dentaurum-brand brackets with nickel titanium wires.
Fig. 5Axial (A) and coronal (B) views show the various measurements of the signal-void areas found along the X-, Y-, and Z-axes in the different imaging sequences for Masel-brand brackets with stainless steel wires.
Comparison of the mean signal void values measured along the X-, Y-, and Z-axes for four brands of orthodontic brackets with either SS or NiTi wires.
*One-way analysis of variation, †Degrees of freedom, SS: stainless steel, NiTi: nickel titanium, SD: standard deviation, NS: not significant, S: significant.
Comparison of the mean signal void values measured along the X-, Y-, and Z-axes for four brands of orthodontic brackets with SS wires.
*One-way analysis of variation, †Degrees of freedom, SS: stainless steel. SD: standard deviation, NS: not significant, S: significant.
Comparison of the mean signal void values measured along the X-, Y-, and Z-axes for four brands of orthodontic brackets with NiTi wires.
*One-way analysis of variation, †Degrees of freedom, NiTi: nickel titanium, SD: standard deviation, NS: not significant, S: significant.
The mean values of signal-free zones measured along the X-, Y-, and Z-axes depending on whether SS or NiTi wires were used with a given orthodontic bracket.
*Independent t-test, †T-value, SS: stainless steel, NiTi, nickel titanium, SD: standard deviation, NS: not significant, S: significant.
Comparison of the mean values of signal-free zones between the nickel-containing brackets (Dentaurum, 3M and American) and those that were nickel-free (Masel).
*One-way analysis of variation, †Degrees of freedom, SD: standard deviation, NS: not significant, S: significant.